DOE-STD-3025-2007, Quality Assurance Inspection and Testing of HEPA Filters
Functional areas: Quality Assurance, HEPA Filter, Performance Testing
This standard establishes essential elements of a Department of Energy (DOE) program for quality assurance inspection and performance testing of High Efficiency Particulate Air (HEPA) filters to be installed in DOE Nuclear facilities that fall within the scope of DOE-STD-3020, Specification for HEPA Filters Used by DOE Contractors. Supersedes DOE-STD-3025-99
Supersedes:
Superseded By:
Cancels:
DOE-STD-3022-98, DOE HEPA Filter Test Program on Feb 12, 2007
DOE-STD-3026-99, Filter Test Facility Quality Program Plan on Feb 12, 2007
Version history and related documents
Superseded by
A newer version replaces this document.
Supersedes
Earlier documents this one replaced.
Document text
Text extracted from the attached file. Refer to the original document for the authoritative version.
Section 1
fos
NOT MEASUREMENT
SENSITIVE
DOE-STD-3025-2007
February 2007
Supersedes
DOE-STD-3025-99
DOE TECHNICAL STANDARD
Quality Assurance Inspection and Testing of
HEPA Filters
U.S. Department of Energy AREA SAFT
Washington, D.C. 20585
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited
DOE-STD-3025-2007
FOREWORD
This U.S. Department of Energy (DOE) standard supersedes DOE-STD-3025-99 and is approved
for use by DOE and its contractors. In 2005, DOE privatized its quality assurance inspection and
performance testing of High Efficiency Particulate Air (HEPA) filters and now contracts for
these services. As a result, DOE-STD-3022-98, DOE HEPA Filter Test Program and DOE-
STD-3026-99, Filter Test Facility Quality Program Plan, are no longer required and will be
cancelled.
This standard was developed primarily for application in DOE programs. This standard
establishes essential elements of a DOE program for quality assurance inspection and
performance testing of HEPA filters to be installed in DOE nuclear facilities that fall within the
scope of DOE-STD-3020-2005, Specification for HEPA Filters Used by DOE Contractors. This
standard was designed to achieve technical coordination among individuals of recognized
authority from affected DOE programs, including manufacturers, purchasers, users, and technical
experts. A standard working group comprised of subject matter experts drawn from DOE,
Defense Nuclear Facilities Safety Board, contractors, and industry was used to prepare the
standard.
Beneficial comments (recommendations, additions, deletions) and any pertinent data that may
improve this document should be sent to Dr. Subir K. Sen, U.S. Department of Energy, Office of
Corporate Safety Programs HS-31/270 CC, 1000 Independence Avenue, SW, Washington, D.C.
20585.
DOE technical standards, such as this standard, do not establish requirements. However, all or
part of the provisions in a DOE standard can become requirements under the following
circumstances:
63) they are explicitly stated to be requirements in a DOE requirements document; or
(2) the organization makes a commitment to meet a standard in a contract or in an
implementation plan or program plan required by a DOE requirements document.
Throughout this standard, the word “shall” is used to denote actions that must be performed if
the objectives of this standard are to be met. If the provisions in this standard are made
requirements through one of the two ways discussed above, then the “shall” statements would
become requirements. It is not appropriate to consider that “should” statements would
automatically be converted to “shall” statements as this action would violate the consensus
process used to approve this standard. This standard in part incorporatés the HEPA testing
requirements described in the Secretary of Energy’s June 4, 2001 letter /00 Percent Quality
Assurance Testing of HEPA Filters At The DOE Filter Test Facility to the Defense Nuclear
Facilities Safety Board.
DOE-STD-3025-2007
Section 2
TABLE OF CONTENTS
FOREWORD ......ccccccesssssesceeteesesceseeecsccescaeesesaeenecsessessceeaessrsnessessesseseseseaeteeeneaseseeensaenesy 2
1. SCOPE w.ececccccccccccccscssecsscseccsecsacceseneceressesaceescesseeseesseessaeceeseessesaeeseseaesssneeaeesreseeees 4
2. APPLICABLE DOCUMENTS .......cccccecceeeeeesecseeeeenseeecerceseeceseeseseeateensareneennees 4
2.1 Federal Regulations, Department of Energy Standards and
Publications ........ccccccesecessseeseneesseeecsenececseneeeeceeeeeseeersreseteeesseeestiieeeniaeeeetees 4
2.2 Other Standards... ceccceccccecteeeesenteeeeeeeessneeesceaeeeesenceeeesesiaeesseesaeeerereees 4
3. DEFINITIONS ......ccecccscsssscsessnesseecnsenseceecaeesetceeecceecaeessesseceeecaeseaesenssesecatessaceesenae 5
4. GENERAL REQUIREMENTS .......ccccceecessscessesseeeseceeeeaeenecenecseseneseneenaevaneeteseeed 7
4.1 DOE HEPA Filter Procurement Program ..0......ccceceeeeseeeeeeeseeeeeeeesneeseeeeees 7
4.2 Qualification of HEPA Filters to be Installed in Nuclear Facilities .......... 7
4.3 Quality Assurance Inspection and Performance Testing of HEPA
Filters at DOE Approved FTF ..0.... eee eee cece eee ene certs eeeeseeeeeeeseeeeaee 7
4.4 Minimum Operating Procedure Requirements for Primary
FTF functions oo... .ecceececececesccencceeneeeseeesseeecsneceseeceeeeseeesaseeseveaeeeeeseaeesseneeens 7
4.5 Site Receipt Inspection 0.0... ce eeeecesseeceseeceeseceeeseeeseeeesseceseeesaeesseetsneerseeeees 8
5. FILTER TEST FACILITY PROCEDURES. 000... cceeceeceeeseeeeecseereeeeeeeeeseeneeeaes 8
5.1 Receipt of Filters 0... eeeecseeeseeeececesseceneeeeeeecseeeaeeescesesereeaeseeseesuneeenes 9
5.2 Penetration and Resistance Testing .............ccccccccsccscessesseeseeesecesseaseeseeesaees 9
5.3 Inspection and Test Reports and Labeling... eee eeeeceeeeeeeeeeeeneeeeees 11
5.4. FTF Personnel 0.0... eeceeeeeeesececeeeeeeceseeesaeeeseeeeaeeeeecaeseseseneersaeeetseesneetees 12
5.5 Reports ......ee eee eccccesseeeeseeceeeeetenceceeaeeseeaaeeessaeeesseeesaeecseesenaeeeseneeeseeaeeens 14
5.6 Contacts with Filter Manufacturers oo... eeeseeseceeceeceeeeneeeeeseeeenees 14
5.7 Waiver and Filter Media Repair .........eccccccccccccesccssceessececsensecsseeseersesaeenses 15
5.8 Equipment Maintenance and Calibration 0.0.0.0... cecececeeeeseeeeeeeetsseseeeees 15
5.9 Quality Assurance Program .........ccccecccescessesseesssessenecessesecesecsessaesseeesseeaees 15
5.10 Document Control and Records Management ...........c.ccccceseeseeestecesseeeees 15
APPENDIX 1 - HEPA FILTER TEST REPORT ........ccccccccccsccesecsecsscessesseeeseessecnseeeses 16
APPENDIX 2 - LABEL EXAMPLES .0.....ccccccccccecessccessscecessecceatecseasessseceessseeenssscessnees 18
APPENDIX 3 - MONTHLY AND SEMIANNUAL REPORT FORMAT .............0. 19
1.
2.
DOE-STD-3025-2007
SCOPE
This standard establishes essential elements of a Department of Energy (DOE) program for
quality assurance inspection and performance testing of High Efficiency Particulate Air
(HEPA) filters to be installed in DOE nuclear facilities that fall within the scope of DOE-
STD-3020, Specification for HEPA Filters Used by DOE Contractors. Quality assurance
inspection and performance testing shall be performed at a DOE approved filter test facility
(FTF) prior to HEPA filter installation. This standard describes the operational requirements
and procedures in performing HEPA filter quality assurance inspection and performance
testing.
APPLICABLE DOCUMENTS
Section 3
The following documents either form a part of this standard to the extent specified herein
or specify requirements for HEPA filter qualification, quality assurance inspection, or
testing. Unless otherwise stated, the current issue date and revision number of a
referenced document shall apply, including addenda and/or amendments. In the event of
a conflict between provisions of this standard and provisions of the "Other Standards” in
Section 2.2, the text of this standard shall take precedence. The Application Guide in
subpart 4.5 of ASME NQA-1-2004 describes how ASME NQA-1-2000 addresses the
DOE quality assurance requirements.
2.1 Federal Regulations, Department of Energy Standards and Publications
10 CFR Part 830, Nuclear Safety Management
DOE O 414.1C, Quality Assurance
DOE-STD-3020, Specifications for HEPA Filters used by DOE Contractors
2.2. Other Standards
ASME AG-1, Code on Nuclear Air and Gas Treatment
ASME NQA -1, Quality Assurance Program Requirements for Nuclear
Facilities
IEST-RP-CC007.1, Testing of ULPA Filters
IEST-RP-CC001.4, HEPA and ULPA Filters
MIL-STD-282, Filter Units, Protective Clothing, Gas-Mask Components, and
Related Products Performance - Test Methods
DOE-STD-3025-2007
3. DEFINITIONS
Airflow: Airflow expressed in terms of actual cubic feet of air per minute (acfm). Actual
cubic feet per minute is a cubic foot of air at actual existing conditions.
Airflow Resistance: The resistance to airflow at the manufacturer rated airflow of the
clean filter when tested in accordance with ASME AG-1, FC-5000.
Approved Test Aerosols: Particle-generating materials approved by DOE for
penetration testing. Test aerosols approved by the DOE for tests conducted in the FTF are
di-octyl phthalate (DOP), also known as DEHP, and di-octyl sebacate (DOS), also known
as DEHS. Others may be approved after DOE evaluation. Polystyrene latex (PSL) with
0.3 micrometer diameter may also be used only when testing HEPA filters made with
glass fiber media in accordance with IEST-RP-CC007.1. The DOP and DOS aerosols
can be thermally generated to produce 0.3 micrometer aerosols using a penetrometer.
Alternatively, a Laskin nozzle can be used to generate heterodisperse DOP and DOS
aerosols and a laser particle counter used to measure the 0.3 micrometer aerosols.
Effective Filter Media Area: The effective surface area of the filter media in the
assembled filter element (without adhesive areas) through which the air stream is passed.
Filter Media Face Velocity: The rated airflow divided by the effective filter media area.
Filter Test Facility (FTF): A facility contracted by DOE specifically to conduct quality
assurance inspections and tests of HEPA filters.
Filter Tester: A test apparatus for determining filter penetration and pressure drop as
described in MIL-STD-282 and IEST-RP-CC007.1.
High Efficiency Particulate Air (HEPA) Filter: A throwaway, extended-media, dry
type filter with a rigid casing enclosing the full depth of the pleats. The filter shall
exhibit a minimum efficiency of 99.97% at a test aerosol diameter of 0.3 micrometer.
Nuclear Facility: A reactor or nonreactor nuclear facility where an activity is conducted
for or on behalf of DOE and includes any related area, structure, facility, or activity to the
extent necessary to ensure proper implementation of the requirements established by 10
CFR Part 830.
Penetration: The downstream test aerosol concentration, expressed as a percentage of
the upstream test aerosol concentration.
Section 4
Penetrometer: A self-contained instrument for the determination of filter penetration and
pressure drop using a thermally generated liquid test aerosol with diameter of 0.3
micrometer and a light scattering photometer in accordance with MIL-STD-282.
Preparing Activity: The activity performed by the DOE organization responsible for
issuance and interpretation of this standard.
DOE-STD-3025-2007
Qualified Filter: HEPA filter designs that have successfully passed qualification or
requalification testing performed and certified by an independent test laboratory in
accordance with ASME AG-1.
Rated Airflow: The designated airflow capacity of a HEPA filter in acfm.
Standard Orifice Plate: An air flow measurement device having multiple holes that is
used for calibrating the air flow in the filter tester.
DOE-STD-3025-2007
4. GENERAL REQUIREMENTS
4}
4.2
4,3
4.4
DOE HEPA Filter Procurement Program
HEPA filters for installation in a DOE nuclear facility that fall within the scope of this
standard shall be fabricated, inspected, and tested by the manufacturer to the
requirements in DOE-STD-3020.
Qualification of HEPA Filters to be Installed in Nuclear Facilities
HEPA filters that fall within the scope of this standard shall be "Qualified" in
accordance with DOE-STD-3020 and ASME AG-1.
Quality Assurance Inspection and Performance Testing of HEPA Filters at DOE
Approved FTF
Prior to installation in a DOE nuclear facility, HEPA filters that fall within the scope of
DOE-STD-3020 and require quality assurance inspection and testing as directed by the
Secretary's June 4, 2001 memorandum, /00 Percent Quality Assurance Testing of
HEPA Filters At The DOE Filter Test Facility, shall be inspected and tested by an
independent DOE approved FTF.
Minimum Operating Procedure Requirements for Primary FTF Functions
HEPA filters that require inspection and testing at a DOE approved FTF shall be
inspected and tested at an independent facility in accordance with Section 5 of this
standard, the purchaser’s written specifications or procurement documents, and any
special written instructions from the purchaser. Unless otherwise instructed, FTF
inspections and tests shall include:
e Visual inspection for compliance with purchase order (e.g., type, size, quantity
received, and shipping damage).
e Visual inspection for manufacturing defects and compliance with construction
and materials requirements.
e Penetration test at 100% rated airflow for all filters and penetration test at 20% for
filters with rated airflow of 125 acfm (0.059 m?/second) and higher.
e Airflow resistance at 100% of rated airflow.
Maximum penetration allowed is 0.03% at an aerosol particle diameter of 0.3
micrometers. If a higher penetration is measured, the filter shall be rejected and
purchaser notified in writing with the test results that the filter does not meet the
penetration requirements.
Maximum airflow resistance, at rated airflow, is listed in Tables 5.1, 5.3, 5.4, and 5.5 of
DOE-STD-3020. The resistance shall be reported to the nearest 0.1 inch (in) water
gauge (wg) (25 Pa).
DOE-STD-3025-2007
4.5 Site Receipt Inspection
Purchaser shall conduct site receipt inspection of HEPA filters using qualified
inspectors with specific training for HEPA filters. HEPA filter containers shall be
inspected for shipping damage prior to or immediately after unloading. Each purchaser
shall develop detailed inspection criteria. The inspection criteria should include the
following:
Section 5
Filter orientation and packaging.
Filter size, model, type and capacity.
Filter labels, markings, and identification.
Filter faceguards and separators, when applicable.
Filter frame, including frame edges, for damage and roughness.
Filter media damage, including punctures, tears, cracks, holes in the filters,
sagging pleats, etc.
Filter seals and gasket damage, including tears, splits, gaps, poor adhesion, etc.
Filter dimensions and squareness of the frame.
Documentation from filter manufacturer as specified in the purchase order
including certificate of qualification per Section 4.2.
Documentation from the FTF per Section 5.3.
5. FILTER TEST FACILITY PROCEDURES
All FTF operations shall be conducted in accordance with written procedures that address the
subjects and conform to this standard. All procedures shall contain specific acceptance
criteria. The FTF shall prepare, maintain, and operate in accordance with detailed procedures
that comply with DOE-STD-3020 and cover, as a minimum, the following functions:
Receiving inspection.
Un-boxing, handling, re-boxing, and storage of filters.
Inspection for defects, damage, and compliance with purchase order specifications.
Documentation and records keeping as specified in the FTF contract.
Operating and calibration procedures for each penetration and resistance test device.
Test and inspection reports, including disposition and retention.
Labeling of accepted and rejected filters.
Segregation and disposition of rejected filters.
Shipping of accepted filters.
Preparation of monthly and semiannual reports to DOE.
Training and qualification of personnel.
DOE-STD-3025-2007
5.1 Receipt of Filters
5.1.1
5.1.2
Receiving Inspection
All filter packages, crates, and pallets shall be inspected upon receipt at the
FTF. Any damage must be noted on the Bill of Lading before signing. Damaged
cartons or cartons improperly oriented shall be opened immediately and the
filters inspected, and a description of observed damage shall be recorded in the
filter inspection and test report.
Initial Handling and Storage
Filter handlers shall be properly trained to handle filter cartons carefully.
Cartons shall be oriented with arrows on the filter cartons pointed "up". Filter
cartons shall be stacked not more than three (3) high, and pallets shall not be
stacked on top of one another or other material stacked on top of HEPA filter
pallets. HEPA filters shall be stored in a clean, dry location. Storage facilities
for HEPA filters shall be equipped with temperature controls to meet storage
requirements specified in DOE-STD-3020.
Pre-Test Filter Inspection
Prior to testing, each filter shall be visually examined for possible damage,
compliance with applicable sections of DOE-STD-3020 and purchaser’s
specifications, and workmanship. Damage to filters noted during the pre-test
inspection shall be recorded on the filter inspection and test report. Filters
obviously damaged shall not be further tested, but shall be immediately reported
to the purchaser for disposition.
The inspection shall, at a minimum, include: verification of general
workmanship, filter type, size, gasket installation and material, separators,
frame dimension and material, squareness, parallelism of media face, face
guards, and required labels or markings. Filters shall be inspected for looseness
of filter packs, excessive slump or distortion, loose gaskets, breaks or tears, or
patching of the filter media. Manufacturer’s labels shall contain test data, test
date, and effective filter media area.
Section 6
5.2 Penetration and Resistance Testing
5.2.1
Testing Requirements and Test Methods
Following visual inspection, each filter, completely encased in the test
apparatus, shall be tested for penetration at 100% of the rated airflow, and filters
rated at 125 acfm (0.059 m°/second) or greater shall also be tested at 20% of
rated airflow. For encapsulated (nipple ended) filters, a special housing may be
required to ensure the filter is encased within the test apparatus. Each filter shall
be tested for resistance to airflow at 100% of the rated airflow. Test air flow
rates shall be measured in actual cubic feet per minute (acfm), and conversion to
9
5.2.2
DOE-STD-3025-2007
standard cubic feet per minute (scfm) is not required. The filter test apparatus
shall be equipped with "chucks" which encase the HEPA filter in the test
position. Encapsulated (nipple ended) filters shall not be routinely tested for
resistance to airflow. Operating, calibration, and test procedures shall be
prepared for each test device and shall include, as a minimum, the following
elements:
e Filling the generator reservoir and verification of fluid level.
e Daily verification of airflow rates using National Institute of Standards
and Technology (NIST) traceable orifice plates. Flow rates shall be
adjusted such that the inclined manometer reading is within +/- .02 in.
weg of the orifice plate calibration value.
e Adjustment and verification of critical airflows (and temperatures for
thermal test method only).
e Calibration of filter test equipment which determines particle size,
penetration, and resistance.
e Calibration of instruments which are used to calibrate the filter test
equipment.
e Calibration schedules.
e Design and use of adapters to permit tests of non-standard filters or
special test procedures.
e Operation, service, and maintenance of test equipment, including the
system exhaust air cleaning device.
For penetration and resistance testing, two (2) Penetrometer Systems have long
been authorized. Both Penetrometer Systems operate using approved test
aerosols. They are:
e The Q-107 for testing filters with rated airflows greater than or equal to
250 acfm (0.12 m*/second).
e The Q-76 for testing filters with rated airflows less than 250 acfm (0.12
m*/second).
Approved Test Aerosols
Test aerosol materials currently approved by DOE for HEPA filter penetration
testing are di-octyl phthalate (DOP) and di-octyl sebacate (DOS). Polystyrene
latex (PSL) spheres with 0.3 micrometer diameter may also be used only when
testing HEPA filters made with glass fiber media in accordance with IEST-RP-
CC007.1.
10
DOE-STD-3025-2007
5.3. Inspection and Test Reports and Labeling
5.3.1 FTF Inspection and Test Reports for HEPA Filters
Upon completion of quality assurance inspections and performance tests, the
FTF shall provide a written report of test data to the purchaser (see Appendix 1).
Reasons for rejection of any filters shall be included in the report and rejected
filters specifically identified. The report shall include, as a minimum:
Identification of the FTF.
Name of purchaser.
Purchaser order number.
Date of shipment receipt at FTF.
Date of inspection and test.
Purchaser’s specification or standard (if applicable).
Filter manufacturer.
Filter description (model or designation number).
Rated airflow.
Test air temperature.
Test relative humidity.
Barometric pressure at time of test.
Name of operating technician and supervisor responsible for test.
Serial number of each filter tested.
Resistance (in. wg or Pa) across filter pack at rated airflow.
Penetration test at 100% rated airflow for all filters. ;
Penetration test at 20% for filters with rated airflow of 125 acfm (0.059
m?/second) and higher.
Remarks: Reason for rejection.
o P= Penetration
o R=Resistance
o D=Damage: specify
o O= Other: as described in Part 2 of Appendix 1
Section 7
5.3.2 Labeling
Accepted Filters: Each accepted HEPA filter shall be identified with a properly
secured "Accepted" label (yellow). A suggested "Accepted" label design is
shown in Appendix 2, and includes the following:
Identification of FTF.
Filter serial number.
Resistance at rated airflow.
Penetration test at 100% rated airflow for all filters.
Penetration test at 20% for filters with rated airflow of 125 acfm (0.059
m?/second) and higher.
Date tested.
il
DOE-STD-3025-2007
Rejected Filters: Each rejected HEPA filter shall be identified with a properly
secured "Rejected" label (red). A suggested "Rejected" label design is shown in
Appendix 2. This label can be a single or double sided label and shall be
attached to the filter.
5.4 FTF Personnel
All personnel who inspect, test, supervise, or interpret the results of inspections and
tests of HEPA filters at the FTF shall be qualified in accordance with Section 5.4.1 of
this standard. Non- FTF personnel who handle HEPA filters, including shipping,
receiving, and materials-handling personnel, shall, as a minimum, be instructed in the
requirements for proper handling, stacking, and storage of HEPA filters.
5.4.1
Qualification
The FTF shall ensure that personnel selected to conduct, supervise, or interpret
the results of FTF inspections and tests are qualified by experience, formal
training or instruction, and are physically capable of carrying out the functions
for which they are responsible.
Personnel assigned to handle the HEPA filters shall be instructed in the proper
procedures for:
e Handling, stacking, storing, un-boxing, re-boxing, crating, and placing
filters on pallets.
e Operation of appropriate materials handling equipment, such as fork-lift
industrial trucks, hoists, or conveyers.
e Verifying compliance with qualification requirements by supervisor
review of records.
e Inspection for shipping damage, correct orientation, and proper stacking
at time of receipt.
e Preparing of filters for shipping, including the proper orientation,
packaging, and proper loading in transport vehicles.
Personnel responsible for the inspection and testing of HEPA filters, the
supervision of inspection and testing activities, or the interpretation of
inspection and test results, shall have formal training and demonstrated
performance or comprehension in the following:
e All applicable provisions of this standard.
e Applicable specifications for HEPA Filters used at DOE nuclear
facilities.
e Materials, construction, and performance specifications of HEPA filters.
e Use and interpretation of filter specifications and purchase criteria, with
particular attention to ASME AG-1 Code, Section FC and FK, and
Institute of Environmental Sciences publication IEST-RP-CC007.1.
e Performance specifications for and calibration of test devices and other
instruments used at the FTF.
e Procedures for handling, inspection, testing, data recording, labeling,
and disposition of accepted and rejected filters.
12
5.4.2
5.4.3
5.4.4
DOE-STD-3025-2007
e Proficiency in the operation, adjustment, and maintenance of the FTF
instruments and equipment.
e All applicable Quality Assurance requirements (1.e., DOE O 414.1C and
NQA-1).
Section 8
Personnel responsible for interpretation or certification of inspection and test
results shall, in addition, have demonstrated proficiency in the following:
e Data evaluation and analysis, including validation of test results.
e Interpretation of applicable standards, specifications, and purchase-order
requirements relative to the acceptability of filters.
e Determination of the appropriate rejection status when compliance with
all specified requirements cannot be demonstrated.
e Preparation and issuance of appropriate documentation of inspection and
test results.
e Materials of construction and certifications, and compliance of filters to
such certifications.
e Personnel in this category have the authority to sign data forms and
reports attesting to the accuracy and completeness of the reported data or
results.
Physical Qualifications
Personnel responsible for supervision of inspection and testing activities or for
interpretation of inspection and test results shall meet appropriate physical
qualifications. They shall include the following:
e Visual acuity, including near vision, depth perception, and color
discrimination.
e Physical capability for performing job related tasks.
e Hearing acuity.
Training
Personnel responsible for HEPA filter inspection and testing, supervision of
inspection and testing activities, or the interpretation of inspection and test
results, shall satisfactorily complete a formal training course. This course shall
address the principles of HEPA filter testing. The course shall be equivalent to
the Harvard University School of Public Health In-Place Filter Testing
Workshop. New hires shall receive on-the-job training and instruction by
qualified personnel to become completely familiar with the equipment,
instrumentation, and procedures. FTF management is responsible for
establishing ongoing personnel maintenance and re-certification programs that
assure personnel remain qualified to carry-out required FTF activities.
Documentation
Physical and technical qualifications of personnel responsible for inspection and
testing, supervision of inspection and testing activities, and interpretation of
inspection and test results, shall be documented. Documentation shall include
13
5.5.
5.6
DOE-STD-3025-2007
written evidence of the dates and extent of instruction and formal training, and
shall be signed by a responsible supervisor. The supervisor’s signature will
certify satisfactory demonstration of the individual's ability to perform all job
functions.
Personnel records shall be retained for the duration of the FTF contract and as
specified in Section 5.10, and shall be subject to audit and recertification by
demonstration as specified by facility procedures. Recertification will be
required at intervals to be defined in facility operating procedures.
Reports
The FTF shall prepare a monthly and semi-annual report describing test activities for
that period, including a tabulation of test data as described below. Copies shall be sent
only to the DOE as specified by the FTF contract. Further distribution of HEPA filter
test data shall be at the discretion of DOE.
5.5.1 Test Data Summary
A summary of HEPA filter test data during the report period shall be presented
in table form separated by filter model type and so recorded. As a minimum, the
tabulation shall provide the following data for each HEPA filter tested:
e Name of purchaser.
Name of filter manufacturer.
Purchase order number.
Rated airflow acfm.
Number of filters received.
Number of filters tested.
Number of filters accepted.
Number of filters rejected.
Reason for rejection [as specified in Appendix 3].
Section 9
5.5.2 Report Format
The format of the monthly and semiannual reports shall be as specified in
Appendix 3. Narrative information, including explanations of trends or
problems observed during the report period, shall also be provided.
Contacts with Filter Manufacturers
FTF contact with HEPA filter manufacturers shall preclude the potential for conflicts of
interest. When questions arise regarding HEPA filters being tested by the FTF,
contacts between the FTF and filter manufacturers will normally be limited to the
following: (1) notices of shipping damage; (2) responses to manufacturer's requests for
information about filter receipt and test schedules; and (3) queries by the FTF
concerning manufacturer's instructions for disposition of rejected filters.
14
5.7
5.8
5.9
5.10
DOE-STD-3025-2007
Waiver & Filter Media Repair
Filter testing shall be performed as specified in DOE-STD-3020. When authorized and
agreed to in writing by the purchaser and the FTF manager, the FTF may accept minor
deviations from certain specification provisions, provided that the minor deviations do
not affect the basic performance of the filter. However, HEPA filters that fail
penetration or resistance tests shall not be accepted with waiver, nor shall the FTF
attempt to repair damage to the HEPA filter media. It shall be the responsibility of the
purchaser and manufacturer to determine disposition of those filters that do not pass
either penetration or resistance test.
Equipment Maintenance and Calibration
FTF equipment (e.g., pressure and temperature measurement instruments, orifice plates,
mass-flow meters, and other instruments critical to the performance of tests) shall be
properly maintained and calibrated using qualified personnel and NIST traceable
standards. Calibration reports and certifications shall be maintained by the FTF and
shall be available to DOE upon request.
Quality Assurance Program
The FTF shall establish, maintain, operate, inspect, and test HEPA filters in accordance
with a Quality Assurance Plan that conforms to DOE O 414.1C and ASME NQA-1.
Document Control and Records Management
The FTF shall maintain controlled access to all stored records of data and other
technical information generated in the performance of quality assurance inspection and
performance testing of HEPA filters. Documents shall be maintained in a safe and
secure manner to prevent tampering and water or fire damage. The FTF shall transfer
to DOE all data and records at the conclusion of the contract period in accordance with
the contract provisions. These shall include, but are not limited to, personnel
qualification records, logs of HEPA filter tests, and instrument calibration records.
15
DOE-STD-3025-2007
APPENDIX 1 - HEPA FILTER TEST REPORT
PENETRATION AND RESISTANCE TEST RESULTS (Part 1)
| NUMBER
PURCHASER ORDERED DATE RECEIVED
DOP
% @ RATED FLOW % @ 20% RATED
NUMBER DATE TESTED
PURCHASE ORDER NO. RESISTANCE RECEIVED
in. 100% RATED FLOW
NUMBER DATE SHIPPED
FILTER MODEL NUMBER SPECIFICATION ACCEPTED
MANUFACTURER
FILTER DESCRIPTION TEMPERATURE | TEST FLOW (acfm) PENETRATION | RESISTANCE
oF
PO REVIEWED BY RATED FLOW BAROMETRIC TEST AIR HUMIDITY DAMAGE OTHER
(acim) PRESS IN % RH
mm
TEST RESULTS
FILTER INSPECTION RESULTS RESISTANCE % PENETRATION
SERIAL (in. wg) @ 100% FLOW | @ 20% FLOW
NUMBER
1
2
3
4
5
6
7
8
9
-ajalalsalajraleal]a
NT OD] O?} el] wy nya] oa
18
DISTRIBUTION
TESTED BY:
APPROVED BY:
16
Purchaser:
DOE-STD-3025-2007
APPENDIX 1 - HEPA FILTER TEST REPORT
Section 10
VISUAL INSPECTION CHECK LIST (Part 2)
P.O#:
Date:
Specific Reference for Acceptance Criteria:
RECEIVING INSPECTION
Number of Filters Per Shipping Papers
Filters Received Upright (pleats vertical)
Cartons/Filters Undamaged
Crates/Pallets Undamaged
Characteristics As Specified In Purchase Order or Specifications:
Number of Filters
Frame Material
Frame Construction
Gaskets: Type .
Location/Size
Construction
Capacity
UL-586 Label
Faceguards
Separators
Required Labels/Marking/Identification
Exposed Edges of Frame Sealed
Frame Edges/Faces Free of Splinters/Rough Edges-------------
Gaskets Secure and Undamaged
Fluid Seal Gasket Undamaged
No Damage to Filter Media
Filter Dimensions
Squareness of Frame
Hidden Shipping Damage
Filter Pack Tightness
Filter Workmanship
Other:
Comments:
Inspected by: Name
Approved by. Name
17
Satisfactory
L|
LILI
Satisfactory
eee eee
Unsatisfactory
LI
LIL
Unsatisfactory
HIDUUUOOOUID I
N/A
LILI
z
>
/
LILUUOOOOOUUEU
DOE-STD-3025-2007
APPENDIX 2 -LABEL EXAMPLES
Accepted Label (Yellow)
FILTER TEST FACILITY
Address
DOE Contract:
Filter Serial Number:
FILTER TEST RESULTS
Resistance
(in. weg)
% Penetration
at 100% Flow
% Penetration
at 20% Flow
Date of test
Rejected Label (Red)
Front
REJECTED
FILTER TEST FACILITY
Address
[ Inspector: Date:
Rejected Label (Red)
Back
Date:
PO Number:
Purchaser:
% Penetration
Filter - ae Resistance
Findings * : 100% Flow 20% Fiow
Ser No. (in. wg)
* Rejection Codes
F — Frame
FG — Face Guards
CD - Carrier Damage
FP — Filter Pack
G — Gasket
M ~ Media
P - Penetration
R-— Resistance
Note: Rejected label can be a single or double sided label.
18
61
12301
1e}0}qNS
18}03qNS
9edg
eBeweg iojpue spoojog (%) (Bm ‘ul) (uyoe)
Buiddiyg | Od joow | Buunjoejnuew | uoyjesjeueg | aourjsisay | peyefey | peydesoy | pajsel | pealevey Mold Jequinn Jaunjorynuey Jaseyound
you se0q 40qunN Joquinyn | jaquiny | Jequinn pee Od
uonoelay 10} uoseay
‘popraoad oq osye jyeys ‘oAneueu Aue Surpnyout ‘syiodal enuuerues pue AjyUOW oy} Jo sjoodse
IOYIO ‘SIsATeUe IO} BYP SuLoVIXa AFTTCUIIs [[LM yeu} eyep Ie[Nge] posmnbos oy) sopnyoul pue yuo] yodol oy) smoys xipusddy sy],
L00@-SZ0£-A.LS-FOd
DVAYOdT LAOdAA TWONNVIAAS ONV A TH.LNOW ~ € XIGNAddV
DOE-STD-3025-2007
CONCLUDING MATERIAL
Review Activity: Preparing Activity:
DOE-HS-30
HQ Offices Field Offices
NA Albuquerque Service Center
EE Chicago Operations Office
HS Idaho Operations Office Project Number:
EM Nevada Operations Office 4460-0009
ME Oakland Operations Office
NE Oak Ridge Operations Office
SC Office of River Protection
Richland Operations Office
National Laboratories
Brookhaven National Laboratory
Los Alamos National Laboratory
Lawrence Livermore National Laboratory
Oak Ridge National Laboratory
Sandia National Laboratory
Savannah River National Laboratory
20