DOE-HDBK-1169-2003, Nuclear Air Cleaning Handbook, Chapter 7, Glovebox Filtration
Functional areas: Gloveboxes, HEPA Filters, Design Philosophies
This handbook draws from many special technical areas, each of which requires years of education and practice to master. The authors do not intend to make the reader an "instant expert" in the overall subject or in any of the disciplines of the contributors. The 4th edition of the Nuclear Air Cleaning Handbook succeeds three previous editions: ERDA 76-21, Nuclear Air Cleaning Handbook (1976); ORNL/NSIC-65, Design, Construction and Testing of High-Efficiency Air Filtration Systems for Nuclear Applications (1970); and NSIC-13, Filters, Sorbents, and Air Cleaning Systems as Engineered Safeguards in Nuclear Installations (1966). It benefits from over 25 years of industry experience since the previous edition was published. This revision updates the information provided in ERDA 76-21 and incorporates current thinking as provided by manufacturers, subject matter experts from the DOE complex and members of the ASME Committee on Nuclear Air and Gas Treatment (ASME AG-1 Committee). Chapters have been added on History, Fire Protection, and Occupational Safety and Health.
Related To:
Version history and related documents
Related documents
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Chapter 8, Testing
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Chapter 9, Special Application Requirements
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Chapter 10, Fire Protection
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Chapter 11, Occupational Safety and Health
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Appendix A, Care and Handling of HEPA Filters
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Appendix B, Receiving Inspection Direction and Checklist
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Appendix C, Determination of HEPA Filter Life
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Chapter 1, History of the Development of Air Cleaning Technology in the Nuclear Industry
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Chapter 2, System Considerations
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Chapter 3, Filters for the Nuclear Industry
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Chapter 4, Housing Design and Layout
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Chapter 5, External Components
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook, Chapter 6, Small Air Cleaning Units
- DOE-HDBK-1169-2003Nuclear Air Cleaning Handbook (Introduction) (Part 1 of 15, links to all Parts)
Document text
Text extracted from the attached file. Refer to the original document for the authoritative version.
Section 1
7-1
CHAPTER 7
GLOVEBOX FILTRATION
7.1 Introduction
Gloveboxes are enclosures that enable operators in various industries (e.g., nuclear, biological,
pharmaceutical, microelectronics) to use their hands to manipulate hazardous materials through gloves
without exposure to themselves or subsequent unfiltered release of the material to the environment. In the
nuclear industry, gloveboxes provide primary confinement for radioactive material handling and process
protection and are used to handle a diverse range of chemical, oxygen-sensitive, pyrophoric, hazardous, and
nuclear materials. [Note: There are many other factors, (e.g., seismic, shielding, etc.,) that could impact
glovebox filtration design and operation. Secondary confinement may be provided by the room or building
where the gloveboxes are located.]
Ventilation is the heart of the glovebox system. Nuclear materials requiring handling inside a glovebox
usually present little or no penetrating radiation hazard, but emit radioactive particles that could be dangerous
if inhaled. Gloveboxes prevent operators from inhaling radioactive particles as they work with various
nuclear materials and help provide a clean, controlled, safe working environment. For glovebox ventilation to
be effective, however, proper design pressures and flow criteria must be maintained. Glovebox pressures
range from mostly negative (for confinement) to positive pressure environments (for process protection).
Failure to maintain correct operational pressures or to follow established operational procedures could render
a glovebox both ineffective and unsafe.
This chapter discusses filtration of air or other gases associated with glovebox ventilation. The discussions in
this chapter are not meant to be application-specific, but are intended to provide general information that
may be useful in glovebox design and operations (i.e., specifics related to activities such as plutonium or
beryllium operations will affect glovebox ventilation design).
7.1.1 Glovebox Descriptions
To understand the importance of glovebox filtration, a clear understanding of glovebox characteristics and
functions is necessary.
A glovebox (Figure 7.1) is a windowed, airtight (sometimes gas-tight) enclosure that may be capable of
positive or negative internal pressure. It is equipped with one or more flexible gloves for manipulation of
materials and performance of operations inside the enclosure from the outside, uncontaminated environment.
Figure 7.2 defines and lists characteristics of gloveboxes, with a focus on their use in the nuclear industry.
Originally, many gloveboxes were vendor-designed, so the designs were proprietary. As a result, many older
boxes have unique ventilation designs. Today, professional societies such as the American Glovebox Society
(AGS) have documentation such as AGS-G001, Guidelines for Gloveboxes,1 which was written by Government
employees and vendors who work with, manufacture, and design gloveboxes. This document contains useful
information on subjects ranging from the need for a glovebox to related quality assurance acceptance
programs.
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-2
Secondary HEPA
Filter Housing
Inlet Purification
Unit
Push-Through
Filter Housing
Manifold
Exhaust
(Hard Pipe)
Pressure
Gauge
Light
Fixture
Gloveports
Window
Bag-Out
Port
Section 2
There are still manufacturers who produce “research-type” gloveboxes in the United States today. These
boxes can be used by some U.S. Department of Energy (DOE) facilities, but it is not advisable to use them
for nuclear activities, as most are not equipped with a method for safely changing the high-efficiency
particulate air (HEPA) filters and may not meet the provisions of this chapter. [Note: The HEPA filters used
on some of these gloveboxes do not meet the recommendations provided in Chapter 2 or American Society
of Mechanical Engineers (ASME) AG-1.]2
Ongoing development of gloveboxes for use by the nuclear industry has resulted in many changes through
the years. Gloveboxes have evolved from the somewhat standard sizes to larger custom systems containing
all of the process-related equipment. The larger gloveboxes cited in this Handbook have some unique
characteristics. Some are as large as 150 feet long, 4 feet deep, and 15 feet tall. See Figure 7.3 for a portion
of the type of glovebox. Note the numerous gloveports which allow access to all points in the box. Their
ventilation design includes side-access filter housings (see Chapter 4) instead of the designs described later in
this chapter. Other design philosophies place drive motors, equipment, and electrical devices externally,
thereby reducing maintenance, heat loading, size, and disposal costs. Seals are used to pass drives and
electrical controls through the glovebox pressure boundary. In some cases, the design philosophy has been
Figure 7.1 – Typical Glovebox Showing Major Features
DOE-HDBK-1169-2003 Chapter 7
7-3
to size the glovebox for a specific process to minimize volume and service requirements. In all cases,
ergonomics and confinement are critical to the performance of daily operations and routine maintenance.
Gloveboxes generally have several common characteristics. They are often no deeper than 26 inches (as far
as most arms can reach—it is desirable to be able to reach most areas of a glovebox). If deeper space is
needed, a dual side-access design may be selected. These contain one or more safety glass, laminated-glass, or
polymer viewing windows located on at least one side. Gloveports (window-mounted or in the stainless steel
shell) are usually available in multiples of two at various locations in the glovebox walls. Interior workspace is
reserved for primary operating purposes on the box floor between the gloveports and within reach of a
gloved hand. Remote handling capabilities, other than tool extensions for the gloved hand, are usually not
provided.
Gloveboxes are normally kept at a negative pressure of 0.3 to 0.5 inches water gauge (in.wg) relative to their
surroundings. The maximum safe operating differential pressure between the interior and exterior of the box
is usually less than 4 in.wg; greater differential pressure may damage or rupture a glove or window, causing
subsequent loss of confinement. Operators experience fatigue when pressures inside a glovebox are greater
than 0.5 in.wg, and performance of intricate tasks becomes tedious. Material and HEPA filter transfers
between glovebox interiors and exteriors are commonly made through a bagging port which, although time-
consuming and user-dependent, is still the safest practical way of maintaining confinement. New versions of
this technology use a banding system. Other material transfers use rapid transfer ports (RTPs), which allow
simple docking from glovebox to glovebox. This is a reliable method of maintaining confinement as long as
the seals are maintained and undamaged. [Note: Transfers of powders can egress past the seals if exposed.
Such powders should be contained in a secondary container and the seals protected during operations.]
Gloveboxes with RTPs are still equipped with bagging ports for filter changes and waste disposal.
Section 3
HEPA filter installations must adapt to limitations while still providing reliable service. Hybrid glovebox-
shielded cells, vacuum gloveboxes, room-high gloveboxes, glovebox “trains,” etc., are often encountered, and
all require reliable filter installations.
Figure 7.2 – Characteristics of Gloveboxes
Protection of Raw Material
Process or Product
Exclude Unwanted Portion of
Surroundings from Material
Protection of External
Biosphere from Material
Exclude Dangerous Portion
of Material from Surroundings
Glove Box
Air and
Special
Atmosphere
Vacuum
Hot-Cell
Canyon
Cave
Fume
Hood
Clean
Bench
With Bare or
Surgical Gloved Hands
Through Box-attached Gloves
with Surgical-gloved Hands
By Remote
Manipulation
Airflow from Filters
Must be Laminar to
Exclude Particulates
from Workspace
Physical Boundary Completely Encloses Material
within Primary Workspace and Excludes
Interaction Between this Space and Surroundings
to the Degree Necessary to Perform Work Safely
Airflow Toward
Workspace Away from
Personnel (Exhausted
out After Treatment)
InertAir Vacuum Partial Inert Oxygen Delete Dry Air
Recirculated
(After Purification)
Released to Outside
(After Treatment)
Glovebox is space for work to be
performed while excluding unwanted
effects of surroundings on material or
materials on surroundings. In nuclear
industry, gloveboxes generally protect
the surroundings.
1. Definition
2. Purpose
3. Reason
Necessary
4. How
Accomplished
5. Related
Workspaces
6. Workspace
Handling
7. Exclusion
Method
8. Glovebox
Atmosphere
9. Destination of
Box Exhaust
An enclosure with connected gloves to allow people on the outside to handle material within workspace.
To process material and control interaction of surroundings and material.
GLOVEBOX COMMENT
Glovebox atmospheres other than air
are used to protect material or prevent
it from becoming less stable.
Physical boundary may be sheet metal
walls, glass windows, rubber gloves,
gaskets, pipe service connections, or
inlet - or exhaust - filter media.
In vacuum gloveboxes, material is
handled remotely under vacuum, through
boxgloves when vacuum relieved.
Vacuum glovebox evacuated for duration
of special operations, otherwise an
alternate atmosphere is used (row 8).
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-4
Special atmospheres such as
inert gas and dry air are often
used in gloveboxes for fire
suppression and for oxygen-
sensitive and/or moisture-
sensitive materials and
processes. Gas purification
systems are commonly used
in conjunction with inert
environments to maintain
environmental control.
These units purify and dry
the environment to prevent
consumption of large
volumes of inert gas and
desiccant. It is important to
protect these devices from
contamination because they
constantly recirculate the
volumes of the gloveboxes
they serve.
7.1.2 Importance of Glovebox Ventilation and Filtration
Operations conducted in gloveboxes often provide the elements for unstable conditions (e.g., fire and
pressurization). A properly designed and operated glovebox ventilation system minimizes these instabilities
as well as the possibility of an accidental release of airborne radioactive material. Room air is a safe glovebox
environment for many applications. On the other hand, operations with pyrophoric materials such as
plutonium or the presence of reactive gases such as hydrogen may require a special environment (e.g., low
oxygen, inert gas, and moisture control).
Section 4
For air-atmosphere boxes, ventilation at relatively low flow rates provides sufficient dilution of the limited
combustible volatiles found in well-operated gloveboxes. The correct airflow volume, along with the proper
location of supply and exhaust filters, minimizes the likelihood of fire while providing sufficient dilution to
prevent the buildup of explosive gases. Good glovebox ventilation dictates that HEPA filters are operated at
their designed airflow [cubic feet per minute (cfm)]. It is important that HEPA filters are tested and certified
at the manufacturers’ rated airflow. As airflow increases, efficiency decreases.
Normal air changes through a glovebox remove some of the heat generated by equipment inside the box and
help maintain reasonable working temperatures for the operator. However, this convective cooling may be
insufficient to remove all of the process heat generated in the box, and auxiliary cooling or higher airflow
volume may be required. Most glovebox ventilation systems include some form of pressure relief and
adequate pressure control to maintain proper pressure differentials between the glovebox and its
surroundings. If a glove should tear or accidentally come off, there should be an assured, sufficient ingress of
air through the gloveport to prevent egress of contamination until the port is closed. This safety feature is
inherent if the glovebox ventilation is designed and operated properly. Pyrophoric operations, however,
should have appropriate safeguards to prevent air intake from starting a severe reaction.
Figure 7.3 – Glovebox with Multiple Gloveports to
Facilitate Access
DOE-HDBK-1169-2003 Chapter 7
7-5
Proper instrumentation should be provided to warn of inlet/exhaust filter blockage and loss of
pressure/confinement. Pressure gauge/transducer line filters should be used to protect this instrumentation.
HEPA filters have been used on gloveboxes to contain radioactive materials since the early days of the
nuclear industry. History has shown that, as a rule, they have been adequate; however, submicron-sized
particles of some materials can pass through HEPA filters. In such cases, it is critical to have knowledge of
the material properties. Technology should be used to help determine the type of filters and efficiencies that
can be used for a proper filtration system.
In summary, the glovebox ventilation and filtration system must be capable of reliable performance to assure
glovebox operators that they may safely operate the box without fear of exposure to airborne contamination
to themselves, other facility personnel, and the environment.
7.2 Design of Glovebox Ventilation Systems
The principals of glovebox confinement are basic. Airflow of 125 ± 25 feet per minute (fpm) through a
breached (8-inch diameter) gloveport will maintain confinement. This is an inherent (defined as “real time, at
the moment of failure”) safety feature that should be incorporated into the glovebox system. Most nuclear,
biological, and pharmaceutical facilities in the United States are designed to provide this capability (within a
range of 10 percent). It is important to understand how this is achieved.
Section 5
A glovebox is basically a closed volume. When the blower unit draws air (negative side) from the box, the
box is under negative pressure. The filters help regulate this pressure. Filters are essentially controlled leaks
that allow airflow through them while trapping the particulates they are designed to filter out. The inlet filter
establishes the actual glovebox working pressure, while the exhaust filter system establishes the inherent
safety feature. It is therefore critical for the exhaust filter to be properly engineered into the system to
perform its inherent duty. When a gloveport breach occurs, by design the inlet filter is bypassed and the
breached gloveport becomes the inlet.
The air change rate is an important consideration for all gloveboxes. As glovebox volume increases, airflow
should increase. Nonetheless, the inherent safety feature of 125 ± 25 fpm through a gloveport must be
maintained. For normal operations, flow rate is based on the dilution of evolved combustible or corrosive
gases and heat dissipation, as well as prior experience. The exhaust capability must be sufficient to provide
safety under postulated abnormal conditions, including the gloveport breach. In certain other applications,
the exhaust capability must be sufficient to provide safe access for planned activities.
Operating personnel, industrial hygienists, and radiation specialists can assist the designer in establishing
realistic requirements, particularly when an existing system is being replaced or revised. The types and
quantities of materials to be used inside the box and their toxicity and state (wet slurry, dry powder, etc.) must
be considered when establishing the air exchange rate and velocity. When exposed radioactive material is
handled inside a glovebox, the box becomes the primary confinement. When handling nuclear and
pyrophoric materials, consideration should be given to whether pressure inside the glovebox should be
positive or negative. A positive-pressured glovebox provides a motive force for airborne contamination to
leak from the box into the secondary confinement (the room or facility). Negative pressure inside the box is
essential to maintain glovebox confinement when working with radioactive material. It is not usually
acceptable to design a normal operating condition that allows a primary confinement area to be positive to
the secondary confinement area. However, in a unique or unusual application where an inert environment is
used to control fire and explosion, the box may be slightly positive or even neutral, and the facility becomes
the primary confinement. This suggests the need for a secondary confinement and also flags the need for
personal protective equipment and appropriate procedures to protect the worker. The designer must design
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-6
for failure (i.e., using the worse case scenario) to predict the consequences of a glovebox failure. The
designer also must consider test and acceptance criteria.
7.2.1 Blowers
The blower is the motive force that provides the pressure and airflow requirements in a glovebox. Related
principles are covered in Chapter 5. Glovebox blower requirements have different or additional
requirements. Generally, the airflow is very low (approximately 35 cfm) for most applications. [Note: This is
true for gloveboxes with volumes of less than 100 cubic feet (ft3), and does not factor in heat or gas loading.]
Blower selection must account not only for the breached gloveport scenario, but also for corrosive gases and
filter loading.
Section 6
The typical airflow for most gloveboxes is 35 cfm, assuming a standard 8-inch-diameter gloveport. A typical
cartridge filter rated at 35 cfm will have an approximate 0.8-in.wg clean static pressure drop. When both inlet
and exhaust filters are installed, the total pressure differential for the filter requirements is 1.6 inches water
column (in.wc). [This does not factor in the ductwork and inlet configurations.] The filter loading factor for
most facilities is sometimes greater than double the initial static pressure. In this situation, the blower must
be able to perform within its blower curve at 1.6 to 3.2 in.wc and still produce 35 cfm. This is a higher
pressure and lower flow than used for most fan and blower applications. A regenerative blower is often used
in this application. These blowers operate similar to pumps in that the clearance between the blower wheel
and blower housing is very small. If the blower is to service more than one glovebox, the blower should be
sized to handle the additional requirements. Exhaust manifolds should use dedicated lines for each glovebox
to prevent transfer of heat from one glovebox to another.
Regardless of the type of blower or manufacturer, the required airflow and pressure requirement must be
attained for safe operation of a glovebox. Another criterion for blower selection and design is selection of a
blower that does not exceed the pressure limits of the glovebox. Depending on their size, most stainless steel
gloveboxes with 7-gauge walls are designed and tested at -4 in.wg. Exceeding this pressure may cause damage
to the glovebox windows, seals, and shell. If the blower exceeds this limit, the glovebox should be equipped
with a pressure relief device.
“Pressure recovery” is a term that evolved from quick insertion and removal of operators’ arms into and out
of the gloves. Although the blower will deal with most of the volumetric changes caused by glove movement,
loading the exhaust filter will prevent the blower from quick recovery. Exhaust filter and gloveport sizes also
influence recovery. This is the reason for maintaining the inherent safety feature at the design phase of a
glovebox project. If larger gloveports (greater than 8-inch-diameter) are selected, the need for additional
airflow must be engineered. Site-specific filter housings and filters may not address the need for increased
airflow.
Blower location depends on several variables in glovebox applications. If a scale or other vibration-sensitive
device is used in the glovebox, the blower should be isolated from the glovebox shell with vibration isolators
and a flexible inlet/exhaust connection. Although this works in most applications, some may require remote
location of the blower away from the glovebox. Blower noise should be considered to prevent annoying the
workers. Noise levels should be kept to less than 80 decibels A-weighted (dBA).
7.2.2 Filter Housings
It is imperative that the filter housing on a glovebox be designed to function correctly. It should incorporate
designs for safety, ergonomics, and reliable operation. Filter change-out should be simple and should
maintain a safe level of confinement. The design should prevent any form of contamination from reaching
the downstream ductwork or secondary confinement (the facility). The design should satisfy the ergonomic
DOE-HDBK-1169-2003 Chapter 7
7-7
Section 7
requirements of filter changes and allow the operator to perform the operation safely (without exposure or
injury). In most installations, the filter housings are located in areas of the glovebox that are awkward to
reach. A top-mounted filter housing should be located as close to the front of the glovebox as possible and
should be aligned with a gloveport. Although DOE-STD-1066, Fire Protection Design Criteria,3 suggests locating
the exhaust filter housing to a lower position in the glovebox for fire purposes, this may cause a loss of
confinement in some applications. Process activities and materials could block the exhaust filter. Without
the exhaust filter airflow, it would be difficult to maintain confinement. The filter housings on gloveboxes
differ from most filter housings in that they are very small due to ergonomic limitations and low airflow
requirements. Changing a glovebox filter is difficult because it must be performed through a gloveport with
limited operator movement. Use of larger filters should be avoided because they are difficult to handle safely
inside a glovebox without special tooling.
7.2.2.1 Types
The types of filter housings selected for use on gloveboxes have always been application-specific. See
Figure 7.4 for bag-in/bag-out port which allows for equipment removal. As many nuclear facilities function
under different directives, filter housings have evolved to suit their respective applications. Early gloveboxes
often had externally mounted HEPA filters. Because of the potential for spreading contamination during
filter changes, this practice should be avoided.
Internal filter installations range in design, however, and all have a mechanism to restrain the filter (a HEPA
filter) and a sealing mechanism. These mechanisms also vary; however, it is critical that the mechanism be
free of sharp edges that
can easily cut gloves.
Cracks and crevices
should be kept to a
minimum since the
location makes cleaning
difficult. Filter housing
construction typically
requires clean, smooth
finishes to allow cleanup
of contaminated or
potentially contaminated
areas. Experience has
shown that areas exposed
to contamination can be
impossible to clean. The
rougher the surface of
the housing, the more
difficult it is to clean.
Valves, located to the
outside, are used to isolate the spent filters during filter changes. Most applications use a prefilter to protect
the HEPA filter, as well as a fire screen when there is a potential for fire. Although diverse, the many
prefilter and fire screen designs should meet the requirements imposed in DOE-STD-1066.3
The last basic requirement is a means and method to remove the contaminated filter from the glovebox. The
most common method is the bag-in/bag-out method. Push-through filter housings differ in that they hold
the standby filter in the filter housing. (See Figure 7.5 for push-through filter housing). The filter is a
cartridge type with chevron seals located at the inlet and the exhaust of the round cartridge filter. One of its
advantages is that it is designed to maintain confinement during a filter change. A new filter displaces the
spent filter as it is pushed through. The old filter and spacer are displaced to the inside of the glovebox. The
Figure 7.4 Bag-In/Bag-Out Port for Equipment Removal
Bag-In Bag-Out
Port
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-8
Section 8
inner pipe “tube” of the housing is honed to obtain a smooth, round surface. The chevron seal, which is
larger than the internal diameter of the tube, creates the seal. Although this system has been used with great
success, seal quality and tube finish are critical to its proper operation. This filter housing design is
vulnerable, however, when it is used for applications involving light, easily airborne materials. Such materials,
if surface-deposited on the inside tube, can bypass the seals during a filter change because the seal can “roll
over” the material. Another potential drawback of this design is its orientation. It should be installed in a
vertical position for proper sealing. A horizontal installation will enable the seals to “take a set” and
eventually bypass the filter. This filter housing has been used at nuclear facilities in the United States for
many years with good reliability; however, its limitations should be noted.
Cartridge filters can be used for glovebox operations for both radioactive and nonradioactive applications.
These filters incorporate the filter housing and filter as a single unit and are supplied from the manufacturer
with options for pipe nipple connections on both the inlet and exhaust or on one end only. Test ports
should be specified when ordering, as these filters range in size and airflows. Prefilters should be installed
inside the glovebox for filters not already equipped with prefilters. A valve should be located on the outside
of the glovebox filter housing.
Radioactive Applications
In some radioactive applications, the cartridge filter should be located on the inside of the glovebox for safe
filter changing. The isolation valve is located on the outside of the glovebox filter housing.
Bag-in/bag-out side-access filter housings are used in some glovebox applications. They are available in sizes
from 35 cfm on up and in rectangular or round configurations, as discussed in Chapter 4. For radioactive
applications, it is desirable to mount the housing as close to the glovebox as practical. Long ducting or
Figure 7.5 – Push-through Filter Housing
HEPA
Filter
HEPA
Filter
Air
Flow
Air
Flow
HEPA
Filter
HEPA
Filter
Air
Flow
Air
Flow
HEPA
Filter
HEPA
Filter
HEPA
Filter
Air
Flow
HEPA
Filter
HEPA
Filter
HEPA
Filter
Remove Access Door
Place New Filter
Push New Filter
Remove
Safety Flange
Pull Out Old Filter
Secure Access Door
Clean Area
Inside Glovebox
Wall
DOE-HDBK-1169-2003 Chapter 7
7-9
plenum runs are not desirable due to their lack of access for cleaning. Mounting the filter housing directly to
the glovebox reduces the potentially contaminated surface area.
Redundant filter housings (Figure 7.6) are used
when working with materials that, if released
through the exhaust system, would be detrimental
with respect to both safety and associated cleanup
costs. All nuclear facilities use a secondary exhaust
before discharging to the outside air; this method is
a known as a “belt and suspenders” approach. In
some older facilities, manifold systems were not
designed for safe, clean decontamination. If
contamination migrates into these systems’ ducting,
cleanup is both costly and time-consuming. As a
result, use of a redundant filter should be
considered. The design of a redundant system
requires the use of an in-place-tested primary and
secondary HEPA exhaust filter installation.
Figure 7.6 shows two redundant filter housings—
one filter changed from inside the glovebox
(primary); the other (secondary) is shown as a bag-
in/bag-out type changed from the outside.
Section 9
7.2.2.2 Materials
It is important to understand the construction materials used on the filters and filter housings for gloveboxes,
particularly chemical processing gloveboxes. It should be clearly understood which chemicals and gases will
be introduced into the airstream of the glovebox and where they will be processed if processing is required.
If a bag-in/bag-out port is used, the bag material is subject to the same exposure to chemicals and gases as
the rest of the ventilation. If the process performed in the glovebox changes or other materials are
introduced into the glovebox system, the compatibility of the materials must be re-evaluated. Simply put, the
materials, ducting, blower unit, etc., must be compatible with the chemicals and gases exposed to the exhaust
airstream.
Filters are available in many different materials for different purposes. Wood, several different stainless steel
and aluminum materials, etc., are commonly selected for different applications. Recently developed
technologies such as stainless steel, ceramic, and Teflon® filter media have outstanding resistance to
chemicals, heat, and gases. However, these recent developments have not gained wide acceptance in nuclear
applications.
7.2.2.3 In-Place Test Ports
The size of a glovebox filter housing is relatively small compared to most filter housing installations. As with
any HEPA filter installation, test ports should be placed on the filter housing to validate the installation. The
criteria for testing gloveboxes focus on the proper location to inject the challenge aerosol, upstream, and
downstream samples. The test ports should be designed to be sealed after each use and to be as cleanable as
possible. This is usually a 3/8- to 1/2-inch half-coupling/nipple with the appropriate plug/cap. The weld
and finish of a test port should emphasize clean smooth surfaces, especially from the inner diameter of the
port to the filter housing. Cracks and crevices in this area are next to impossible to clean via access through
gloveports.
Figure 7.6 – Redundant Filter Housings
Exhaust Header
Glovebox
HEPA Filter Outside
Glovebox
HEPA Filter
Accessible
from Inside
Glovebox
Redundant Filter Exhaust
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-10
7.2.2.4 Bag-in/Bag-out Ports
Bagging ports are used on gloveboxes for multiple purposes such as transferring materials and equipment and
removing the waste generated during operations. Significantly, they are also used to transfer new or spent
filters while maintaining confinement. It is important to size the bagging port to accomplish this purpose,
and it is desirable to use a cylindrical bagging port because this design is much more “operator friendly.” A
typical bagging port should have two outer-raised ribs around the outer circumference to prevent the bag
from being easily pulled off during operations. The ribs are normally raised approximately 1/4- to 3/8-inches
above the outer circumference and 1 to 1.5 inch apart. A safety-restraining strap should be used to prevent
the bag from being easily pulled off. It should be installed whenever the bagging port is being used, and
should be removed only when performing the bag-in/bag-out (new bag installation) procedure. The strap is
secured between the two ribs. A cinching strap may be used to prevent the bag from being sucked into the
glovebox due to negative pressure. It is installed when the bagging port is not being used. An internal access
door may be used to isolate pressure surges and to act as a secondary confinement for the bag. The door
should have a seal to prevent egress of contamination from the glovebox. An external cover may also be
used to protect the bag and keep it out of the way of other operations. A “bagging kit” should be supplied
with a bagging port. It should contain the components, tools, and procedures to perform the operation.
These items are covered in Section 7.4.
Section 10
7.2.2.5 Sealing Mechanisms
There are multiple sealing methods for filter housings and filters used on gloveboxes. These can be
application-specific or site-specific and either gasket- or fluid-sealed. The designer should consider chemical,
gas, radioactivity, and heat as deciding factors in determining which sealing mechanism to employ. In some
applications, the filter housing is welded and incorporated into the glovebox. In others, the filter housing is a
bolted, gasketed installation. The bolted design is more versatile by design; however, a potential crack at the
gasket interface may make decontamination difficult. It should be noted that a push-through filter housing
should be bolted due to the housing manufacturing process. Filter seals vary by application. HEPA filters
can be supplied with many different gaskets and fluid sealing systems.
7.2.2.6 Blower Connections
If a dedicated blower is to be installed on a glovebox, several installation considerations should be addressed,
including vibration, exhaust connection configuration, and blower discharge configuration. It is generally
accepted practice to use a flexible connection in most ventilation applications; however, DOE-STD-10663
outlines the need for fire protection and the requirements associated with such installation. Vibration from
the blower will transmit to the filter housing and subsequently to the glovebox. If a flexible connection is
used to isolate vibration from the blower, there is a potential for heat damage to the connector.
Noncombustible materials should be selected for this application. Blower designs vary. Selection of the
exhaust and inlet connection should prevent severe effects on blower capacity. Obstructions at the
immediate inlet and outlet will grossly affect blower capacity. Elbows and tees at the inlet will also affect
capacity and should be avoided.
7.2.3 Dilution of Evolved Gases
A high air exchange rate is often required to dilute fumes generated in an air-ventilated glovebox. When
evolved gases, vapors, and particles are not flammable, toxic, or corrosive, flow rates sufficient to maintain a
negative pressure (with differentials from 0.3 to 0.5 in.wg in the box) may be employed. However, when
fumes or vapors are hazardous, a higher ventilation rate is necessary. The maximum generation rate of
hazardous substances must be determined to establish the minimum airflow rates needed for dilution. The
following equations can be used to determine minimum safe airflow rates.4
DOE-HDBK-1169-2003 Chapter 7
7-11
Q R S
L
= (10 )( )
6
, (7.1)
where:
Q = required dilution flow rate, cfm
R = contaminant generation rate, cfm
S = safety factor (4 to 10 is suggested, depending on volatility, flash-point temperature, degree of mixing, and
risk)
L = limit value of contaminant, volume parts per million (vpm) [use threshold limit value (TLV) for toxic
vapors and lower explosive limit (LEL), 4 converted to vpm, for combustible vapors].
If the contaminant vapor is evaporated from a liquid, the contaminant generation rate, R, can be determined
using the rate of liquid evaporated where:
R
W
M
(359)
t 460
492
=
+
(7.2)
W = liquid evaporation rate, pound of solvent per minute
M = molecular weight of contaminant
t = air temperature, degrees Fahrenheit
Section 11
Equation (7.2) above assumes that a pound mole of gas will occupy 359 ft3 at 32 degrees Fahrenheit and
standard pressure. The dilution flow rate, Q, in Equation (7.1) assumes that the dilution air is free of the
contaminant under consideration; otherwise, the background concentration of the contaminant in the dilution
air (in vpm) must be subtracted from the limit value, L, in the denominator.
Concentration gradients can easily be formed during rapid vaporization if the hazardous gas is much lighter
or heavier than air and there is poor mixing. Safety factors above 7 should be used in such cases. For
example, 1 pound of acetone evaporated in a box in 1 hour requires a dilution rate of 5.1 cfm multiplied by
the safety factor, S, to ensure dilution below the lower explosive limit.5 Since acetone evaporates rapidly and
has a flash point of 0 degrees Fahrenheit and an LEL of 2.2 percent, a safety factor of 10 should be used. In
operation, minimal amounts of a solvent like acetone should be permitted in the glovebox at any one time. It
should be assumed that the entire contents could be spilled, thus creating an event. Consideration should
also include feed-throughs where flammable liquids and gases are pumped or released into the glovebox
environment. The feed lines should be constructed of materials that are resistant to the gas or liquid. It is
preferable for these lines to be hard-piped to the glovebox, although this is not always practical. An isolation
valve should be provided to shut off the feed system in an emergency. It is preferable to use an automated
failsafe feature, with appropriate sensors, if the equipment located inside the glovebox is not explosion proof.
This is also preferable when the equipment is not monitored for long periods.
7.2.4 Heat Dissipation
It is important to understand the importance of heat removal as it applies to ergonomics. Operators access
the inside of the glovebox using gloves that are often awkward to use and gloveports that limit their
operations. When higher than normal heat conditions exist in a glovebox, it leads to higher fatigue levels.
This limits the operations that can be performed in the glovebox environment. For worker comfort,
sufficient air should be exchanged through the box to limit the inside temperature to no more than
15 degrees Fahrenheit above room temperature. When the calculated airflow rate for cooling exceeds the
exhaust cfm, consideration should be given to higher airflow (larger filters or more filters), supplementary
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-12
cooling, better insulation of heat sources, cooling coils, or chill blocks for hot materials. In the design phase
of a glovebox project, the designer should be aware of the heat load presented by the equipment that must be
located in the glovebox. It is desirable, when practical, to determine whether items like electric motors can be
placed to the outside of the glovebox. This can reduce the heat load inside the glovebox significantly, as well
as simplify maintenance and serviceability and reduce disposal costs. Operations to be performed in a
glovebox should be determined ahead of time. Airflow velocities can affect the operation of sensitive
equipment and cause materials like powders to become airborne. [Note: Negative pressure also can cause
equipment problems.] There are practical limits to the amount of cooling that can be accomplished by
airflow, since high airflow rates can create strong air currents if not properly diffused. Where possible,
operators should be protected from objectionable sources of radiant heat by surrounding the heat source with
reflective shields or conductive jackets. Exhaust airstreams may be routed through such shields to permit the
maximum pickup of convected heat before leaving the box.
Section 12
When the heat load to the glovebox has been determined, the required cooling airflow rate to dilute the hot
gases is calculated using the following equation.
Q
H
C(t t )
,
2 1
=
−
(7.3)
where:
Q = airflow, cfm
H = sensible heat change (by conversion), British thermal units (BTU)/hour (1W – 3.41 BTU/hour)
t1 = temperature of entering air, degrees Fahrenheit
t2 = desired average temperature inside box, degrees Fahrenheit
C = conversion factor for sensible heat change, BTU/(cfm x hr)(degrees Fahrenheit)
Both the density and specific heat of air at room conditions depend on the humidity ratio of the air. The
density also depends on the temperature. In a room at 75 degrees Fahrenheit and 50 percent relative
humidity (RH), the air density is 0.073 pounds per cubic foot (lb/ft3) and the specific heat is 0.24 BTU per
pound. Therefore, C is 1.1 BTU/ (cfm)(hr)(degrees Fahrenheit) and Equation (7.3) becomes:
Q
H
1.1 (t t )2 1
=
−
. (7.4)
Long-term operation of high-heat-producing equipment can damage filters when exhaust air temperatures
approach the temperature limit of the filters for continuous exposure to heat (see Chapter 3, Tables 3.5 and
3.6).
7.2.5 Empirical Flow Rates
It is important to design the ventilation system to provide a safe, ergonomically practical, and reliable unit.
Experience has shown that filter pressure drops will vary, ductwork loss will be greater, and blower
performance may be slightly different in actual working conditions (other variables also are discussed in this
chapter). If the glovebox ventilation system does not perform as designed, it should not be used or
commissioned until it meets the minimum safety requirements of this document and other referenced
documents.
DOE-HDBK-1169-2003 Chapter 7
7-13
Troubleshooting an installation should include the inspection of the ductwork and installation of the blower
(including wiring); the prefilter, inlet, exhaust HEPA filters; and the manifold (if equipped). Common
problems with new installations include debris lodging in the ducting, blower housing, and filter housing and
finding the blower motor wiring reversed. Long flexible connections will also affect performance since a
bend can dramatically choke off airflow.
7.2.6 Exhaust Requirements
Section 13
The maximum airflow rate from the glovebox determines the required capacity of the filters and the size of
the equipment for the entire downstream portion of the ventilation system. The airflow resistance of the
exhaust-air path must be sufficiently low so that pumping of gloves (pressure recovery) by operators in the
box will not result in positive pressurization. In small low-flow boxes such as those with inert atmosphere,
pressure surges due to glove pumping may be a serious problem. Fast insertion of the gloves can cause the
glovebox to reach a zero or positive pressure. Although this is typical for most applications, another method
called “passive recirculation” can be used to retain the inherent safety feature and larger filters for air cleaning
functions. [Note: This method should not be used with pyrophoric materials because the inert environment
will be lost during a glove breach.] Typically, the glovebox is fitted with an inlet and exhaust filter in a room
air application. Another filter “emergency discharge” is added and fitted between the blower discharge and
the inlet air filter. The blower installation connects the exhaust filter housing to the negative side of the
blower, and the inlet filter installation connects to the positive side. When the installation is complete, the
emergency discharge filter is in a standby condition. The ventilation unit basically recirculates the inert gas.
If a breach or leak occurs, the emergency discharge filter becomes naturally activated. The path of least
resistance during a breach discharges exhaust air through the emergency standby filter, since the inlet is now
the gloveport. This filter should also be sized for the gloveport “inherent safety feature.” The filter should
be rated for twice the cfm or half the pressure drop of the inlet filter. If the two filters, inlet and emergency
standby, have the same airflow and pressure drop, the airflow will be directed to both instead of the
emergency standby filter. If air is to be exhausted from the emergency standby filter, a bleed vent is necessary
to prevent removing the inert gas and imposing additional negative pressure. When the glovebox ventilation
unit is activated, there should be no flow through the emergency standby filter. If the secondary exhaust
system is directly connected without a bleed vent, the glovebox pressure will become extremely negative. The
vent allows room air to be removed until the emergency standby filter requires exhaust.
The maximum rate of exhaust flow from a room-air-ventilated glovebox is usually based on the required inlet
flow when a glove is ruptured or inadvertently removed. The air velocity into the open port should be
125 ± 25 fpm. Good contamination control is more easily achieved in a glovebox with low air leakage.
Gloveboxes should have a leakage of less than 0.02 to 0.5 percent box volume per hour, depending on the
application requirements. In some applications, such as inert environments, a helium leak test is performed
to ensure the integrity of the glovebox. The method, technique, and criteria for testing are given in
AGS-G001, Section 9.11.4.1
7.2.7 Vacuum- and Pressure-Surge Relief
Section 14
In some applications, gloveboxes must be protected against physical damage resulting from excessive
pressure or vacuum. The exhaust and inlet supply system must be able to handle slowly manifested pressure
or vacuum disturbances. Each glovebox containing service connections or internal equipment whose
malfunction might cause a pressure surge should be equipped for prompt surge relief. This also applies to
fire suppression systems, as outlined in DOE-STD-1066.3 The response time and pressure-flow
characteristics of the surge-relief device will depend on the flow and pressure characteristics of the pressure
source, the free volume, and the relative strength of the gloves and glovebox. The relative strength is defined
as the lowest pressure differential that will cause rupture of the glovebox pressure boundary at its weakest
point. Depending on the design of the box, the weakest point will usually be a window or a glove. The
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-14
surge-relief device can be a liquid-filled
U-tube, as shown in Figure 7.7. The
surge-relief flow capability should exceed
the flow from the largest possible source
of pressurization at the design relief
pressure. The HEPA-filtered surge-
relief line should not be connected to a
glovebox exhaust manifold because this
line will be subjected to the same
pressure as the normal glovebox exhaust
connection. A liquid storage reservoir is
provided to handle the blown seal fluid.
The filter and ductwork should be sized
in accordance with the required cfm and
pressure drop based on the pressure
surge. The filter should be protected
from impingement of the seal fluid. If
room air cannot be tolerated in the
glovebox, as is the case in some inert-
atmosphere applications, a different vacuum surge-relief system must be used. A U-tube can be devised to
restore its seal after relieving the surge, but such a system must include a feature to alert the operator that a
pressure surge has occurred so that he can make the necessary safety checks. An inlet filter may provide
surge relief if no backflow device or other restriction is provided. The filter face area would have to be about
four times the area of an unfiltered port to achieve an equal venting effect.3 [Note: Explosive venting is not
covered in this Handbook.]
7.2.8 Glovebox Exhaust Manifold
A glovebox exhaust manifold is used when multiple gloveboxes will share a common ventilation system. This
method reduces the amount of exhaust ventilation components for dedicated exhaust systems. The glovebox
exhaust manifold includes all of the glovebox exhaust system downstream from the point where the exhaust
from two or more gloveboxes joins and the airflow is combined. Sections 7.2, 7.3, and 7.4 discuss details of
the exhaust system and illustrate working examples.
The glovebox exhaust manifold draws air or exhaust gas from each connected glovebox at a controlled
pressure and airflow (interdependently), houses secondary treatment facilities, and transmits the air for further
treatment or exhausts it to the outside atmosphere. Primary exhaust treatment should be applied inside or as
close to the glovebox as possible and, in all cases, before connection of the exhaust line to the exhaust
manifold. It is critical to protect the manifold from contamination due to the difficulty of cleaning and
decontamination. In some systems, a portion or most of the cleaned or treated exhaust gas may be
recirculated back to the gloveboxes.
Section 15
[Note: The manifold system should be sized and controlled to accept a range of flow whose high extreme is
the sum of: (1) the maximum normal flow from each box (Sections 7.2.1, 7.2.2, and 7.2.3), (2) the largest
maximum flow under removed glove conditions from one of each of five connected boxes (Sections 7.2 and
7.2.6), and (3) an allowance for system growth. The low extreme is the sum of the minimum flows from each
box. An allowance for system growth should be provided at not less than 20 percent of (1) plus (2) above for
a new system. If this allowance exceeds 50 percent of (1) plus (2), other provisions such as installing an
equivalent dummy flow should be considered.]
Figure 7.7 – Glovebox Vacuum-Pressure Surge
Relief Device
Glovebox
Impingement
Protection
HEPA Filter
Blown Seal
Storage
Reservoir
Transparent
U-Tube
Seal Fluid
DOE-HDBK-1169-2003 Chapter 7
7-15
7.2.9 Exhaust Cleanup Requirements
Providing As Low as Reasonably Achievable (ALARA) exposure to radioactive material is the guiding
principle for determining the design of a glovebox ventilation unit. Protecting the exhaust downstream of the
primary HEPA filter is paramount for nuclear installations. Experience has shown that exhaust systems are
not only difficult to decontaminate, but have led to unnecessary operator exposures. It is also true that, after
filter breakthrough, nuclear particles can migrate to all the gloveboxes in the chain. As discussed earlier in
this chapter, a filter installation is only as good as the entire ventilation system.
When corrosive gases or vapors are in the exhaust airstream, all of the filters in a series will be exposed. The
impression that the life expectancy of a group of HEPA filters arranged in series is dependent upon the
number of filters in the series may be false when chemical or heat degradation occurs. Under these
conditions, when the first stage fails, there is a potential for others to fail from the same cause. Corrosive
gases and mists from vats, scrubbers, and similar equipment must be neutralized and removed before they
reach the HEPA filters.
Installation requiring redundant HEPA filters must have provisions for in-place testing. The requirements
are provided in ASME AG-1, Section TA2 and ASME N510, Testing of Nuclear Air Cleaning Systems; 5 and if
chemical detection systems are required due to possible filter installation damage, the monitoring system
should be HEPA-filtered to prevent damage to the instrument. Many manufacturers supply testable filters of
this type. These should be specified with upstream and downstream test ports. The filter flow should be
consistent with the monitoring instrument airflow.
7.3 Glovebox Filter Installations
For the most part, the glovebox filter systems discussed in this section are first-stage (primary) HEPA filters,
although redundant filters located upstream from the exhaust manifold (if equipped) connection are also
discussed.
Filters must be able to perform properly whether
they are clean or dirty. A maximum dirty-filter
resistance of three times the clean-filter resistance for
HEPA filters and two times the clean-filter resistance
for prefilters is generally used for design purposes.
Figure 7.8 gives the approximate airflow and
pressure-drop relationships for clean open-faced
HEPA filters. Figure 7.9 shows common locations
for HEPA filters near or inside gloveboxes. Type 2C
shows the installation of inlet and exhaust filters
inside the glovebox.
7.3.1 HEPA FILTERS
Section 16
A detailed discussion of filter performance and
construction materials is given in Chapter 3,
Section 3.3. Operational experience with a particular
system is the most reliable basis for filter selection
for a particular service. For new and untried systems, the initial choice should be limited to the traditional
site-specific, open-faced pleat, and should be constructed to the requirements of Section 3.2. These filters
should also meet the requirements of ASME AG-1.2 If exhaust streams are kept chemically neutral, as they
0
0 25 50 75 100 125 150
0.5
1.0
1.5
3.0
2.5
2.0
Flow Capacity (cfm)
P
re
s
s
u
re
D
ro
p
(i
n
.w
g
.)
8 x 8 x 5
in
.
7 8/
8
x
8
x
3
in
.
1 16/
12 x 12 x 5
in.7
8/
Figure 7.8 – Flow vs. Pressure Drop
Relationship for Small, Clean, Open-face
HEPA Filters
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-16
should be for reliable exhaust system
operation, HEPA filters of standard
construction usually provide the most
economical service.
A single-HEPA-filtered exhaust path is
defined as a glovebox that does not involve
highly toxic aerosols or potent, toxic, or
radioactive materials, i.e., materials that do not
pose a hazard to the operator during a filter
change-out. A multiple-filtered exhaust path
is defined as a glovebox requiring more than
one line of defense from particle penetration.
This occurs when the exhaust ductwork or
manifold must be protected or the Most
Penetrating Particle Size (MPPS) is well below
the efficiency particle mean of the filters.
When continuous airflow is essential, two
exhaust connections should be provided to
avoid interruption of exhaust flow during a
filter change and to provide standby protection in the event of system upset. The purpose of multiple
exhaust connections is to allow an emergency connection to be made. Figure 7.10 illustrates single- and
multiple-filtered exhaust connections for a glovebox.
Multiple-filtered exhaust connections should be used when interconnected gloveboxes or a large enclosure
with several compartmented work areas are needed. Compartmenting doors between work areas or between
single boxes in an interconnected line must not isolate a work area with only one filtered exhaust connection.
The multiple exhaust points required to handle total airflow in a line of interconnected boxes must be sized
for maximum flow and valved individually for flow control. DOE-STD-10663 discourages the use of long
lines of interconnected gloveboxes for fire control. Where they are necessary, fire doors between the
gloveboxes should be provided. This would necessitate proper alarming and resolution of pinch-point
concerns.
The glovebox designer should understand the limitations imposed by ergonomics. There is an art to
designing the glovebox, ventilation service, and internal equipment operation and service. Some facilities
build mockups of the glovebox concept to determine whether the operations can be done in a practical
manner. It is critical to prove the practicality in some operator-intensive, hands-on operations and long-term
production activities. Tasks performed within the confines of a glovebox should factor in the weight of the
objects handled and the location of the operation(s) to be performed within. It is better to demonstrate the
activities at the design phase than to wait for the glovebox to be built. Failure to do this can be very costly to
repair and can seriously compromise operator safety.
Section 17
The fatigue factor is high when working in a glovebox. The working pressure, heat, glove sleeves, gloveport
location, and operations where the arms are outstretched all add to fatigue. Intricate or sensitive work
significantly adds to fatigue because the operator cannot feel through the gloves. If visibility is poor or
nonexistent, operations will be very difficult, if not impossible, to perform. Some operations with older
gloveboxes used mirrors to perform some operations. [Note: This was done out of necessity due to poor
design or a compromise with some other activity.] In glovebox terms, “extended reach” is used to describe
an occasional operation where something is pulled forward to a working position or a simple operation such
as turning a switch off or on (e.g., lowering or pulling out a spent filter for disposal). Extended reach should
be avoided in repetitive or routine operations.
Figure 7.9 – Possible Arrangements of Filters
Near or Inside Gloveboxes
Note: Type 1C is not suited for containment of radioactive materials
within the glovebox but is applicable where the intent is to exclude
air borne particles from the glovebox space.
Filter
Type 1
Type 2
AA B C
Glovebox See Note
DOE-HDBK-1169-2003 Chapter 7
7-17
7.3.2 HEPA Filter Selection Criteria
HEPA filters are available in many configurations for many applications. For most applications, glovebox
HEPA filters are customized to meet industry needs. Not all the different filter housings described earlier are
intended for nuclear service. These filter housings use different-sized filters with different types of seals.
Filter selection should be based on airflow requirements and efficiency requirements. Airflows for protecting
workers, venting fumes, and cooling are discussed in this section. The efficiency of HEPA filters is discussed
in Chapter 3.
Another variable to application is efficiency. Selecting a more efficient filter for an application may be
necessary to prevent particle bypass through a standard HEPA filter. The higher-efficiency filters are called
Very Large-Scale Integrated (VLSI) filters. There are materials in use that have a greater amount of small
particles below the MPPS for HEPA filters. These materials may pass through the HEPA filer unimpeded
and migrate into the ductwork. Redundant filters can sometimes be used for these applications; however, this
assumes that the area between the filters can be cleaned. [Note: VLSI filters are not approved for nuclear use
and are referenced for nonnuclear applications).
Figure 7.10 – Suggested Arrangements for Single- and Parallel-Filtered Exhaust
Connections for Gloveboxes
Exhaust Header Exhaust Header
Glovebox
Airflow and Static
Pressure Adjusting
Damper and Cutoff
Device
HEPA Filter
Accessible
from Inside
Glovebox
(a) (b)
Single Exhaust
Connection
Multiple Exhaust
Connections in
Parallel
Single Stage of Filtration
Exhaust Header
Exhaust
Header
Exhaust Header
Glovebox
HEPA Filter Outside
Glovebox
HEPA Filter
Accessible
from Inside
Glovebox
(c) (d) (e)
Single Exhaust Connections
Filter Stages in Series
Multiple Exhaust Connections
to Box in Parallel Second Stage
Filter Common to Both Connections
Parallel Exhaust Connections
to Box in Parallel Second-Stage
Filters for Each Box Connection
Two-Stage of Filtration
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-18
Several of the characteristics listed below should be considered when selecting filters for use at nuclear sites.
Section 18
• Uses a standard-size HEPA filter located in the back- or end-wall of the glovebox.
• Maximizes inside box space by partially recessing the filter in the wall.
• Provides adequate space to transfer the HEPA filter out of the glovebox (see Table 7.1).
• Has a simple clamping method with no removable pieces and is operable with a gloved hand by a simple,
clean clamping mechanism.
• Has a retainer that serves as a face shield for the filter and permits attachment of a steel-cased prefilter by
a flexible magnetic strip (accessible from the front); the filter remains in position after being unclamped
because of the folded lip at the top.
Table 7.1 – Glovebox Bag-Out Port Sizes for Transfer of Standard Open-faced HEPA Filters
Required Port Size (inches)
Filter Size Round (diameter) Rectangular
8 × 8 × 2 1/16 9 3/4 8 ½ × 4 1/2
8 × 8 × 5 7/8 10 3/4 8 ½ × 6 1/2
12 × 12 × 5 7/8 14 12 ½ × 6 1/2
24 × 24 × 5 7/8 26 25 × 6 1/2
24 × 24 × 11 1/12 27 3/4 25 × 12
7.3.3 Prefilter Selection
Prefilters are used to extend the life of the more expensive HEPA filters located at the inlet and exhaust filter
housings. These filters are disposable and should be routinely changed when they are loaded and affect the
ventilation system. This can be determined by noting the sensitivity of glove movement and pressure
recovery. In easily airborne powder applications where a significant amount of dust is airborne in a glovebox,
removing the prefilter may be the only means to restore safety (negative pressure) to the glovebox during a
powder mishap. Prefilters for gloveboxes come in a range of sizes and configurations. Some facilities use
simple cut, in-place pads, and some use HEPA filters (not tested) to perform the prefilter function. This has
been application-, site-specific-, and retrofit-driven. For some applications where air entering the glovebox is
HEPA-filtered and there is little or no dust loading in the glovebox, an exhaust prefilter may not be needed.
A prefilter should be considered on the inlet HEPA filter on the glovebox unless the glovebox resides in a
cleanroom. Prefilters are manufactured from a fiberglass media similar to the HEPA filters. As a result, they
are susceptible to the same chemicals, fumes, and heat damage. Some prefilters are manufactured with a
beverage board (coated cardboard) frame, which should be avoided if fire is a concern.
Prefilters are typical of the type referenced in Chapter 3, Section 3.4, as Class I panel filters. The main
advantage of these prefilters is cost, quick installation, and removal. There also is a distinctive ergonomic
advantage. These filters are pushed into a channeled frame instead of tucked into and around a frame—a
difficult operation when the exhaust filter is ceiling-mounted. Use of a separate removable frame is
preferable in these applications. [Note: The ability to perform this operation should be based on either a
mockup or an existing glovebox installation.]
Prefilter holding devices should be manufactured from the same material as the glovebox or a material that is
resistant to the chemicals and fumes that will be present in the airstream. Retaining fasteners, when used,
DOE-HDBK-1169-2003 Chapter 7
7-19
should be made of dissimilar materials that do not gall. It is better to dispose of a 302 stainless steel wing nut
than to replace a 304-L stainless steel stud welded on a glovebox. The frame should be designed to minimize
air bypass around the prefilter, yet allow enough clearance between the HEPA filter and prefilter to prevent
media contact. An independent holding frame should be incorporated in the design to prevent disturbing
another filter installation.
Section 19
7.3.4 Inlet HEPA Filters
Work performed in gloveboxes frequently requires supply air that is free of airborne contaminants. Inlet
HEPA filters help maintain clean conditions inside and, when chosen properly, also serve three other useful
functions: (1) extending the service life of the exhaust filter by protecting them from atmospheric dirt loading,
(2) preventing the spread of contamination from
the glovebox to the room in the event of a
glovebox pressure reversal, and (3) providing
overpressure relief.
The design of the inlet filter installation is relatively
simple for air-ventilated nonrecirculating
gloveboxes. Since no duct connections are
required, open-faced filters may be used with an
installation and clamping method that leaves one
face completely exposed. Typical methods of
installation are shown in Figures 7.11 and 7.12.
Because they are less likely to be contaminated,
inlet air filters are easier to replace than exhaust
filters; therefore, they provide fewer problems and
less risk during changes. Whether mounted to the
glovebox internally or externally (external
mounting is preferred), the same high-quality
mounting, clamping, and sealing are required.
The open face of the filter must be protected from
physical damage and fire. Plugging of the inlet
filter by smoke is a secondary concern, however,
since one recommendation for glovebox fire
suppression is to reduce normal airflow. Locating
the inlet connection (or an attached inlet duct) high
in the box tends to reduce the amount of air drawn
into the box during a fire because of the chimney
effect.
7.3.5 HEPA Filter Selection
The number of types and sizes of HEPA filters
used at an installation should be minimized for
logistical and operating economy. All HEPA filters
should be constructed of fire-resistant materials.
HEPA filter sizes used in glovebox systems vary,
with square 8- × 8- × 3 1/16-inch; 8- × 8- × 5
7/8-inch; and 12- × 12- × 5 7/8-inch sizes and
nominal airflow capacities of 25, 50, and 125 cfm,
Figure 7.11 – Open-Face Filter
Installation Method (a)
Exhaust Duct
Connection
8 x 8 x 5 7/8 inch
Open Faced HEPA Filter
Four Wing Nuts
to Compress
Filter Gasket
HEPA Filter
Retainer with Perforated
Face (1/4 inch Holes Staggered
3/8 inch Centers, 40% Open)
Back Wall of Glovebox
Acts as Gasket
Sealing Face
Sealing
Gasket
Airflow
Figure 7.12 – Open-Face Filter
Installation Method (b)
Exhaust Duct
Connection
8 x 8 x 5 7/8 inch
Open Faced HEPA Filter
Prefilter Pad when
Coarse Airborne
Particles will be
Encountered. Pad
must be Replaceable
without Disturbing
Sealing of HEPA
Filter
HEPA Filter Retainers
Airflow
Drip Shield to Protect
Filter Face Attached to
Retainer (Removable for
Access to Prefilter)
Back Wall of Glovebox
Acts as Gasket
Sealing Face
Sealing
Gasket
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-20
respectively. Glovebox filters should be operated at their design airflow. Wood-cased fire-resistant HEPA
filters are less expensive and should be considered wherever the operating environment (temperature,
humidity, etc.) permits. Most applications use 304 and 304-L stainless steel due to the robust nature of the
casing and the chemical, fire, and humidity requirements. The “cartridge,” as noted in Figure 7.5, comes in a
round configuration with an 8-inch diameter.
Disadvantages of Enclosed and Open-Faced HEPA Filters. Disadvantages of both enclosed and open-
faced HEPA filters include:
Section 20
• Capacities are insufficient for large amounts of dust.
• Chemical fumes such as caustic or hydrofluoric acid mist can destroy filter medium separators and
adhesives.
• Sharp corners and edges of metal casings can damage protective bagging.
• In dry atmospheres (less than 2 percent RH) the plywood of wood-cased HEPA filters may shrink and
delaminate, eventually causing failure of the filter. Extremely low moisture levels may cause a shrinkage
problem for particleboard casings as well. This could be an acute problem in inert atmospheres where
very low moisture levels [less than 50 parts per million (ppm)] have to be maintained. In such systems,
steel-cased filters should be used.
Open-faced HEPA filters have the following additional deficits:
• They are vulnerable to damage during handling and storage.
• They lack a handle or gripping area for easy withdrawal from an enclosure.
• It is difficult to replace damaged face gaskets.
Enclosed HEPA filters also have additional deficits:
[Note: They are not recommended for nuclear applications stated in Chapter 3.]
• They lack Underwriters Laboratories (UL) certification.
• Reeding (induced vibration of separators caused by air motion) at high flow rates is worse than in open-
faced filters because the entering air impinges on a smaller area of the filter pack.
• Their weight is greater than that of open-faced filters.
• They cost substantially more than open-faced filters.
• They have greater space requirements.
• There is an air leakage problem with steel cases, especially in inert-atmosphere and high-pressure
applications.
• There are no visible means of detecting damage to the medium.
DOE-HDBK-1169-2003 Chapter 7
7-21
7.3.6 Prefilters
As in larger systems, prefilters may be used in both the inlet and exhaust airstreams to extend the life of the
HEPA filters used in glovebox filtration systems. Prefilters are inexpensive items, and the decision to use
them requires the designer to evaluate the advantage of longer HEPA filter life against frequent glovebox
system problems associated with limited space. Prefilters attached directly to the face of the HEPA filter
provide no fire protection for that HEPA filter. Glovebox prefilter service often requires filters to be
subjected to periods of high temperature, moisture, dust, and corrosive agents that shorten their effective life
and mounting.
Experience with prefilters in glovebox ventilation systems has shown that the use of metal media is
impractical. Without viscous coatings, the filtering efficiency of metal-media prefilters is poor, and these
filters are often almost impossible to clean and decontaminate. Adhesives and oil coatings that improve
particle retention reduce in-box cleanness and fire resistance. Experience clearly indicates that using
conventional types of prefilters that require cleaning or decontamination or both before reuse also is
impractical. Throwaway filters with simple installation methods are preferred. After use, the units are
discarded as contaminated waste unless collected materials must be reclaimed. Glass-fiber-media prefilters
are preferred because they offer good serviceability, low costs, and only a small amount of combustible
content.
Inlet airstreams with HEPA filters should be fitted with prefilters when using atmospheric air. However,
there may be no need for a prefilter when: (1) the room air has been cleaned of the bulk of its airborne dust
by building supply-air systems, (2) local room activities do not generate dust and lint that can be drawn into
the box, and (3) airflow through the HEPA filter is less than 75 percent of its rated capacity.
Section 21
A common method of prefiltering in older gloveboxes is to clip a thin (1/8- to 1/4-inch) fiberglass pad to
both the inlet and exhaust HEPA filters, as shown in Figure 7.13. Neither plastic foam nor organic fiber
should be used because both are flammable. The pad is cut to fit the face of the HEPA filter and is clipped
to the filter retainer. This method of attachment permits easy removal of the prefilter pad without disturbing
the seal of the HEPA filter. Normal usage generally requires frequent replacement of the prefilter pads,
which do not have much dirt-holding capacity and can quickly become plugged by house dust and lint.
Convenient methods of attaching the prefilter pads are essential to simplify the operations performed inside
the glovebox. Frequent replacement of prefilter pads provides the following benefits:
• Air resistance (pressure drop) does not change rapidly, which allows airflow to remain more constant
without frequent manipulation of airflow dampers.
• Accumulation of combustible dust in the exhaust path is lessened, thereby providing better fire
protection for the HEPA filter downstream if the prefilter is not applied directly to the face of the HEPA
filter.
• The exhaust path can pass a greater airflow when relieving an emergency condition.
Thin fiberglass pads (1/4-inch thick or less) can provide average atmospheric dust collection efficiency of up
to 20 percent with low airflow resistance. Thin, clean fiberglass pads used at air velocities of 35 fpm will
create an initial pressure drop in the range of 0.03 to 0.15 in.wg. For applications where long-term
continuous processes hamper regular maintenance of in-box filters, the designer must include the following
provisions:
• Greater suction pressure (well below the limit that would subject glove or box integrity to unsafe
differential levels) controlled by the damper to allow longer use of prefilters;
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-22
• Larger prefilters; and
• Selection of a prefilter with less initial resistance to permit longer use, even with lowered collection
efficiency.
7.3.7 Roughing Filters
In some installations, it is desirable to recover material from the filters for either reprocessing or waste
minimization. Roughing filters may be used for this purpose. The filter medium is typically less efficient than
that of the HEPA filter. Construction materials may be suitable for the recovery process (Category 3 -
combustion, acid dissolution, etc.), but must not present a hazard to the downstream prefilter and HEPA
filters. Fire screens, etc., must be used to prevent roughing filters from impacting downstream prefilters or
HEPA filters.
7.4 Filter Replacement
Safe replacement of a contaminated glovebox filter must be planned in the design phase to facilitate proper
execution. The filter change method and other maintenance functions, if not site-specific, should be
determined and planned. The designer should prepare a written preliminary filter change procedure along
with the design documents. If the design is questionable due to an extreme custom nature, the glovebox
should be mocked up so that an operational demonstration can be performed. [Note: In the past, special
tools were used to perform filter and maintenance operations out of necessity and should be avoided, if
possible.] In applications where controlled inert atmospheres are present, filter changes should be planned
for times when other routine or special maintenance operations are taking place inside the box to reduce
Section 22
Figure 7.13 – Typical Installation of Prefilter Pads on Face of HEPA Filters
Prefilter Pad Clipped to
Face of Filter Retainer
HEPA Filter
Glovebox
or Enclosure
Prefilter Pad Clipped to Face of
Filter Retainer and Drip Shield
HEPA Filter
Glovebox
or Enclosure
Inlet Air Filter Installation In-Box Exhaust Filter Installation
DOE-HDBK-1169-2003 Chapter 7
7-23
interruptions to operations and loss of inert gas, and to minimize the time required to reintroduce the inert
gas into the box spaces.
The operational team directly involved in a filter change-out must wear appropriate respiratory protection, as
specified by site-specific requirements. Filters installed inside the glovebox must be accessible via the gloves
on the glovebox. When total contaminant activity is high, additional protective measures may be necessary to
reduce worker exposure. One of the safest and most common methods for preventing the spread of
contamination while maintaining confinement is bagging the filters in and out of the glovebox. The plastic
bagging materials used are discussed in Chapter 6, Section 6.2.3. When inert-atmosphere or oxygen-free
environments are used inside the glovebox, additional provisions may be required to prevent air leakage into
the box.
Replacement of a HEPA filter inside an air-ventilated box involves many steps that must be performed
sequentially. Standard Operating Procedures must be written, and the filter change team must be trained to
perform the operations in a safe, controlled manner. Close coordination between maintenance and operating
personnel is necessary to establish a mutually satisfactory date and time for the filter change, to identify the
boxes and systems involved, to procure the necessary materials, and to schedule personnel. The health and
safety requirements of the industrial hygienist, health physicist, and safety engineer must be established. One
of these specialists should be designated the health and safety supervisor and should be available to monitor
the operation and assist as necessary.
When the necessary materials and tools are ready and all personnel have been instructed in their specific
duties, final permission must be secured from the responsible operator to alter the airflow and replace the
filters. The flow path of the exhaust system should be thoroughly understood, and persons responsible for
related exhaust systems that will be affected should be forewarned. For instance, if two glovebox exhaust
systems manifold to the same blower, final filters, and stack, the removal of one system from service for a
filter change will affect the system flow and pressure characteristics of the other system. Safety clothing and
respiratory protection should be worn as directed by the health and safety supervisor. The following steps are
suggested for changing a filter and placing a box back in service:
1. Cease all glovebox operations and contain unsafe materials in suitable containers.
2. Cut off gas flow to the glovebox affected, and adjust flow through the remaining branches to restore a
safe negative pressure and flow rate in each.
3. Bag a clean replacement filter (and prefilter if used) in a small, clear plastic bag with sufficient tape to
hold the spent filter and prefilter with all of the hand tools required, as shown in steps A, B, and C of
Figure 7.14. It is recommended that the hand tools needed for filter changing be introduced the first
time the filters are changed, and then left in the glovebox for subsequent use if space and environment
permit. Decontamination is often more costly than tool replacement.
Section 23
4. Using the glovebox gloves, remove the dirty filter and prefilter from their mounting frame.
5. Insert the dirty filter and prefilter into an empty plastic bag along with any residual materials, slowly expel
excess air, and seal with tape.
6. Inspect the gasket sealing face or fluid seal knife-edge of the mounting frame and clean if necessary.
Place the replacement filter in position and secure the clamping devices. Place the new prefilter in
position and secure.
7. Remove the dirty filters and all debris from the glovebox and place the removed items in a container for
contaminated waste disposal.
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-24
8. Restore airflow through the glovebox and adjust the flow and negative pressure throughout the system.
9. Before glovebox operations are resumed, test the newly installed HEPA filter with challenge agent, using
the permanent test connections on the housing. If the test result is not satisfactory, stop the flow and
inspect the filter for damage. If no damage is apparent, reposition the filter, restore the flow, and retest
the filter. If the second filter challenge is unsatisfactory, the filter should be replaced and steps
3 through 9 should be repeated. Continued leakage suggests a mounting frame failure, filter damage, or a
faulty test, and each possibility should be examined in detail until the fault is discovered and corrected.
10. Decontaminate the area.
11. After successful filter replacement, notify the responsible operator.
Filters located external to a glovebox (used in some older glovebox installations) require convenient access
for changing, and it is usually necessary to interrupt airflow during the change. Since they are located outside
the glovebox, highly contaminated filters must be bagged during the change. Different bagging techniques
provide different degrees of protection. The technique shown in Figure 7.15 is an old method of filter
change, and is not recommended in new installations. This method seals both ends of the air ducts, and no
flow can occur downstream while the filter is removed. When uninterrupted airflow through a box is
required, this method of filter change necessitates the use of multiple exhaust connections on the box. An
out-of-box filter in the process of being removed from a system by the procedure, illustrated in Figure 7.15
Step 3, is shown in Figure 7.16. [Note: This type of installation should not be used on future nuclear
installations due to the potential for contamination release and cleanup. Further, note that flexible hose
connections as shown in Figure 7.15 should never be used for new nuclear applications.]
Figure 7.14 – Filter Changing Process
Access Port with Bag Stub
Attached and Cover in
Place
Enclosure
Inside
Contaminated Outside Clean
Hand Tool(s)
New Filter
Prepared for
Inside Use
(A)
(W)
Cover Removed and Laid
Aside, New Plastic Bag
Attached to Port Over
Existing Stub with New
Filter and Hand Tool(s)
Inside
Old Bag Stub
Old Bag Stub Removed,
New Filter Placed Inside
Enclosure
For Immediate Exchange of
New Filter with Spent Filter,
Omit Step W and Begin at
Step X Using this Bag
(B) (C)
Access Port
with Bag Stub
(Cover Removed)
Outside Clean
(X)
New Plastic Bag
Attached to Port
Over Stub, Stub
Is then Removed
Spent Filter
Old Bag Stub
Note: Hand Tools
May Be Stored in
the Box for Future
Use.
(Y)
Plastic Bag Is Deflated, Heat
Sealed, and Cut in the Seal
Area, Leaving Sealed Ends
Section 24
Stub on Enclosure and
Sealed Bag Containing
Spent Filter and Old Bag
Stub on Outside of
Ready for
Disposal
Enclosure
(Z)
Cover Secured
New Filter Bagged Into Contaminated Enclosure
Spent Filter Bagged Out of Contaminated Enclosure
DOE-HDBK-1169-2003 Chapter 7
7-25
Exhaust Connection Disjointed, Bag Sleeve
Extended and Heat Sealed, Sleeve Cut in
Sealed Portion to Preserve Seal of Both
Ends. Sealed Sleeve Stub Remains on End
of Exhaust Duct.
Inlet End of Filter is Disjointed, Heat
Sealed and Cut from System Similar to
Step 2, Preserving Seal on Glovebox
Connection. Insert Dirty Filter in
Additional Plastic Bag and Seal End
for Disposal as Contaminated Waste.
Exhaust Connection
Flexible Hose
Metal Duct
Adjustable Clamp for
Securing Assembly
Enclosed
HEPA Filter
Plastic Bagging Sleeves
Secured and Sealed at
Filter End by Sealing
Gland: at Metal Exhaust
Duct End by Elastic
Fastener on Grooved Ring.
Glovebox
Normal Position Exhaust Connection Severed
Dirty Filter Separated from System
Clean Filter Inlet Sealed Over
Sleeve Stub on Glovebox
Exhaust Connection Sealed to
Filter, Air Flow Resumed
Normal Position Restored with
Clean Filter in Place
Clean Filter Inlet Sealed Over
Sleeve Stub on Glovebox
1 2
3
4
6 7
5
Closed End
Pocket in
Sleeve
Open
End
Open
End
Clean Enclosed HEPA Filter Prepared in
Advance with Plastic Bagging Sleeves and
Sealing Glands on Filter Casing Nipples.
New Sleeve on Inlet Side of Filter is
Attached to Grooved Ring Over Old
Sleeve Stub with Elastic Fastener,
Deflate Sleeve.
Old Sleeve Stub Removed from Glovebox
Connection by Reversing Closed End
Pocket in Sleeve and Using as Glove.
Recover Pocket with Stub in End of
Pocket. Engage Filter Sealing Gland
Into Box Connection. Stub is Heat Sealed
in Sleeve End, Cut Away (Preserving Seals)
and Discard as Contaminated Waste.
Exhaust Duct is Joined to Outlet End of Clear
Filter Similar to Step 5. Particular Caution
Necessary to Prevent Loose Stub from Being
Sucked Up Duct. Allow Bagging to Deflate Before
Connecting Duct. Secure Assembly with Adjustable
Clamp.
Fold Sleeves and
Protect from Rupture
Where Traffic Requires.
Figure 7.15 – An Older Method of Filter Change [Note: Not recommended for new
installations, a bag-in/bag-out filter housing is recommended for new installations.]
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-26
For other methods where bagging does not
block the airflow path (e.g., using the
housings represented by Figure 7.15), but
merely encapsulates the filter being
removed or replaced, there is a dependence
on the damper in the duct to prevent blow-
by (leakage) during a filter change. In other
methods, isolation dampers or valves are
used to isolate the filter during a filter
change. The filter housing is still adjusted
to the glovebox to remain slightly negative
in pressure. The technique of bagging
filters from housings (Figure 7.15) offers
protection only for local personnel and the
service area where the filter mounting
device is located. The side of the system
downstream of the filter is protected not by
bagging, but by leak-proof dampers and
flawless handling of the dirty filter. Because
any dislodged particles will be swept
downstream when airflow is restored,
downstream HEPA filters should be
provided to intercept these particles.
7.5 Glovebox Safety
Section 25
The history of glovebox safety in the United States began with the use of very unsophisticated gloveboxes of
simple design for simple operations. These were “sandblasting-style” gloveboxes with and without filters.
Some early gloveboxes were actually manufactured from plywood. Glovebox use evolved from the need for
safe working environments and reduced operator exposure. This evolution led to more complex gloveboxes
and more complex problems. Most lessons learned were the result of accidental experiences. Simply put,
many variables existed due to lack of experience with glovebox use. Through all of these experiences, much
was learned about ergonomics, operator safety, the importance of training, and fire and explosion protection.
Ergonomic problems related to handling material, performing service functions, and transfers were
discovered early and are still a critical requirement in glovebox design. Operator safety has improved as a
result of better glovebox designs with less operator intervention. Training has become a critical path from
design through commissioning, operation, and decommissioning. Fire prevention is important enough that a
chapter in DOE -STD-1066, Fire Protection Design Criteria,3 was written specifically for gloveboxes.
7.5.1 Protection Against Fire and Explosion
The current guidance regarding fire and explosion is given in DOE-STD-10663 and DOE O 420.1, Facility
Safety 6 which outlines the requirements for glovebox applications needing fire suppression (see Chapter 10 for
more discussion of fire protection).
Fire Protection. Applications employing fire protection are guided by the following principles:
• Use nonflammable materials as much as possible in construction. Gloves and windows are the most
susceptible to fire due to their construction materials. Laminated or tempered safety glass is the material
of choice regarding fire. [Note: For applications where explosion, overpressure, or moving or rotating
machinery are a concern, impact-resistant, fire-retardant polycarbonate should be used to protect the
Exhaust Duct with Plastic Sleeve Stub in Place
Rear Side of Glove Box
Box Connection Sealed with Plastic Sleeve Stub
Dirty Filter with Sealed End Nipples Secured in Plastic Bag
and Ready for Disposal as Contaminated Waste
Figure 7.16 – Removal of an Out-of-box Filter
DOE-HDBK-1169-2003 Chapter 7
7-27
worker.] Some material hazards may also dictate the use of high-impact material due to the hazards to
operating and maintenance personnel from a cracked or broken window. Some applications resolve this
problem by placing a layer of glass inside the glovebox.
• Strictly adhere to acceptable housekeeping practices. Spontaneous combustion of certain materials can
occur in a glovebox as well as in the secondary work area.
• Avoid the use of flammable materials within the box wherever possible and limit the amount of
flammable material to the calculated air change (see Section 7.2) when no suitable nonhazardous
substance can be substituted. Use containers for flammable substances that are approved for the planned
operation.
• Maintain a current in-box material inventory. Gloveboxes should be used as designed. They are
inappropriate for long-term storage, especially for chemicals.
• For inoperative gloveboxes, establish a safer, glovebox configuration and periodically check to ensure the
gloveboxes are in a safe condition. Precautions include isolating boxes by closing fire stops, checking
through-flow, checking port covers, disconnecting electrical equipment, and removing corrosives.
Section 26
• Design the box with downdraft ventilation (high air inlet, low outlet) if possible to inhibit combustion
while still purging the box. Generation of light flammable gases by the process may dictate exhausting
from the top.
• Provide a protective atmosphere (see Section 7.5.2). This measure is listed last because those preceding it
are applicable to all gloveboxes, whereas inerting is used only when there is too much risk involved in
operating without a protective atmosphere. Assessing the degree of risk involved in an operation is often
a subjective evaluation.
7.5.1.1 Detection
A glovebox fire detection system is recommended when there is a high risk of fire determined by a Fire
Hazard Analysis (FHA). If flammable solvents, coolants, packaging materials, etc., must be present during
operation, especially in unattended boxes, a heat detector should be installed on the glovebox. Fire detectors
should be consistent with DOE-STD-1066.3 Fire detectors are required in plutonium gloveboxes due to the
pyrophoric nature of the material.
7.5.1.2 Suppression
Since a fire within a glovebox may be of paper, chemical, electrical, or pyrophoric metal origin, there is no
single suppression method that is best for all gloveboxes. This is discussed thoroughly in detail in DOE-
STD-1066.3 However, when designing a glovebox, the designer should be aware of the materials, material
quantities, process, and interfacing equipment that will be involved in the installation. At this point, the FHA
should determine the proper suppression system for the installation. The fire suppression system must not
cause a breach of the glovebox confinement that can spread contamination and increase the personnel
exposure hazard to an unacceptable level.
There is no assurance that filters will remain functional during and following exposure to fire, smoke, or
burning debris. Variable destructive effects on prefilters and HEPA filters include the temperature reached
during a fire, the quantity and density of the smoke released, and the duration of the fire.
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-28
7.5.2 Inert Environments
Inerting a glovebox environment is done when working with materials that are pyrophoric, oxygen-sensitive,
or moisture-sensitive, or when a process must be protected. Inert gases such as helium, argon, and nitrogen
are metered into a gas-tight glovebox to displace the “air” volume. The characteristics of the gas (lighter than
air, heavier than air) are applied using proper sampling sensors to obtain a true inerted glovebox. In
pyrophoric and high-fire-potential applications, oxygen sensors are used to verify real-time concentrations.
Inline filters should be installed to protect the oxygen monitor, or any monitor, from contamination.
Monitors and sensors are available for many different types of gases and fumes. These should be selected
when fire, explosion, and any associated risk to the process would result in danger to personnel and/or the
facility. This should be determined by the facility risk and fire assessment groups. In most of these instances,
the facility fire department should be directly connected to any alarms related to the event.
Gas-tight systems require quality construction of all components including gloveboxes, filters, and associated
ducts. Any air ingress associated with the filter mounting or connecting duct will adversely affect the quality
of the inert atmosphere that can be maintained in the glovebox and thus the cost of inert gas purification.
Penetrations used to pass electrical input/output signals and power into the glovebox should be hermetically
sealed for this purpose.
Section 27
In fire protection applications, the preventive step of inerting is safer, though more expensive, than
extinguishing a fire if it does occur. However, oxygen must be reduced below 1 percent before it fails to
support the burning of some pyrophoric metal.1 The use of dry air (RH less than 20 percent) reduces the
hazard of pyrophoric metal fires, but does not eliminate it. Moisture in the presence of heated pyrophoric or
reactive metals (e.g., finely divided plutonium) increases the possibility of explosion by generating hydrogen.
The suitability and cost of an inert gas for the process are significant factors when selecting this type of fire
control. The gas flow rate in most inert gas boxes is generally low. The flow must be consistent with
required box-atmosphere purity levels, the scrubber, or the inert gas purification system that supports it. The
inert gas may be purged on a once-through basis or recirculated through a purification unit. Purification,
scrubbers, etc., should be protected with HEPA filters. Some of these systems are equipped with filters;
however, it should be noted how the filter is safely changed while maintaining a level of confinement.
Gloveboxes usually have filters installed for this purpose, the designer should assess the potential for
equipment contamination and cleanup.
7.5.3 Control and Instrumentation
Glovebox instrumentation may range from simple indicators and alarms to sophisticated control systems.
The type of control or instrument used will depend on the characteristics to be monitored, the relative
hazards, and the method and time available to correct an upset condition. Operational characteristics to be
measured and alarmed should always include the differential pressure between box and surroundings, the
filter resistance, the gas flow rate through the box, and the box atmospheric temperature. An alarm should
be available for any activity that could lead to degradation of or loss of confinement; fire; or any other safety
concerns. In addition to instruments and sensors on the box, it may be necessary to indicate and provide for
readouts and/or alarms at a central panel for oxygen content, liquid level, neutron flux, gamma flux, fire, and
explosive gas mixture inside the box.
When a monitored characteristic requires annunciation for safety when the level of a monitored parameter
passes some predetermined point, the alarm may be local. For example, an alarm may alert the operator to an
upset condition (e.g., when the glovebox pressure differential becomes less negative than its design relative to
the surroundings) or it may signal an annunciator panel in an adjoining “cold” area (e.g., by the entry door to
the glovebox room, in a control room, or both). Standard operating procedures and sufficient information
on the current contents of each box should be available to assist evaluation of the hazard area when an alarm
sounds and to aid in planning corrective action.
DOE-HDBK-1169-2003 Chapter 7
7-29
Section 28
Minimum instrumentation for a glovebox ventilation system should include devices to indicate the differential
pressure between the box and its surroundings, exhaust filter resistance, total exhaust flow rate, and exhaust
air temperature. Figure 7.17 shows the arrangement of indicating devices in a glovebox ventilation system.
The items shown above the double-dashed line indicate the types of instruments commonly used to
supplement the minimum instrumentation necessary to improve safety for a particular operation or
circumstance. For example, when box operators are not in full-time attendance for a continuous process, a
sensor can be provided to monitor abnormal pressure, temperature, or almost any other critical process
parameter and to actuate a remote alarm where an attendant is stationed. Figure 7.18 shows an example of a
local mounting for a differential pressure gauge (commonly referred to as a differential pressure gauge) on top
of a glovebox. The instrument should be mounted near eye level, and the indicating face should be located
so that the operator has a clear view while manipulating the gloves. The gauge display should make operating
conditions easily discernible to the operator (e.g., a differential pressure gauge with a range of 1 in.wc with
“0” at the top). Sensing lines should be short and should be sloped directly back to the glovebox so that
moisture will not pocket in the tube. Inline HEPA filters either should be located inside or as close to the
glovebox as possible to prevent contamination migration into the gauge lines and gauge. Tubing should be at
least 3/16 inch-diameter to allow the instrument to respond quickly to rapid changes in pressure. Use of a
three-way vent valve at the gauge permits easy calibration (zeroing) without disconnecting the sensing tube.
Calibration of glovebox differential pressure gauges should be done routinely.
Local Annunciator
Remote Annunciator
Adjustable Time Delay Device
Pressure-Electric Switch Sensing Normalcy
of Differential Pressure on Glovebox
Pressure-Electric Switch
Sensing Normalcy of
Exhaust Suction
Header Section
Differential
Pressure Gauge
Side Wall Static Tap
Pressure-Electric Switch
Sensing Normalcy of
Pressure Across Exhaust
Filter
High
High
High
High
Low
Low
Low
Low
Gauge Indicating Differential
Pressure Across Exhaust
Filter
Side Wall Static Tap
Side Wall Static Tap Temperature
Sensing Device*
Volume Flow
Rate Indicator
Alternate Location for
HEPA Filter
Connections for Aerosol
Testing of HEPA Filter
In-Box HEPA
Filter (Exhaust)Glovebox
Flame or
Pressure Sensor*
Backflow
Restrictive
Device (Optional)
Inlet Air Filter
Differential Pressure Gauge (Box to Room)
Instrumentation for
Specific Application
Minimum Instrumentation
* Applied where Specific Box Use Includes Flammable or Explosive Materials
to Actuate Alarm and Protective System
Figure 7.17 – Arrangement of Indicating Devices in Glovebox Ventilation System
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-30
Selection of a differential pressure gauge,
differential pressure gauge with switch, or
transducer should be determined by the
application. One advantage of using a
gauge is simplicity. A line is connected
across the upstream and downstream
plenums of a filter where the pressure drop
can be measured. Most gauges and
transducers install in this manner. A
differential pressure gauge with switch has
the addition of an alarm function. A
transducer allows multiple readouts and
greater accuracy, and can be used to
automate the exhaust system. It is more
costly, however, because it must have a
power supply, readout, and transducer.
The requirement for a gauge should be
Section 29
based on the actual system pressure. Exhaust filter pressure drops, for example, can vary up to 3 in.wg. If
the inlet filter housing valve is closed, the device will see the full negative capacity of the blower. The gauge
or transducer must have a proof pressure greater than the maximum system pressure (negative or positive) so
that it will not be damaged by excessive pressure.
Devices that measure pressure have a problem with “drift.” This occurs on most devices because of
continual pressure on the device. As a result, they must be recalibrated on a routine schedule. Liquid-filled
devices (manometers) are not recommended for glovebox pressure indicators; however, they have been used
to check the calibration of an existing device. Inlet filters on air-ventilated gloveboxes generally do not
require differential pressure gauges. The pressure drop across the inlet filter is approximately the same as the
box pressure.
A differential pressure gauge should be
provided for each exhaust HEPA filter stage
to indicate filter resistance. Pressure-sensing
connections can be provided to permit the
use of portable instruments. Suitable alarms
or controls that can function on small
pressure differentials (equal to 0.25 in.wg) are
difficult to keep calibrated and are often
expensive. Figure 7.19 shows a method for
indicating pressure drop through a filter.
Chapter 5, Section 5.6, gives some further
information on differential pressure
instrumentation.
Instruments used to measure airflow rates
from gloveboxes include an orifice plate,
venturi meter, flow nozzle, and calibrated Pitot tube. The important point is to use a simple, trouble-free
device that gives reliable readings within an accuracy of ±15 percent. When free moisture is absent, a Pitot
tube is the least expensive and most adaptable device for the small volume flow rates associated with
glovebox ventilation. Velocity pressure measurements (corrected for Pitot-tube single centerline location) for
airflows and duct sizes common in glovebox applications are given in Figure 7.20. The corrections shown
are for air at 60 degrees Fahrenheit and 14.7 pounds per square inch absolute (psia), and neglect the Pitot-
tube coefficient. Pitot tubes are available with coefficients of 1.00, but there is an advantage in using the
Figure 7.18 – Typical Local Mounting for
Differential Pressure Gauge
U-Bracket on Glovebox with
Gauge Mounted on Front Leg
(When Required Pressure Switches
are on Back)
Aneroid Type
Differential
Pressure Gauge
Three-Way
Vent Valve
1/4 or 3/8-in. OD
Sensing Line Sloped
Back to Box Connection
Glovebox
Three-Way Vent Valves
Static Probe or
Static Tube or
Sidewall Static
Tap
Aneroid Differential
Pressure Gauge
Tubing
Filter
Figure 7.19 – Indicating Pressure Drop through
a Filter
DOE-HDBK-1169-2003 Chapter 7
7-31
more common commercial Pitot tube with a coefficient
of 0.825 at low flow velocities. The equation for
measuring velocity with a Pitot tube is shown below.
V K (2gh)
1/2
,= (7.5)
where:
V = fluid velocity, ft/sec
K = coefficient of the pitot tube
g = acceleration of gravity, 37.17 ft/sec2
h = velocity pressure (ft) of the air-gas stream
The following equation is used for air at standard conditions:
V = 4005 K (hw)1/2 (7.6)
where:
V = fluid velocity, fpm
hw = velocity pressure, in.wg.
Section 30
A Pitot tube with a coefficient of 0.825 has a velocity pressure reading that is 1.47 times the velocity pressure
reading of the Pitot tube with a coefficient of 1.00 for the same fluid velocity. This pressure differential
allows the low velocities often encountered in glovebox ventilation to be measured more easily.
Figure 7.21 shows the arrangement of a round orifice in a straight section of metal duct. Either method
(Pitot tube or orifice) can be used to read the flow volume directly on a properly calibrated gauge. For a thin,
sharp-edge, round, concentric orifice with the
properties given in Figure 7.22, the flow rate can be
determined with sufficient accuracy for glovebox
applications by the following equation:
1 2 5 10 20 50 100 200 500 1000
2 3 4 6 8 1
0
1
2
-i
n
.
ID
D
u
c
t
Airflow Volume (scfm) at 60 ºF (~14.7 psi)
V
e
lo
c
it
y
P
re
s
s
u
re
R
e
a
d
in
g
(i
n
.w
g
)
1
0.5
0.2
0.1
0.05
0.02
.010
1
-i
n
ID
D
u
c
t
Figure 7.20 – Velocity Measurements
Aneroid Gauge Calibrated
to Read Airflow Volume
for the Particular
Orifice Used
Orifice
Low
High
Orifice Plate
Side Wall Static
Pressure Tap
Figure 7.21 – Orifice Meter Method of
Measuring Volume Flow Rate in Small Ducts
d
D
0.5 0.60D
0.6 0.53D
0.7 0.45D
x
Wall Tap
(See Detail Below)
16 ga (0.0625 in.) Plate
with Round Orifice
Between Flanges with
Thin Full Faced
Gaskets to Seal Joint
1/4 in. O.D. Tube
(0.0625 Wall),
1 1/2 in. Long
1/16 in. Hole in
Wall of Duct
* Sidewall Static
Pressure Tap
*
*
A
ir
F
lo
w
d1
d
1
6
d
P
re
fe
rr
e
d
1
d2
3
d
1
x
4
d
M
in
im
u
m
1
Figure 7.22 – Arrangement of Sharp-Edge
Concentric Orifice in Small Duct
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-32
Q =14 d2h1/2 (7.7)
where:
Q = airflow, cfm
d = orifice diameter, inch
h = pressure drop across orifice, in.wg
Assumptions inherent in the constant 14 used in equation (7.7) include: (1) air at standard temperature and
pressure, (2) flow coefficient for orifice = 0.65, and (3) ratio of orifice diameter to smooth-duct diameter,
D, 0.2 = d/D = 0.7. The practical use of this formula can be shown by the following example.
Determine the orifice size necessary for a 20-cfm airflow rate that would give a reading near the center of
scale on a 0- to 0.50-inch-range gauge.
Q 20 cfm
h
0.50
2
0.25 in.wg
d
Q
14h
20
14(0.25)
d 1.79 in.
1/2 1/2
=
= =
= =
=
(7.8)
For 3-inch schedule 10 stainless steel pipe (3.260-inch-diameter), the d/D ratio is 1.79/3.26 = 0.55, which is
within the acceptable range.
A shortcoming of the thin-plate orifice is loss of head of the air flowing through the device. Table 7.2 gives
the loss of head of concentric orifices for various d/D ratios.
Table 7.2 – Loss of Head for Various d/D Ratios
d/D ratio Fraction of Velocity Head Not Regained
0.2 0.95
0.3 0.89
0.4 0.83
0.5 0.74
0.7 0.53
In the example above, 0.70 × 0.20 = 0.14 in.wg is the pressure loss when 20 cfm flows through the orifice of
d/D = 0.55.
Immediately after installation and while filters are still clean, the measured pressure drop across the HEPA
filter can be used to check airflow to a high degree of accuracy by proportioning the measured pressure drop
to that stamped on the filter case at the time of predelivery testing. The pressure drop across the filter is no
longer a dependable indication of gas flow rate after the filter has accumulated dust. After a filter has been in
service for a period of time, it is necessary to measure both the pressure drop across the filter and the airflow
through it to evaluate the filter’s status and relationship to the whole ventilation system.
Section 31
DOE-HDBK-1169-2003 Chapter 7
7-33
Written procedures for periodically testing each alarm, control, and emergency system serving the glovebox
and its ventilation system are essential.
7.5.4 Challenge Aerosol Testing of Glovebox Filters
Testable HEPA filter installations must be tested
immediately after installation and then again periodically
to ensure that air cleanup capability and confinement
integrity remain intact. The principles of challenge
aerosol testing of HEPA filters are given in Chapter 8.
The HEPA filters used in glovebox systems are often
inconvenient to test because the challenge aerosol must
be injected into the inlet duct or glovebox. The
challenge aerosol cannot be fed into the inlet of the box
to test the exhaust-side filters if high-efficiency filters
are used in the inlet. Methods A and B (Figure 7.23)
require the challenge aerosol to be drawn into the
glovebox by the suction of the exhaust system.
However, the challenge aerosol should not be injected
into gloveboxes housing apparatus with open or
exposed optical lenses or with highly polished surfaces,
delicate balances, crystalline structures, sensitive
conductors, or similar equipment or products. In such
cases, the filter should be installed in the duct
downstream of the glovebox so that the injected
challenge aerosol will not back up into the glovebox
proper. Method C (Figure 7.24) may then be used for
challenge aerosol testing of the exhaust HEPA filter.
Where new or replacement exhaust filters are required
to be tested before restarting the ventilation system,
Method D (Figure 7.24) may be used. Note that in this
method the exhaust path from the glovebox is closed
and the challenge aerosol-air mixture for filter testing is
drawn from a separate valved path. The side path is
closed and sealed after testing is completed.
Methods A and B (Figure 7.23) require injection of the
challenge aerosol-air mixtures into the glovebox via
some convenient opening. A gloveport can be used if
confinement is not critical during testing. Otherwise, a
connection can be prepared (Figure 7.25), or an
alternate method can be devised. Methods C and D
(Figure 7.24) do not require the introduction of a
challenge aerosol into the glovebox. The challenge
aerosol inlet connection must be sized to pass the
challenge aerosol or challenge aerosol-air mixture. The
connection for concentrated challenge aerosol in
Method C must admit 2 to 5 cfm, while the connection
in Method D must accommodate the total challenge
aerosol-air mixture used for the test.
Figure 7.23 – Methods of Injecting Test
Aerosol and Extracting Samples
(Method A and B)
Method A
Method B
DOP In
DOP in via Controlled
(Valved) Penetration
Glovebox
Upstream Sample
Upstream
Sample
Downstream
Sample
Downstream
Sample
HEPA Filter
HEPA Filter
Method C
Method D
DOP In
Glovebox
Upstream
Sample
DOP In
Upstream
Sample
DOP Air
Mixture In
Downstream
Sample
Downstream
Sample
HEPA Filter
HEPA Filter
Valve Closed During Test
Flow During Test
Supplied by Alternate
Exhaust Path
Figure 7.24 – Methods of Injecting Test
Aerosol and Extracting Samples
(Methods C and D)
Nuclear Air Cleaning Handbook U.S. Department of Energy
7-34
7.5.5 Glovebox Shielding
Section 32
Some gloveboxes may require gamma, beta,
and neutron shielding because of the nuclides
used and the amounts of material involved.
Boxes handling kilogram quantities of
plutonium can be shielded by providing lead-
impregnated gloves, glovebox shielding (water
or any other similar mass), lead glass over the
windows, and lead-hinged plugs or covers
over the ports. The operating, shielding,
removal, and replacement requirements of the
glovebox HEPA filter must also be
considered when glovebox shielding is
required. The thickness of the shielding
affects the design of the filter housing used on
this type of glovebox. The designer should
account for this by extending the service
fittings (pressure measurement) and any other
glovebox pass-through used in the design.
This practice is also mandated for bagging
ports used to remove the primary HEPA
filters and the cover doors. Ergonomic
operations inside shielded gloveboxes should
be given careful consideration because lead-lined gloves and dimensional differences make manipulations very
difficult.
7.5.6 Seismic Design Considerations
By their very nature, gloveboxes are typically top heavy. This presents some unique challenges when
designing the supports and holddowns for the systems during a postulated seismic event. Several facilities
have had to redesign their support systems after the facility was operating. This led to many obstructions and
interferences which could have been avoided at an earlier design stage. For seismic considerations in DOE
facilities, see Chapter 9.
7.5.7 Criticality Considerations
When criticality is a potential concern for glovebox design, care must be taken in providing for the
appropriate geometry control and water use restrictions. Drains, in particular, must be designed with great
care. The buildup of fissile material on the HEPA filters must also be considered.
Figure 7.25 – Connection for Introducing Test
Aerosol into Glovebox
Plugged Female Connector
for Aerosol Generator Hose
GloveboxGlovebox
Vertical Position Pipe
Sized to Achieve Needed
Test Flow
DOE-HDBK-1169-2003 Chapter 7
7-35
7.6 References
1. AGS (American Glovebox Society), 1998, Guidelines for Gloveboxes, AGS-G001 (Second Edition),
Santa Rosa, CA.
2. ASME (American Society of Mechanical Engineers), 2003, Code on Nuclear Air and Gas Treatment, ASME
AG-1, New York, NY.
3. DOE (U.S. Department of Energy), 1999, Fire Protection Design Criteria, DOE-STD-1066,
Washington, DC, July.
4. ASHRAE (American Society of Heating, Refrigeration and Air Conditioning), 1973, Handbook and Product
Guide – Systems, New York, NY.
5. ASME (American Society of Mechanical Engineers), 1989, Testing of Nuclear Air Cleaning Systems, ASME
N510, New York, NY.
6. DOE (U.S. Department of Energy), 2000, Facility Safety, DOE Order 420.1, Washington, DC, November.