DOE-STD-3025-99, Quality Assurance Inspection and Testing of HEPA Filters
Functional areas: Quality Assurance, Inspection, Testing, HEPA Filters
This standard establishes essential elements for the quality assurance inspection and testing of HEPA filters by U.S. Department of Energy (DOE)-accepted Filter Test Facilities (FTF). Superseded by DOE-STD-3025-2007.
Superseded By:
Version history and related documents
Superseded by
A newer version replaces this document.
Document text
Text extracted from the attached file. Refer to the original document for the authoritative version.
Section 1
TS
NOT MEASUREMENT
SENSITIVE
DOE-STD-3025-99
February 1999
Superseding
DOE NE F 3-43
February 1990
DOE STANDARD
QUALITY ASSURANCE INSPECTION AND
TESTING OF HEPA FILTERS
U.S. Department of Energy FSC 4460
Washington, D.C. 20585
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
This document has been reproduced from the best available copy.
Available to DOE and DOE contractors from ES&H Technical Information
Services, U.S. Department of Energy, (800) 473-4375, fax: (301) 903-9823.
Available to the public from the U.S. Department of Commerce, Technology
Administration, National Technical Information Service, Springfield, VA 22161;
(703) 605-6000.
DOE-STD-3025-99
iii
FOREWORD
This Department of Energy standard supercedes DOE NE F 3-43 and is approved for use by all DOE
components and their contractors.
This standard was developed primarily for application in U.S. Department of Energy programs. It contains
specific direction for HEPA filter testing performed at DOE-accepted HEPA Filter Test Facilities (FTFs).
Beneficial comments (recommendations, additions, deletions) and any pertinent data that may improve this
document should be sent to the Office of Nuclear Safety Policy and Standards (EH-31), U.S. Department of
Energy, Washington, D.C. 20585, by letter or by using the self-addressed Document Improvement Proposal
form (DOE F 1300.3) appearing at the end of this document.
DOE technical standards, such as this standard, do not establish requirements. However, all or part of the
provisions in a DOE standard can become requirements under the following circumstances:
(1) they are explicitly stated to be requirements in a DOE requirements documents; or
(2) the organization makes a commitment to meet a standard in a contract or in an implementation plan
or program plan required by a DOE requirements document.
Throughout this standard, the word "shall" is used to denote actions that must be performed if the objectives
of this standard are to be met. If the provisions in this standard are made requirements through one of the
two ways discussed above, then the "shall" statements would become requirements. It is not appropriate to
consider that "should" statements would automatically be converted to "shall" statements as this action would
violate the consensus process used to approve this standard.
NOTICE
The “Preparing Activity” wishes to establish continuity between this standard (DOE-STD-3025-99) and its
direct predecessor, entitled “DOE Filter Test Facilities Quality Program Plan (NE F 3-43)”. The original
standard was first issued by DOE as a Nuclear Energy (NE) standard on July 1986.
DOE-STD-3025-99
iv
INTENTIONALLY BLANK
DOE-STD-3025-99
v
TABLE OF CONTENTS
PARAGRAPH PAGE
1. SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Inclusions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. APPLICABLE DOCUMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.1 Department of Energy Standards and Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.2 Department of Defense Military (MIL) Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.3 National Consensus Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Section 2
3. DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1 Acceptance Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.2 Airflow Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.3 Count Geometric Mean Diameter (dg) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.4 Geometric Standard Deviation ( g) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.5 Di-Octyl Phthalate (DOP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.6 Di-Octyl Sebacate (DOS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.7 Filter Test Facility (FTF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.8 High Efficiency Particulate Air (HEPA) Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.9 High-Flow Alternative Test System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.10 Low-Flow Alternative Test System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.11 Nuclear Facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.12 Nominal Airflow Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.13 Operating Technician . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.14 Particle Collection Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.15 Penetration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.16 Penetrometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.17 Preparing Activity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.18 Standard Orifice Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.19 Test Aerosol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4. GENERAL PROVISIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5. PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6. RECEIPT OF FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.1 Receiving Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.2 Initial Handling and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.3 Pre-Test Filter Damage Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Section 3
7. PENETRATION AND RESISTANCE TESTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7.1 Testing Requirements and Test Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7.2 Test Aerosols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
8. INSPECTION AND TEST REPORTS, AND LABELING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
8.1 Inspection and Test Report for HEPA Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
8.2 Inspection and Test Report for Respirator Canisters . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
8.3 Labeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
DOE-STD-3025-99
vi
PARAGRAPH PAGE
9. PERSONNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
9.1 Qualification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
9.2 Physical Qualifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
9.3 Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
9.4 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
10. SEMIANNUAL REPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
10.1 Report Content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
10.2 Data Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
11. ACCURACY AND CONSISTENCY OF FTF MEASUREMENTS . . . . . . . . . . . . . . . . . . . . . 16
APPENDIX 1- QUALIFICATION OF NEW TEST METHODS AND EQUIPMENT . . . . . . . . . . . . . 17
1.1 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.2 PARTICLE SIZE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.3 RESISTANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.4 PENETRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.5 OTHER FACTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.6 APPROVAL OF PENETROMETER AND TEST PROCEDURES . . . . . . . . . . . . . . . 18
APPENDIX 2 - TEST AEROSOL CERTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.1 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.2 HEALTH AND SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.3 HAZARDOUS, TOXIC AND MIXED WASTE MANAGEMENT . . . . . . . . . . . . . . . 22
2.4 TEST AEROSOL CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
2.5 APPROVAL OF TEST AEROSOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Section 4
APPENDIX 3 - HEPA FILTER PENETRATION AND RESISTANCE TEST RESULTS . . . . . . . . . . 25
APPENDIX 4 - LABELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
APPENDIX 5 - SEMIANNUAL REPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
DOE-STD-3025-99
1
1. SCOPE
This standard establishes essential elements for the quality assurance inspection and testing of
HEPA filters by U.S. Department of Energy (DOE)-accepted Filter Test Facilities (FTF). The
standard specifies HEPA filter quality assurance inspection and testing practices established in
DOE-STD-3022-98, DOE HEPA Filter Test Program, and provides a basis for the preparation of
written operating procedures for primary FTF functions.
1.1 Applications
This standard applies only to the operations conducted at DOE-accepted Filter Test
Facilities.
1.2 Inclusions
This standard contains applicable protocols for inspecting and testing HEPA filters. It
identifies currently approved test aerosols and test methods. Appendices to the standard
provide specific procedures for acceptance of new test aerosols, and for calibration, test,
and qualification of alternate test methods.
2. APPLICABLE DOCUMENTS
The following documents are a part of this standard to the extent specified herein. Unless
otherwise stated, the current issue date and revision number of a referenced document shall
apply, including addenda and/or amendments. In the event of a conflict between provisions of
this standard and provisions of the referenced documents, the text of this standard shall take
precedence. Appeals in this matter may be addressed to the DOE "Preparing Activity," which is
designated as the DOE entity responsible for issue and interpretation of this standard.
2.1 Department of Energy Standards and Publications
DOE-STD-3020-97 - Specifications for HEPA Filters Used by DOE Contractors
DOE-STD-3022-98 - DOE HEPA Filter Test Program
DOE-STD-3026-99- Filter Test Facility Quality Program Plan (formerly DOE F NE 3-44)
ERDA 76-21 - Nuclear Air Cleaning Handbook
DOE-STD-3025-99
2
2.2 Department of Defense Military (MIL) Specifications
MIL-F-51079 - Filter, Medium, Fire Resistant, High Efficiency
2.3 National Consensus Standards
2.3.1 American Society of Mechanical Engineers (ASME)
ASME AG-1 Code, section FC - HEPA Filters
ASME 510-1980 - Testing of Nuclear Air-Cleaning Systems
2.3.2 Institute of Environmental Sciences, Mt. Prospect, Illinois
IES-RP-CC-001.3 - Recommended Practices for HEPA Filters
2.3.3 Underwriter Laboratories
UL 586 - Standard for High Efficiency, Particulate, Air Filter Units
3. DEFINITIONS
3.1 Acceptance Test
Inspection and testing of a nuclear grade filter to verify certain characteristics or
properties which determine acceptance or rejection of that filter.
3.2 Airflow Resistance
An index of the energy required to maintain airflow through a filter. Airflow resistance
is measured in terms of the air pressure difference (pressure drop) across a filter at a
specified flow rate (e.g. see section 5.2.2, Table-1, Standard DOE-STD-3020-97).
Note: The initial airflow resistance of a new filter serves as an index of the filter’s
potential loading capacity.
3.3 Count Geometric Mean Diameter (dg)
ln dg = 3 ni ln di
N
where ni = the number of particles in the ith size category,
Section 5
di = diameter of particles in the ith size category, and
N = 3 ni = the total number of particles.
DOE-STD-3025-99
1 Dennis, Richard, editor, "Handbook on Aerosols," US DOE/ERDA TID 26608, p. 111, 1976.
3
3.4 Geometric Standard Deviation ( g)
ln g = 3 ni (In di -In dg)
2 ½
ñ N - 1 �
3.5 Di-Octyl Phthalate (DOP)
Also known as di-ethylhexyl phthalate or DEHP. For purposes of this standard, an
aerosol of di-octyl phthalate droplets in clean filtered air.
3.6 Di-Octyl Sebacate (DOS)
Also known as di-ethylhexyl sebacate or DEHS. For purposes of this standard an aerosol
of di-octyl sebacate droplets in clean filtered air1.
3.7 Filter Test Facility (FTF)
A facility accepted by the DOE specifically to conduct quality assurance inspections and
tests of HEPA filters.
3.8 High Efficiency Particulate Air (HEPA) Filter
A throwaway, extended-media, dry type filter with a rigid casing enclosing the full
depths of the pleats. Aerosol collection efficiency of the filter shall be at least 99.97%
for 0.3 micrometer diameter particles. The maximum airflow resistance shall be as
specified in Section 5.2.2, Table 1 of DOE-STD-3020-97.
3.9 High-Flow Alternative Test System
A method of testing HEPA filters rated at greater than 250 cubic feet per minute (cfm)
that consists of a laser aerosol spectrometer, a microcomputer, an aerosol diluter and a
Laskin nozzle system to generate test aerosol. Penetration is determined at discrete
aerosol particle sizes in the range where maximum penetration occurs.
DOE-STD-3025-99
4
3.10 Low-Flow Alternative Test System
A test method to evaluate penetration characteristics of HEPA filters with design air flow
rates of 250 cfm or less. The measurement technique is the same as that for the High-
Flow Alternative Test System.
3.11 Nuclear Facility
Nuclear Facility - Nuclear facility means reactor and nonreactor nuclear facilities. This
definition is taken from 10 CFR 830, Nuclear Safety Management, Section 830.3,
Definitions. "Nonreactor nuclear facility" as well as "reactor" are defined in detail in
this section of the Code of Federal Regulations.
3.12 Nominal Airflow Rating
The flow rate at which HEPA filters are identified by the manufacturer and confirmed by
the FTF. Nominal airflow ratings for various size filters are listed in DOE-STD-3020-97
(Section 5.2.2, Table 1).
3.13 Operating Technician
An individual who has been trained and qualified in accordance with Section 9 of this
standard to inspect and test HEPA filters.
3.14 Particle Collection Efficiency
For FTF activities, the measure of filter effectiveness, expressed as a percent, determined
from the equation:
E = 100 - P
where P = percent penetration
3.15 Penetration
The downstream test aerosol concentration, expressed as a percentage of the upstream
test aerosol concentration.
DOE-STD-3025-99
5
3.16 Penetrometer
A machine for determining test aerosol penetration and airflow resistance of HEPA
filters which incorporates an approved aerosol and aerosol generator, a penetration
meter, manometers for measuring resistance to airflow, a flow meter for determining test
airflow, and a chuck assembly for encapsulating and holding the filter under test.
3.17 Preparing Activity
The DOE organization responsible for issue and interpretation of this standard.
3.18 Standard Orifice Plate
A secondary standard for measuring airflow through the Penetrometer. Orifice plates
Section 6
shall be calibrated using a National Institute of Standards Technology (NIST) traceable
standard as a primary standard.
3.19 Test Aerosol
The aerosol produced from a substance approved by DOE for testing HEPA filters.
4. GENERAL PROVISIONS
Each HEPA filter procured for installation in a DOE nuclear facility shall be submitted for
testing at a Filter Test Facility (FTF). The tests are performed in accordance with section 5 of
this standard, the customer’s written specifications or procurement documents, and any special
written instructions from the customer. Unless otherwise instructed, FTF tests and inspections
shall include:
C Visual inspection for compliance with purchase order, e.g., type, size, quantity received,
shipping damage, and Qualification Certification.
C Visual inspection for manufacturing defects and compliance with construction and
materials requirements.
C Penetration at 100% (all filters) and penetration at 20% (size 3 and higher) of nominal
airflow rating.
C Airflow resistance at 100% of test airflow.
DOE-STD-3025-99
6
C Verification that the filter make and model is approved by DOE.
Maximum penetration allowed is 0.03% (0.0003) at an aerosol particle diameter of 0.3
micrometers. If a higher penetration is measured, the filter shall be rejected and the customer
notified that the filter does not meet the penetration requirement. When tested with a DOE-
approved laser spectrometer test method, the maximum penetration and the aerosol particle size
of maximum penetration shall be reported in addition to the penetration at 0.3 micrometers
diameter. However, penetration at 0.3 micrometers diameter shall be the only criterion used to
judge whether a filter is rejected for excess penetration.
Maximum airflow resistance (see Section 5.2.2, Table 1 of DOE-STD-3020-97) is 1.0 inches of
water gage (in. H2O) (250 Pa) across the filter pack for size 4 (nominal 500 cfm) through size 6
(nominal 1250 cfm) filters, and 1.3 in.H2O (325 Pa) for filters size 1 (nominal 25 cfm) through
size 3 (nominal 125 cfm) and filters size 7 (nominal 1500 cfm) and size 8 (nominal 2000 cfm).
The resistance shall be reported to the nearest 0.1 in. H2O (25 Pa). There shall be no waivers
from penetration or resistance requirements, nor shall defects in the filter media be repaired at
the FTF. It is the responsibility of the purchaser and the manufacturer to determine proper
disposition of non-conforming filters.
5. PROCEDURES
All FTF operations shall be conducted in accordance with written procedures that address the
subjects and inform to this standard. All procedures shall contain specific acceptance criteria.
Each FTF shall prepare, maintain, and operate in accordance with detailed procedures which
cover, as a minimum, the following functions:
C Receiving inspection.
C Un-boxing, handling, re-boxing, and storage of filters.
C Inspection for defects, damage, and compliance with purchase order
specifications.
C Verification of compliance with qualifications test requirements, e.g., over-
pressure resistance, fire and heated air test, and resistance to rough handling
(QPL listing).
C Documentation and records keeping.
DOE-STD-3025-99
7
C Operating and calibration procedures for each penetration and resistance test
device.
C Test and inspection reports, including disposition and retention.
C Labeling of accepted and rejected filters.
C Segregation and disposition of rejected filters.
Section 7
C Shipping of accepted filters.
C Preparation of semiannual reports to DOE.
C Training and qualification of personnel.
C Surveys or precautions taken for protection of health, safety, and the
environment.
6. RECEIPT OF FILTERS
6.1 Receiving Inspection
All filter packages shall be inspected upon receipt at the FTF. Damaged cartons or
cartons improperly oriented shall be opened immediately and the filters inspected. A
description of observed damage shall be recorded in the filter inspection and test report.
6.2 Initial Handling and Storage
Filter handlers shall be properly trained to handle filter boxes carefully. Cartons shall be
oriented with arrows on the filter cartons pointed "up". Filter cartons shall be stacked
not more than three (3) high, and stored in a clean, dry location. Unless otherwise
required, storage facilities for HEPA filters shall be equipped with temperature and
humidity controls.
6.3 Pre-Test Filter Damage Inspection
Prior to testing, each filter shall be visually examined for possible damage, compliance
with purchaser’s specifications, and workmanship. Damage to filters noted during the
pre-test inspection shall be recorded on the filter inspection and test report. Filters
obviously damaged shall not be further tested, but shall be immediately rejected.
DOE-STD-3025-99
8
The damage inspection shall, as a minimum, include: verification of general
workmanship, filter type, size, gasket installation and material, separators, frame
dimension, squareness, face guards, and required labels or markings. Filters shall be
inspected for looseness of filter packs, excessive slump or distortion, loose gaskets,
breaks or tears, or patching of the filter medium.
7. PENETRATION AND RESISTANCE TESTING
7.1 Testing Requirements and Test Methods
Following visual inspection, each filter, completely encapsulated in the test apparatus,
shall be tested for penetration at 100% of the nominal air flow rating, and filters rated at
125 cfm (0.059 m3/s) or greater shall also be tested at 20% of the nominal airflow rating.
Each filter shall be tested for resistance to airflow at 100% of the nominal airflow rating.
Test air flow rates shall be measured in actual cubic feet per minute (acfm), not standard
cubic feet per minute. The filter test apparatus shall be equipped with "chucks" which
encapsulate the HEPA filter in the test position. Self contained (nipple ended) filters
shall not be routinely tested for resistance to airflow. Operating and test procedures shall
be prepared for each test device and shall include, as a minimum, the following elements:
C Filling the generator reservoir and verification of fluid level.
C Daily verification of airflow rates using NIST traceable orifice plates. Flow
rates shall be adjusted to within + 2% of the orifice plate calibration value.
C Adjustment and verification of critical airflows (and temperatures for thermal
test method only).
C Calibration of filter test equipment which determines particle size, penetration,
and resistance. Calibration of instruments which are used to calibrate the filter
test equipment.
C Calibration schedules.
C Design and use of adapters to permit tests of non-standard filters or special test
procedures.
C Operating and calibration procedures.
C Operation, service, and maintenance of test equipment, including the system
exhaust air cleaning device.
DOE-STD-3025-99
9
For penetration and resistance testing, two Penetrometer systems have long been
Section 8
authorized. Both Penetrometer systems operate using "hot" aerosol. They are:
C The Q-107 for testing filters with rated airflows of 250 cfm (0.12 m3/s) and
above.
C The Q-76 for testing filters with rated airflows below 250 cfm (0.12 m3/s).
Currently, a laser spectrometer analyzer system, the High Flow Alternative Test System
(HFATS), operating with "cold" aerosol, is the method of choice for testing filters with
rated airflows of >250 cfm. It is used in conjunction with the Q-107 system. Provisions
for qualifying new test methods appear in Appendix 1 to this standard.
7.2 Test Aerosols
Test aerosol materials, currently approved by DOE for FTF testing are Di-octyl Phthalate
(DOP) and Di-octyl Sebacate (DOS). Provisions for qualifying new test aerosols appear
in Appendix 2 to this standard.
8. INSPECTION AND TEST REPORTS, AND LABELING
8.1 Inspection and Test Report for HEPA Filters
A report or data sheet (see Appendix 3) shall be prepared for each customer order. The
report shall include as a minimum:
C Identification of the FTF.
C Name of customer.
C Customer order number(s).
C Date of shipment receipt at FTF.
C Date of inspection and test.
C Customer’s specification or standard (if applicable).
C Filter manufacturer.
DOE-STD-3025-99
10
C Filter description (model or designation number).
C Nominal airflow rating.
C Test flow air temperature.
C Ambient relative humidity in room at time of test.
C Barometric pressure at time of test.
C Name of operating technician and supervisor responsible for test.
C Serial number of each filter tested.
C Resistance (in. wg or Pa) across filter pack at nominal airflow rating.
C Penetration at nominal airflow rating.
C Penetration at 20% of rated airflow [filters 125 cfm (0.059m3/s) and above].
C Remarks: Reason for rejection.
P = penetration
R = resistance
O = other: describe briefly
When tests are conducted with the HFATS, the maximum penetration and the aerosol particle
size of maximum penetration shall be reported in addition to the penetration at 0.3 micrometers
diameter. However, penetration at 0.3 micrometers diameter shall be the only criterion used to
judge whether a filter is rejected for excess penetration.
Penetration results shall be reported to the nearest .01%. the maximum penetration and the
aerosol particle size of maximum penetration shall be reported in addition to the penetration at
0.3 micrometers diameter. However, penetration at 0.3 micrometers diameter shall be the only
criterion used to judge whether a filter is rejected for excess penetration. For example, a reading
of 0.023% shall be reported as 0.02%; a reading of 0.026% shall be reported as 0.03%.
DOE-STD-3025-99
11
8.2 Inspection and Test Report for Respirator Canisters
When respirator canisters are tested at FTFs, a data report shall be prepared for each
customer order or shipment which shall include the following as a minimum:
C Name of customer.
C Customer order number.
C Date of receipt.
C Date of inspection and test.
C Customer’s specification.
C Manufacturer’s name and designation.
C Number of respirator canisters in shipment.
C Number of canisters accepted.
C Number of canisters rejected.
C Remarks.
C Authorized signature.
8.3 Labeling
8.3.1 Accepted Filters. Each accepted HEPA filter shall be identified with a
permanent "Accepted" label (yellow). A suggested "Accepted" label design is
shown in Appendix 4, and includes the following:
Section 9
C Identification of FTF.
C Penetration at nominal airflow rating.
C Resistance at nominal airflow rating.
DOE-STD-3025-99
12
C Penetration at 20% of nominal airflow rating [filters 125 cfm
(0.059m3/s) and larger].
8.3.2 Rejected Filters. Each rejected HEPA filter shall be identified with a
permanent "Rejected" label (red). A suggested "Rejected" label design is
shown in Appendix 4.
8.3.3 Accepted Respirator Canisters. As a minimum, accepted respirator canisters
shall be dated. The date shall be applied with a marking pen or by means of a
label.
8.3.4 Rejected Respirator Canisters. Rejected canisters shall be marked, or
physically deformed and segregated to prevent commingling with accepted
canisters.
9. PERSONNEL
All personnel who inspect, test, supervise, or interpret the results of inspections and tests of
HEPA filters at the FTFs shall be qualified in accordance with section 9.1 of this standard. Non-
FTF personnel who handle HEPA filters or canisters, including shipping, receiving, and
materials-handling personnel shall, as a minimum, be instructed in the requirements for proper
handling, stacking, and storage of HEPA filters. Precautions and recommendations to be
observed in the handling and storage of HEPA filters are given in section 9.1.1 of this standard
and in Appendix C of the "Nuclear Air Cleaning Handbook" (ERDA 76-21).
9.1 Qualification
The FTF operating contractor shall ensure that personnel selected to conduct, supervise,
or interpret the results of FTF inspections and tests are qualified by experience, formal
training or instruction, and are physically capable of carrying out the functions for which
they are responsible.
9.1.1 Materials Handling. Personnel assigned to handle the HEPA filters shall be
instructed in the proper procedures for:
C Handling, stacking, storing, un-boxing, re-boxing, crating, and placing
filters on pallets.
C Operation of appropriate materials handling equipment, such as fork-lift
industrial trucks, hoists, or conveyers.
DOE-STD-3025-99
13
C Verifying compliance with qualification requirements by review of
records.
C Inspection for shipping damage at time of receipt.
C Preparing of filters for shipping, including the proper loading in
transport vehicles.
9.1.2 Inspection and Testing. Personnel responsible for inspection and testing of
HEPA filters, for the supervision of inspection and testing, or for the
interpretation of inspection and test results shall have had formal training and
demonstrated performance or comprehension in the following:
C All applicable provisions of this standard.
C Applicable specifications for HEPA Filters used at DOE nuclear
facilities.
C Materials, construction and performance specifications of HEPA filters.
C Use and interpretation of filter specifications and customer purchase
criteria, with particular attention to ASME AG-1 Code, Section FC
(formerly Military Specifications MIL-F-51068), MIL-F-51079, and
Institute of Environmental Sciences publication IES-RP-CC-001.3.
C Performance specifications for test devices and other instruments used at
the FTF.
C Procedures for handling, inspection, testing data, recording, labeling,
and disposition of accepted and rejected filters.
C Proficiency in the operation, adjustment, and maintenance FTF
instruments and equipment.
9.1.3 Certification of Test Results. Personnel responsible for interpretation or
certification of inspection and test results shall, in addition to the requirements
Section 10
of section 9.1.2 of this standard, have demonstrated proficiency in the
following:
C Data evaluation and analysis, including validation of test results.
DOE-STD-3025-99
14
C Interpretation of applicable standards, specifications, and customer
purchase-order requirements relative to the acceptability of filters.
C Determination of the appropriate rejection status when compliance with
all specified requirements cannot be demonstrated.
C Preparation and issuance of appropriate documentation of inspection and
test results.
C Assessment of manufacturer’s materials of construction and
certifications, and compliance of filters to such certifications.
C Personnel in this category have the authority to sign data forms and
reports attesting to the accuracy and completeness of the reported data or
results.
9.2 Physical Qualifications
Personnel responsible for supervision of inspection and testing activities or for
interpretation of inspection and test results shall meet appropriate physical qualifications
as evidenced by satisfactory completion of physical examination. The physical
examination shall be performed by a qualified industrial physician, and shall include the
following:
C Visual acuity, including near vision, depth perception, and color
discrimination.
C Physical capability for performing job related tasks.
C Hearing acuity.
9.3 Training
Personnel responsible for HEPA filter inspection and testing, for supervision of
inspection and testing, or for interpretation of inspection and test results, shall
satisfactorily complete a formal training course. This course shall address the principles
of HEPA filter testing. The course shall be equivalent to the Harvard University School
of Public Health In-Place Filter Testing Workshop. New hires shall receive on-the-job
training and instruction by qualified personnel to become completely familiar with the
equipment, instrumentation, and procedures. FTF management is responsible for
DOE-STD-3025-99
15
establishing ongoing personnel maintenance and re-certification programs that assure
personnel remain qualified to carry-out required FTF activities.
9.4 Documentation
Physical and technical qualifications of personnel responsible for inspection and testing,
supervision of inspection and testing, and interpretation of inspection and test results,
shall be documented. Documentation shall include written evidence of the dates and
extent of instruction and formal training, and shall be signed by a responsible supervisor.
The supervisor’s signature will certify satisfactory demonstration of the individual's
ability to perform all job functions.
9.4.1 Retention of Records. Personnel records shall be retained for the duration of
the individual's assignment to the FTF, and shall be subject to audit and re-
certification by demonstration as specified by facility procedures. Re-
certification will be required at intervals to be defined in facility operating
procedures
10. SEMIANNUAL REPORT
At the end of each fiscal year (September 30) and half fiscal year (March 31), each FTF shall
prepare a report describing test activities for the previous 6-month period, including a tabulation
of test data as described below. Copies shall be sent only to the Technical Support Contractor
and to DOE. Further distribution of HEPA filter test data shall be at the discretion of DOE.
10.1 Report Content
The content of the semiannual report shall meet the requirements specified in section
Section 11
10.2 of this standard. Narrative information, including explanations of trends or
problems observed during the report period, shall be provided.
10.2 Data Summary
A summary of HEPA filter test data during the report period shall be presented in table
form. As a minimum the tabulation shall provide the following data for each HEPA
filter tested:
C Name of purchaser and manufacturer.
C Nominal airflow rating in cfm.
DOE-STD-3025-99
16
C Number of each size received and tested.
C Number of filters accepted.
C Number of filters rejected.
C Reason for rejection [penetration, resistance, other (explain)].
C A sample form for the semiannual report appears in Appendix 5.
11. ACCURACY AND CONSISTENCY OF FTF MEASUREMENTS
Consolidation of DOE filter testing at one FTF makes it necessary that a new metric be
developed for measuring accuracy and consistency of FTF measurements. A new method is
being developed in coordination with DOE, the FTF, and the Technical Support Group. The
modified procedure will be incorporated in this standard through a Change Notice.
DOE-STD-3025-99
17
APPENDIX 1- QUALIFICATION OF NEW TEST METHODS AND EQUIPMENT
1.1 SPECIFICATIONS
Only test equipment and measurement techniques approved by the DOE shall be used for quality
assurance testing of HEPA filters at the FTFs. DOE approval shall be contingent on satisfactory
completion of the following specifications.
1.2 PARTICLE SIZE
1.2.1 Particle Size Range
The new instrument and/or test technique shall be capable of determining aerosol
penetration in the particle diameter ranged from 0.1 micrometers to greater than 0.3
micrometers in discrete measurable particle size ranges no larger than 0.05 Fm.
Particle size measurements shall have a precision and accuracy of ±10%.
1.3 RESISTANCE
1.3.1 Measurement Capability
The new instrument and/or test technique shall be capable of measuring airflow
resistance within an accuracy and precision of ±5% of a filter under test at its nominal
airflow rating.
1.3.2 Calibration
Pressure and temperature measuring instruments, orifice plates, mass-flow meters and
other instruments critical to performance of the proposed test technique shall be
calibrated by the use of standards traceable to recognizable NIST standards.
1.4 PENETRATION
1.4.1 Penetration Measurement
The test method shall be capable of determining penetration up to 0.03% +0.005% in
the particle diameter range from 0.1 Fm to 0.2 Fm. Aerosol dilution will be permitted
only after demonstration that the overall test efficiency and reliability have not been
adversely affected, nor have the dilution techniques adversely affected particle size or
concentration.
DOE-STD-3025-99
18
1.4.2 Generator Capacity
The generator shall produce an aerosol quantity sufficient for reliable determination of
minimum filter penetration of 0.005%.
1.4.3 Test Aerosol Concentrations
Test aerosol concentrations shall meet the requirements of Appendix 2.4.1.
1.4.4 Test Flow Rates
The measurement and testing techniques shall be capable of testing HEPA filters at
nominal airflow rating
1.5 OTHER FACTORS
1.5.1 Maintainability and Operability
The test equipment shall be readily operable by trained technicians. Components that
require repair or realignment by skilled personnel should be of a modular design such
that they can be replaced by the trained technician.
1.5.2 Aerosol Sampling
Upstream and downstream concentrations measured by the new test equipment shall be
Section 12
demonstrated to be representative of the respective total concentrations within ±5%.
Establishment of representativeness can be achieved by multiple sampling (across the
area of the downstream face of a filter and across the cross-section of the chuck,
upstream of the filter under test), using an averaging procedure described in ANSI
N510-1980 or by using an alternate procedure approved by the DOE.
1.6 APPROVAL OF PENETROMETER AND TEST PROCEDURES
1.6.1 Notice of Intent
Organizations desiring to receive DOE approval of a penetrometer or test procedure for
quality assurance testing of HEPA filters shall notify the DOE FTF Coordinator in
writing and shall provide preliminary data which demonstrates how the specifications
DOE-STD-3025-99
19
of A5.5 will be met and provides plans for further tests and analyses that are deemed
necessary.
1.6.2 Approval
1. The application for DOE approval will be sent to the Technical Review Committee
for review and comment. Consensus (majority) approval by the Technical Review
Committee will be solicited.
2. Following resolution of comments from the Technical Review Committee, the
DOE "Preparing Activity" will be petitioned for approval of the penetrometer or
test procedure.
DOE-STD-3025-99
20
INTENTIONALLY BLANK
DOE-STD-3025-99
21
APPENDIX 2 - TEST AEROSOL CERTIFICATION
2.1 SPECIFICATIONS
Substances used as test aerosols for quality assurance testing at FTFs shall be DOE approved
(see 2.5.).
2.2 HEALTH AND SAFETY
2.2.1 Toxicity
Studies shall be performed or validated to show that use of test aerosols present no
unacceptable occupational risk when used to perform the tests specified herein. The
studies must consider the expected exposure pathways (skin absorption, inhalation)
and the fate of the inhaled material in terms of material transfer, residence times,
critical organs, and results.
Toxicity assessments should consider quantities and concentrations of
materials and exposure pathways which approximate realistic occupational or
accidental exposure.
2.2.1.1 Engineering Design as Alternative to Toxicity Testing. When toxicity
testing has not been performed, or toxicity test results are inconclusive,
candidate test aerosols can be used in FTFs if compliance with the following
requirements has been demonstrated.
C Engineering design and construction is adequate to prevent test aerosols
from contaminating breathing air in the FTF (aerosol confinement).
C Engineering design and construction of exhaust air handling systems is
adequate to minimize quantities of test aerosols released to the
surrounding environment.
C Applicable exposure limits (concentration guidelines) are established as
maximum concentrations for breathing air within the FTFs and for
exhaust air from exhaust stacks.
C Air sampling or monitoring programs are adequate to determine
compliance with the above exposure limits.
DOE-STD-3025-99
22
2.2.2 Fire and Explosion Safety
Proposed test substances including their aerosol forms shall be analyzed and/or tested
to determine that their use under normal testing conditions will present no
unacceptable risks due to fire or explosion.
2.3 HAZARDOUS, TOXIC AND MIXED WASTE MANAGEMENT
HEPA filter test aerosols shall be selected to avoid generation of EPA regulated wastes by
contamination of filters during test activities. Substances known to result in generation of
Hazardous Wastes regulated by the Resources Conservation and Recovery Act (RCRA), or Toxic
Section 13
Wastes regulated by the Toxic Substances Control Act (TSCA), shall not be acceptable
candidates for HEPA filter test aerosols.
2.4 TEST AEROSOL CHARACTERISTICS
2.4.1 Mandatory Requirements
The test agent shall produce an aerosol with the following characteristics as measured
by an approved Penetrometer:
The aerosol shall have a size distribution and concentration sufficient to permit precise
(see A5.4.1) penetration determinations in the size range from 0.1 Fm to >0.3 Fm
using an approved aerosol measurement device. The aerosol shall be composed of
spherical particles.
The aerosol material shall have a density less than 2 g/cm3.
2.5 APPROVAL OF TEST AEROSOLS
2.5.1 Notice of Intent
1. Persons or organizations desiring to qualify a new test aerosol for DOE HEPA
filter test activities shall first notify the DOE FTF Coordinator or the Technical
Support Group. If requested, the FTF Coordinator will assist in preparing the
required petition for submittal to DOE.
2. The petition shall include preliminary data to demonstrate compliance with
subparts 2.2, 2.3 and 2.4. Preliminary evidence of compliance may be
demonstrated by literature review, Material Safety Data Sheets (MSDS), test and
DOE-STD-3025-99
23
analysis, or discussion of further analysis and testing which the petitioner feels is
necessary.
2.5.2 Approval of Proposed Test Aerosols
1. The petition for DOE approval will be sent through the DOE FTF Coordinator to
the Technical Review Committee for review, comment and recommendation. The
committee consists of persons representing government, universities and industry.
Consensus (majority) approval by the Technical Review Committee will be
solicited.
2. Application for final DOE approval shall be accompanied by all supporting test
data and evaluations conducted for that test aerosol.
3. Resolution of comments and receipt of consensus agreement from the Technical
Review Committee is necessary for DOE approval.
4. Following resolution of comments from the Technical Review Committee, the
DOE "Preparing Activity" will be petitioned for approval of the proposed test
aerosol.
DOE-STD-3025-99
24
INTENTIONALLY BLANK
DOE-STD-3025-99
25
APPENDIX 3 - HEPA FILTER PENETRATION AND RESISTANCE TEST RESULTS
FTF Name
FTF Address
INSPECTION AND TEST REPORT
MANUFACTURE P.O.
NO.
DATE
REC.
DATE
TESTED
NO.
FILTERS
FILTER
MODEL
SIZE-CFMTEMP.HUM.TESTED BY
FILTER
SERIAL NO. OK NG
RES. IN
W.G.
DOP PENETRATION % REMARKS
100% 20%
We certify that the filters listed by identifying number have been tested and inspected and that the above readings are
true and correct.
DOE-STD-3025-99
26
HEPA FILTER VISUAL INSPECTION
FILTER PRE-TEST POST-TEST
SERIAL
NO.
SAT UNSAT SAT UNSAT COMMENTS
Performed By: /
Filter Test Technician Date
Reviewed By: /
FTF Supervisor Date
DOE-STD-3025-99
27
APPENDIX 4 - LABELS
DOE-STD-3025-99
28
DOE-STD-3025-99
29
APPENDIX 5 - SEMIANNUAL REPORT
This Appendix shows a suggested report format that includes the required tabular data that will simplify
extracting data for analysis. Other aspects of the semiannual report, including any narrative, may be
provided at the discretion of the individual FTF.
DOE-STD-3025-99
30
HEPA Filter Data Summary
Customer
or
Purchaser
(a)
Manufacturer
and Model
Rated
Capacit
y
(cfm)
Number
Received
Number
Initially
Accepted
Number
Rejected
(b)
a. Place “D” after name if it is a DOE contractor that is not billed for service
Section 14
b. Symbols for Rejections:
P excessive penetration NS noncompliance with specification
R excessive resistance F damaged frame
L label LP loose package or sagging media
M media damage OT other
G loose or damaged gasket
CD carrier damage
DOE-STD-3025-99
CONCLUDING MATERIAL
Review Activity: Preparing Activity:
DOE-DP-45
DOE Field Offices
DP-21/23/25/31/33 AL
EH-11/30/63 CH Project Number:
EM-23 ID 4460-0003
NE-44 NV
ER-8.1 OR
SR
RF
National Laboratories
INEL
Area Offices
Amarillo Area Office
Kirtland Area Office
COVER
FOREWORD
TABLE OF CONTENTS
1. SCOPE
1.1 Applications
1.2 Inclusions
2. APPLICABLE DOCUMENTS
2.1 Department of Energy Standards and Publications
2.2 Department of Defense Military (MIL) Specifications
2.3 National Consensus Standards
3. DEFINITIONS
3.1 Acceptance Test
3.2 Airflow Resistance
3.3 Count Geometric Mean Diameter (dg)
3.4 Geometric Standard Deviation
3.5 Di-Octyl Phthalate (DOP)
3.6 Di-Octyl Sebacate (DOS)
3.7 Filter Test Facility (FTF)
3.8 High Efficiency Particulate Air (HEPA) Filter
3.9 High-Flow Alternative Test System
3.10 Low-Flow Alternative Test System
3.11 Nuclear Facility
3.12 Nominal Airflow Rating
3.13 Operating Technician
3.14 Particle Collection Efficiency
3.15 Penetration
3.16 Penetrometer
3.17 Preparing Activity
3.18 Standard Orifice Plate
3.19 Test Aerosol
4. GENERAL PROVISIONS
5. PROCEDURES
6. RECEIPT OF FILTERS
6.1 Receiving Inspection
6.2 Initial Handling and Storage
6.3 Pre-Test Filter Damage Inspection
7. PENETRATION AND RESISTANCE TESTING
7.1 Testing Requirements and Test Methods
7.2 Test Aerosols
8. INSPECTION AND TEST REPORTS, AND LABELING
8.1 Inspection and Test Report for HEPA Filters
8.2 Inspection and Test Report for Respirator Canisters
8.3 Labeling
9. PERSONNEL
9.1 Qualification
9.2 Physical Qualifications
9.3 Training
9.4 Documentation
10. SEMIANNUAL REPORT
10.1 Report Content
10.2 Data Summary
11. ACCURACY AND CONSISTENCY OF FTF MEASUREMENTS
APPENDIX 1
APPENDIX 2
APPENDIX 3
APPENDIX 4
APPENDIX 5
CONCLUDING MATERIAL