DOE-STD-1063-2006, Facility Representative
Functional areas: Facility Representative, Price Anderson
The purpose of the DOE Facility Representative Program is to ensure that competent DOE staff personnel are assigned to oversee the day to day contractor operations at DOE's hazardous nuclear and non-nuclear facilities.
Unknown Block text
Supersedes:
DOE-STD-1063-2000, Facility Representatives on Apr 04, 2006
Superseded By:
DOE-STD-1063-2011, Facility Representatives on Mar 01, 2011
Version history and related documents
Superseded by
A newer version replaces this document.
- DOE-STD-1063-2011Facility Representatives (Mar 01, 2011)
Supersedes
Earlier documents this one replaced.
- DOE-STD-1063-2000Facility Representatives (Apr 04, 2006)
Document text
Text extracted from the attached file. Refer to the original document for the authoritative version.
Section 1
TS
DOE-STD-1063-2006
April 2006
Superseding
DOE-STD-1063-2000
March 2000
DOE STANDARD
FACILITY REPRESENTATIVES
U.S. Department of Energy AREA MGMT
Washington, D.C. 20585
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
NOT MEASUREMENT
SENSITIVE
DOE-STD-1063-2006
ii
Available on the Department of Energy
Technical Standards Program web site at
http://www.eh.doe.gov/techstds/
DOE-STD-1063-2006
iii
FOREWORD
1. This Department of Energy standard is approved for use by all DOE Components.
2. The revision to this DOE standard was developed by a working group consisting of
headquarters and field participants. Beneficial comments (recommendations,
additions, deletions) and any pertinent data that may improve this document should
be sent to:
John D. Evans
Facility Representative Program Manager
Office of the Departmental Representative to the Defense Nuclear Facilities
Safety Board (DOE DR-1)
DOE Headquarters, Forrestal Building
1000 Independence Avenue, SW
Washington, D.C. 20585
(202) 586-3887
Additional information on the DOE Facility Representative Program is available
on the DOE Facility Representative web site at http://www.facrep.org/.
Comments regarding this standard or the DOE Facility Representative Program
can be submitted electronically from the web site.
3. DOE technical standards, such as this standard, do not establish requirements.
However, all or part of the provisions in a DOE standard can become requirements
if they are explicitly stated to be requirements in a DOE requirements document, or
the organization makes a commitment to meet a standard in a contract or in an
implementation plan or program plan required by a DOE requirements document.
4. Throughout this standard, the word "shall" is used to denote actions that must be
performed if the objectives of this standard are to be met. If the provisions in this
standard are made requirements through one of the two ways discussed above,
then the "shall" statements would become requirements. It is not appropriate to
consider that any "should" statements would automatically be converted to "shall"
statements, as this action would violate the consensus process used to approve
this standard.
DOE-STD-1063-2006
iv
INTENTIONALLY BLANK
DOE-STD-1063-2006
v
CONTENTS
PAGE
1. SCOPE .................................................................................................................. 1
1.1 Scope ..................................................................................................................... 1
1.2 Purpose of Program............................................................................................. 1
1.3 Purpose of Standard ............................................................................................ 1
1.4 Applicability .......................................................................................................... 1
2. REFERENCES .................................................................................................... 3
2.1 Government Documents .................................................................................... 3
2.1.1 DOE Directives (Polices, Orders, Manuals, Guides) ....................... 3
2.1.2 DOE Standards ....................................................................................... 3
2.1.3 Other ......................................................................................................... 4
2.2 Order of Precedence .......................................................................................... 4
Section 2
3. DEFINITIONS ...................................................................................................... 5
4. DUTIES, RESPONSIBILITIES, AND AUTHORITIES OF
FACILITY REPRESENTATIVES AND OTHER KEY PERSONNEL .......... 9
4.1 Duties, Responsibilities, and Authorities of Facility Representatives .......... 9
4.1.1 Operational Awareness.......................................................................... 9
4.1.2 Communication ....................................................................................... 9
4.1.3 Availability ................................................................................................ 9
4.1.4 Independence.......................................................................................... 9
4.1.5 Scope of Reviews .................................................................................10
4.1.6 Routine Activities...................................................................................10
4.1.7 Stop Work Authority..............................................................................10
4.1.8 Relationship of Facility Representative with DOE Managers ........11
4.1.9 Relationship of Facility Representatives with Other DOE
Oversight Personnel.............................................................................11
4.1.10 Relationship of Facility Representatives with Operating
Contractor ..............................................................................................11
4.2 Duties, Responsibilities, and Authorities of Other Key Personnel..............13
4.2.1 Deputy Secretary ..................................................................................13
4.2.2 Facility Representative Program Manager .......................................14
4.2.3 Cognizant Secretarial Officers ............................................................14
4.2.4 Field Element Managers ......................................................................14
4.2.5 Facility Representative Program Sponsors ......................................15
DOE-STD-1063-2006
vi
5. FACILITY REPRESENTATIVE PROGRAM REQUIREMENTS................16
5.1 Facility Coverage and Staffing .........................................................................16
5.2 Facility Assessment Plans and Reports .........................................................17
5.3 Unencumbered Access .....................................................................................18
5.4 Training ................................................................................................................19
5.4.1 Needs Analysis......................................................................................19
5.4.2 Formal Training .....................................................................................19
5.4.3 On-the-Job Training..............................................................................19
5.4.4 Continuing Training ...............................................................................19
5.5 Qualification.........................................................................................................19
5.5.1 Qualification Card .................................................................................20
5.5.2 Core Qualification .................................................................................21
5.5.3 Interim Qualification..............................................................................21
5.5.4 Full Qualification....................................................................................21
5.5.5 Qualification on Additional Facilities After Full Qualification ..........21
5.5.6 Requalification .......................................................................................21
5.5.7 Proficiency..............................................................................................22
5.5.8 Examinations .........................................................................................22
5.6 Designated Facility Representative .................................................................24
5.7 Recruitment, Selection, Retention, and Advancement Considerations .....24
5.7.1 Recruitment and Selection ..................................................................26
5.7.2 Retention and Advancement ...............................................................27
5.8 Facility Representative Program Performance Assessment
Section 3
and Feedback .....................................................................................................27
5.8.1 Performance Indicators ........................................................................27
5.8.2 Field Element Self-Assessments........................................................28
5.8.3 Peer Reviews.........................................................................................28
5.8.4 Annual Facility Representative Workshop ........................................28
5.8.5 Communication and Feedback Mechanisms ...................................29
5.9 Differing Professional Opinions ........................................................................29
TABLE
Table 1 – Facility Representative Qualification.........................................................25
APPENDICES
Appendix A Facility Representative Performance Indicators ............................... A-1
Appendix B Facility Representative Program Assessment Guide ...................... B-1
Appendix C Process to Determine Facility Representative Staffing ...................C-1
Appendix D Continuing Training Guidance.............................................................D-1
DOE-STD-1063-2006
1
1. SCOPE
1.1 Scope. This standard, DOE-STD-1063-2006, FACILITY
REPRESENTATIVES, defines the duties, responsibilities and
qualifications for DOE Facility Representatives, based on facility hazard
classification; risks to workers, the public, and the environment; and the
operational activity level. This standard provides the guidance necessary
to ensure that DOE’s hazardous nuclear and non-nuclear facilities have
sufficient staffing of technically-qualified Facility Representatives to
provide day-to-day oversight of contractor operations. Field Element
Managers should incorporate the information contained in this standard,
as well as any additional facility-specific requirements, such as
radiological training, into site-specific implementation procedures for DOE
Facility Representatives.
1.2 Purpose of Program. The purpose of the DOE Facility Representative
Program is to ensure that competent DOE staff personnel are assigned to
oversee the day-to-day contractor operations at DOE’s hazardous nuclear
and non-nuclear facilities. Oversight performed by Facility
Representatives provides DOE line managers with accurate objective
information on the effectiveness of contractor work performance and
practices, including implementation of the integrated safety management
system. The Department’s experience has shown that when personnel
are dedicated to this function, the information that they provide can be
used proactively to ensure that work is completed in a safe and efficient
manner.
1.3 Purpose of Standard. The purpose of this standard is to help ensure that
DOE Facility Representatives are selected based on consistently high
standards and from the best qualified candidates available, that they
receive the training required for them to function effectively, and that their
expected duties, responsibilities, and authorities are well understood and
accurately documented. To this end, this guidance provides the following
practical information:
a. The duties, responsibilities and authorities expected of a Facility
Representative, and other personnel relative to the Facility
Representative Program.
b. An approach for use in determining the required facility coverage.
Section 4
c. The training and qualifications expected of a Facility Representative.
d. Elements necessary for successful Facility Representative Programs
at DOE Field Offices.
1.4 Applicability. This standard is intended for use by all DOE Components in
establishing and maintaining Facility Representative programs at DOE-
DOE-STD-1063-2006
2
owned, contractor-operated facilities. DOE Managers of government-
owned, government-operated facilities may apply this guidance to facilities
operated exclusively by DOE Federal employees. Field Element
Managers and Secretarial Officers may develop additional guidance
regarding Facility Representative requirements.
DOE-STD-1063-2006
3
2. REFERENCES
2.1 Government Documents. The following are references to the extent
specified herein.
2.1.1 DOE Directives (Policies, Orders, Manuals, Guides).
• DOE O 151.1B, Comprehensive Emergency Management System
• DOE P 226.1, Department of Energy Oversight Policy
• DOE O 226.1, Implementation of Department of Energy Oversight
Policy
• DOE M 226.1, Department of Energy Oversight Manual (draft)
• DOE O 231.1A, Environment, Safety and Health Reporting
• DOE M 231.1-2, Occurrence Reporting and Processing of Operations
Information
• DOE O 360.1B, Federal Employee Training
• DOE M 360.1-1B, Federal Employee Training Manual
• DOE M 411.1-1C, Safety Management Functions, Responsibilities,
and Authorities Manual [including the functions, responsibilities and
authorities documents specific to program offices and field elements]
• DOE O 414.1C, Quality Assurance
• DOE O 420.1A, Facility Safety
• DOE O 425.1C, Startup and Restart of Nuclear Facilities
• DOE P 426.1, Federal Technical Capability Policy for Defense Nuclear
Facilities
• DOE M 426.1-1A, Federal Technical Capability Manual
• DOE O 430.1B, Real Property Asset Management
• DOE O 440.1A, Worker Protection Management for DOE Federal and
Contractor Employees
• DOE O 442.1A, Department of Energy Employee Concerns Program
• DOE G 450.4-1B, Integrated Safety Management System Guide
• DOE P 450.7, Environment, Safety and Health (ESH) Goals
• DOE O 5480.19, Conduct of Operations Requirements for DOE
Facilities
2.1.2 DOE Standards.
• DOE-HDBK-1080-97, Guide to Good Practices for Oral Examinations
• DOE-HDBK-1204-97, Guide to Good Practices for the Development of
Test Items
• DOE-HDBK-1205-97, Guide to Good Practices for the Design,
Development, and Implementation of Examinations
• DOE-STD-1027-92, Hazard Classification and Accident Analysis
Techniques for Compliance with DOE O 5480.23, Nuclear Safety
Analysis Reports
DOE-STD-1063-2006
4
• DOE-HDBK-1118-99, Guide to Good Practices for Continuing Training
• DOE-STD-1146-2001, DOE General Technical Base Qualification
Standard
• DOE-STD-1151-2002, Facility Representative Functional Area
Qualification Standard
• DOE-STD-3006-2000, Planning and Conduct of Operational
Readiness Reviews
• DOE-STD-3009-94, Preparation Guide for U.S. DOE Nonreactor
Nuclear Facility Safety Analysis Reports
2.1.3 Other.
• 10 Code of Federal Regulations (CFR) Part 820, Procedural Rules for
DOE Nuclear Activities
• 10 Code of Federal Regulations (CFR) Part 830, Nuclear Safety
Management
• 10 Code of Federal Regulations (CFR) Part 850, Chronic Beryllium
Disease Prevention
• 10 Code of Federal Regulations (CFR) Part 851, Worker Safety and
Health Program
• DOE Implementation Plan for DNFSB Recommendation 92-2, DOE’s
Facility Representative Program at Defense Nuclear Facilities,
November 5, 1992
Section 5
• DOE Implementation Plan for DNFSB Recommendation 93-3,
Improving DOE Technical Capability in Defense Nuclear Facilities
Programs, May 5, 1998
• Principles for a Strong Nuclear Safety Culture. Institute of Nuclear
Power Operations, November 2004
• Effective Engineering Work Management, INPO 04-002. Institute of
Nuclear Power Operations, December 2004
• Guidelines for Effective Nuclear Supervisor Performance, INPO 04-
003. November 2004
2.2 Order of Precedence. In the event of conflict between the text of this
document and DOE Order, the DOE Order takes precedence. Nothing in
this document supersedes applicable laws and regulations.
DOE-STD-1063-2006
5
3. DEFINITIONS
For the purpose of this standard, the following terms are defined:
Activity Level. The frequency of handling or moving hazardous material, or the
frequency of activities involving one or more hazards creating an opportunity for
the occurrence of a reportable event (see Appendix C, PROCESS TO
DETERMINE FACILITY REPRESENTATIVE STAFFING, for activity level
determination) .
Cognizant Secretarial Officer. (DOE M 411.1-1C) The Secretarial Officers
responsible for accomplishing work in a safe and environmentally sound manner
at DOE-owned or DOE-leased sites and facilities (other than Headquarters).
Cognizant Secretarial Officers (CSOs) are Secretarial Officers with line
accountability for a laboratory or a bounded set of facilities. The CSOs provide
direction to line organizations in DOE HQ and the field regarding safety
management processes and systems. Although the ultimate responsibility for
safety rests with the Secretary, the CSOs are responsible for providing direction
to the line organizations in their assigned areas and they are accountable for the
appropriate and successful implementation of DOE policies and requirements
through their line organizations.
Core Qualification. The portion of the qualification program designed to cover
the DOE-wide, generic subjects on which all Facility Representatives are
expected to be knowledgeable. This includes the DOE General Technical Base
Qualification Standard (DOE-STD-1146-2001) and the DOE Facility
Representative Functional Area Qualification Standard (DOE-STD-1151-2002).
Contractor. Any person under contract with the Department of Energy, or
under sub-contract with a DOE contractor, with the responsibility to perform
activities in connection with any facility, laboratory, or program at a DOE-owned
or leased facility.
Department or DOE. The Department of Energy.
DOE Oversight. (DOE O 226.1) Encompasses activities performed by DOE
organizations to determine whether Federal and contractor programs and
management systems, including assurance and oversight systems, are
performing effectively and/or complying with DOE requirements. Oversight
programs include operational awareness activities, onsite reviews, assessments,
self-assessments, performance evaluations, and other activities that involve
evaluation of contractor organizations and Federal organizations that manage or
operate DOE sites, facilities, or operations.
Documented Safety Analysis. (10 CFR 830.204) Documented safety analysis
means a documented analysis of the extent to which a nuclear facility can be
operated safely with respect to workers, the public, and the environment,
DOE-STD-1063-2006
6
including a description of the conditions, safe boundaries, and hazard controls
that provide the basis for ensuring safety.
Section 6
Facility. (DOE O 430.1B) Land, buildings, and other structures, their functional
systems and equipment, and other fixed systems and equipment installed
therein, including site development features outside the plant, such as
landscaping, roads, walks, parking areas, outside lighting and communication
systems, central utility plants, utilities supply and distribution systems, and other
physical plant features.
Facility Representative. For each major facility or group of lesser facilities, an
individual assigned responsibility by the Field Element Manager (or designee) for
monitoring the safety performance of the facility and its operations. This
individual is the primary point of contact with the contractor for operational and
safety oversight and is responsible to the facility’s DOE Line Manager.
Facility Representative Coverage. The degree of attention a Facility
Representative is expected to devote to an assigned facility. Coverage is usually
expressed in terms of the amount of time, including back shift and weekend time,
that the Facility Representative is expected to routine ly spend observing
operations in the facility.
Field Element or Organization. A non-Headquarters DOE organization that is
geographically distinct. Field elements can be site offices, support offices,
operations offices, field offices, regional offices, or offices located at
environmental restoration, construction, or termination sites.
Field Element Manager. The DOE employee having overall responsibility for a
field element.
Hazard. (10CFR830.3) Hazard means a source of danger (i.e., material, energy
source, or operation) with the potential to cause illness, injury, or death to
personnel or damage to a facility or to the environment (without regard to the
likelihood or credibility of accident scenarios or consequence mitigation).
Hazard Categories. The consequences of unmitigated releases of radioactive
material are evaluated as required by 10CFR830, Nuclear Safety Management,
and classified by the following Hazard Categories:
Category 1 – The hazard analysis shows the potential for significant off-
site consequences.
Category 2 – The hazard analysis shows the potential for significant on-
site consequences.
Category 3 – The hazard analysis shows the potential for only significant
localized consequences.
Below Category 3 – Only consequences less than those that provide a
basis for categorization as a hazard category 1, 2, or 3 nuclear facility.
DOE-STD-1063-2006
7
DOE-STD-1027-92 contains additional information on methods and
criteria for determination of Hazard Categories.
Hazard Classes. (DOE-STD-3006-2000) Non-nuclear facilities are categorized as
high, moderate, or low hazards based on the following:
High – hazards with a potential for onsite and offsite impacts to large
numbers of persons or for major impacts to the environment;
Moderate – hazards which present considerable potential onsite impacts
to people or the environment, but at most only minor offsite impacts, and;
Low – hazards which present minor onsite and negligible offsite impacts to
people and the environment.
Section 7
Hazardous Material. (DOE-STD-3009-94) Any solid, liquid, or gaseous material
that is toxic, explosive, flammable, corrosive, or otherwise physically or
biologically threatening to health. Candidate hazards include radioactive
materials, hazardous chemicals as defined by OSHA in 29 CFR 1910.1200 and
29 CFR 1910.1450; any material assigned a reportable quantity value in 40 CFR
302, Table 302.4; threshold planning quantities in 40 CFR 355 Appendix A;
threshold planning quantities in 29 CFR 1910.119; level of concern quantities in
EPA’s “Technical Guidance for Hazard Analysis—Emergency Planning for
Extremely Hazardous Substances”; or materials rated as 3 or 4 in National Fire
Protection Association 704 “Identification of the Fire Hazards of Materials.”
(Another definition of hazardous material in 49 CFR 172 applies to hazardous
material that is to be transported in commerce.)
Headquarters Program Manager. A Headquarters organization, reporting to the
Cognizant Secretarial Officer, responsible for executing program management
functions, and for directing and supporting field elements in safety and health,
administrative, management, and technical areas.
Interim Qualification. Specific requirements that must be met prior to a Facility
Representative being assigned to provide limited coverage in a facility for which
he or she is not fully qualified.
Line Organization. The unbroken chain of command that extends from the
Secretary through the Deputy Secretary (Chief Operating Officer), to the
Secretarial Officers who set program policy and plans and develop assigned
programs, to the Program and Field Element Managers who are responsible for
execution of these programs, and to the contractors who conduct the programs.
Environment, Safety, and Health (ES&H) are integral parts of each program.
Accordingly, responsibility for ES&H functions resides with the line organizations.
Occurrence Report. (DOE M 231.1-2) A documented evaluation of an event or
condition that is prepared in sufficient detail to enable the reader to assess its
significance, consequences, or implications and to evaluate the actions being
proposed or employed to correct the condition or to avoid recurrence.
DOE-STD-1063-2006
8
Operational Awareness. (DOE O 226.1) Routine day-to-day monitoring of work
performance through facility tours/walk-throughs, work observation, document
reviews, meeting attendance and participation, and ongoing interaction with
contractor workers, support staff, and management.
Proficiency. The level to which a qualified Facility Representative stays current
on technical knowledge, assigned facilities, procedures, etc. Regaining
proficiency may be required by field element programs and procedures after an
absence from Facility Representative duties, a period of inactivity at a given
facility, as an ongoing training, or based on length of time between the Facility
Representative’s full qualification and next requalification date.
Qualification. The process of completing requirements determined to be vital to
performing the Facility Representative role in a given facility. This process
includes acknowledgment of the required education and experience, completion
of the core knowledge requirements to perform Facility Representative duties,
facility-specific requirements determined by the field element, and oral and
written examinations.
Section 8
Qualifying Official. An individual, designated by the Field Element Manager, or
designee, authorized to sign the qualification card after verifying the candidate
possesses the appropriate level of knowledge or skills for such signature.
Risk. (DOE-STD-3009-94) The quantitative or qualitative expression of possible
loss that considers both the probability that an event will occur and the
consequences of that event.
Secretarial Officer. (DOE M 411.1-1C) A manager who reports directly to the
Secretary, the Deputy Secretary or the Under Secretaries.
Training Equivalency. The completion of training requirements by an individual
through the means of prior experience or training, which results in comparable
knowledge or capabilities, equivalent to that which would be gained by complying
with the specified requirements. Prior experience and training is evaluated and
documented to demonstrate equivalency to the specified requirements.
Training Program. A planned, organized sequence of activities designed to
prepare persons to perform their jobs, to meet a specific position or classification
need, and to maintain or improve their performance on the job.
Walkthrough. Also referred to as a “walkdown.” A tour through a facility with a
qualifying official for the purpose of verifying a Facility Representative
candidate’s knowledge of the facility. Also, a tour through a facility to maintain
operational awareness of the facility.
DOE-STD-1063-2006
9
4. DUTIES, RESPONSIBILITIES, AND AUTHORITIES OF FACILITY
REPRESENTATIVES AND OTHER KEY PERSONNEL
4.1 Duties, Responsibilities, and Authorities of Facility Representatives. The
following paragraphs describe the duties, responsibilities, and authorities
normally expected of Facility Representatives. Field Element Managers
should tailor these and additional duties and responsibilities for Facility
Representatives to reflect the specific requirements of the site, the facility,
the operational activities, and the involved organizations.
4.1.1 Operational Awareness. A Facility Representative shall be thoroughly
familiar with site and facility characteristics, operating procedures,
facility authorization bases, operating organizational structure, and
key process control personnel. The Facility Representative shall be
aware of major work in progress and in planning. The Facility
Representative shall know which personnel are controlling the work,
what procedures are to be used, whether training and qualification
requirements have been established and are being met. Facility
Representatives shall verify that work activities are being performed
safely based on periodic observations and spot-check reviews of
frequency commensurate with the hazard and difficulty of the work.
This knowledge is primarily acquired by walking through the facility,
observation of work in progress, review of facility records and
documentation, and attendance at appropriate management
meetings of the operating contractor. Facility Representatives should
spend a significant amount of their time in their assigned facilities
observing operations and assessing operating conditions, consistent
with the goals in Appendix A , FACILITY REPRESENTATIVE
PERFORMANCE INDICATORS. Field Element Managers shall
ensure that operating contractors apprise Facility Representatives of
planning, scheduling, maintenance, operations review, and safety
review meetings.
Section 9
4.1.2 Communication. The Facility Representative shall maintain frequent
communication with field element supervision. The Facility
Representative shall ensure that DOE line management is cognizant
of current facility conditions.
4.1.3 Availability. The Facility Representative shall be available to respond
to facility events and serve as the DOE presence for special
operations. The Facility Representative shall be readily available to
operating contractor personnel to facilitate the notification, if required,
and reporting of occurrences and any safety or operational concerns.
4.1.4 Independence. A Facility Representative should be in a position to
provide information to DOE line management independent of
programmatic responsibilities. Therefore, Field Element Managers
DOE-STD-1063-2006
10
should not make Facility Representatives responsible for preparing
budgets or schedules for assigned facilities. In cases where it is
impractical to separate programmatic responsibilities, the Field
Element Manager or designee should approve all assignments of
programmatic responsibilities to Facility Representatives.
4.1.5 Scope of Reviews. The Facility Representative shall observe,
evaluate, and report on the effectiveness of the operating contractor
in multiple areas important to safe, efficient operations, such as
operational performance, quality assurance, management controls,
emergency response readiness activities, and assurance of worker
health and safety. In facilities where nuclear safeguards and security
are a concern, Facility Representatives may evaluate security issues
as they relate to safe operations. Additionally, the Facility
Representative should evaluate the overall effectiveness of the
operating contractor in implementing corrective actions to
deficiencies identified by facility reviews, including corrective actions
which stem from identifying, reporting, and tracking nuclear safety
noncompliance under the Price-Anderson Amendments Act of 1988.
The frequent presence of a Facility Representative in the facility is
intended and expected to improve communications between DOE
and the operating contractor. This improved communications is
intended and expected to lead to a better understanding of DOE
expectations by the contractor, and aid in the implementation of
enhancements to facility work practices and operating conditions.
4.1.6 Routine Activities. Facility Representatives should vary their day-to-
day presence in assigned facilities to show a degree of
unpredictability and spontaneity based on the Facility
Representative’s judgment regarding what is appropriate to observe
and assess. While there can be beneficial oversight achieved by
walking through assigned facilities with contractor facility managers,
certain benefits are lost when Facility Representative presence is
100% predictable and always with facility managers.
4.1.7 Stop Work Authority. The Facility Representative is assigned to
monitor the performance of facility operations and management. The
Facility Representative is a direct safety oversight extension of DOE
line management to each respective facility. The responsible Field
Element Manager shall define clearly the authority provided to each
Facility Representative. The Field Element Manager shall ensure that
Facility Representatives have the authority to “Stop Work” in the
facility. The Field Element Manager shall ensure that contractors and
subcontractors are aware that Facility Representatives have this
authority and that this authority covers all facility-related work
performed by the contractor and subcontractor. The Facility
Section 10
DOE-STD-1063-2006
11
Representative shall “Stop Work” in the following instances, as a
minimum:
a. Conditions exist that pose an imminent danger1 to the health
and safety of workers or the public.
b. Conditions exist, that if allowed to continue, could adversely
affect the safe operation of, or could cause serious damage to,
the facility.
c. Conditions exist, that if allowed to continue, could result in the
release, from the facility to the environment, of radiological or
chemical effluents that exceed regulatory limits.
4.1.8 Relationship of Facility Representative with DOE Managers. Facility
Representatives should periodically meet with line/program
managers within the field element and senior line managers within
the field element to provide information related to the assigned
facilities. If safety or operational concerns are not resolved to the
satisfaction of the Facility Representative, the Facility Representative
should elevate the concerns through the defined DOE management
hierarchy until an adequate resolution is obtained (see also Section
5.9). It is highly desirable that each Facility Representative only be
assigned facilities under a single line/program manager within the
field element and under a single Cognizant Secretarial Officer. This
might not be practical at multi-program facilities, or when more than
one facility is involved.
4.1.9 Relationship of Facility Representative with Other DOE Oversight
Personnel. Descriptions of Senior Technical Safety Managers and
Safety System Oversight and their relationships to Facility
Representatives can be found in DOE M 426.1-1A, Federal Technical
Capability Manual.
4.1.10 Relationship of Facility Representative with Operating Contractor.
Facility Representatives occupy a unique position in the transmission
of information between DOE and its contractors. Facility
Representatives should be able to communicate effectively with all
levels of the contractor organization. They should be familiar with the
contractor chain of command for facility operations. The Facility
Representative should always strive to work constructively and
effectively with contractor personnel to meet the shared goals of safe
and efficient facility operations, in accordance with relevant DOE and
contractual expectations. Facility Representatives should represent
DOE to the contractor and ensure the contractor carries out DOE
1 Any condition or practice such that a hazard exists that could reasonably be expected to cause death or serious physical
harm to employees (permanent or prolonged impairment of the body or temporary disablement or requiring
hospitalization), unless immediate actions are taken to mitigate the effects of the hazard and/or remove employees from
the hazard.
DOE-STD-1063-2006
12
operational safety policies in a manner consistent with DOE Program
Office and Field Element expectations, relevant contract
requirements, and the contractor’s Integrated Safety Management
System description. In defining the relationship between a Facility
Representative and contractor, the following points are emphasized:
a. The Facility Representative functions as a part of DOE line
management, and therefore should exercise authority consistent
with specific program and management guidance established by
the field element.
b. The Facility Representative is the primary point of contact for the
contractor to notify DOE of reportable occurrences as prescribed
in DOE M 231.1-2.
Section 11
c. The contractor is responsible for the safe and efficient operation
of the facility. The contractor is accountable to DOE to perform its
operations in a manner that ensures the safety and health of
personnel and protection of the environment. No Facility
Representative activity or inactivity can diminish the contractor’s
responsibility.
d. The Facility Representative is responsible for determining that the
contractor is operating the facility in a safe and efficient manner,
consistent with the established safety expectations and
requirements. Facility Representatives fulfill this responsibility by
assessing the contractor’s performance and discussing identified
deficiencies and corrective action with contractor management.
Field Element Managers should identify processes or procedures
within the field element for Facility Representatives to use to track
identified issues or discrepancies to satisfactory closure.
e. Although the Facility Representative identifies deficiencies, the
ultimate responsibility for identifying and correcting deficiencies
rests with the operating contractor. Field Element Managers
should ensure that the contractor does not rely solely on the
Facility Representative to identify or correct deficiencies.
f. Minor events or problems are frequently clues that indicate more
general problems in the contractor’s organization, management,
personnel abilities, or practices. Therefore, attention to detail in
the identification and correction of minor problems can result in
significant improvements in the contractor’s performance. When
corrective actions are called for, DOE line/program managers
should initiate formal action with the operating contractor.
Additionally, the Facility Representative should also provide input
to formal mechanisms such as confirmation of actions or orders, if
necessary.
g. The Facility Representative shall adhere to certain rules of
conduct, or protocol, while performing assigned duties, including
the facility’s approved conduct of operations procedures. Formal
protocols should be established to include the following:
DOE-STD-1063-2006
13
1. Facility Representatives should avoid interrupting operators in
their work. The Facility Representative should wait for
opportune times to deal with facility operators. If the Facility
Representative is observing operations or activities, the
Facility Representative should perform observations
unobtrusively. Operators carry the true burden of safety, and
a diversion from their duties could adversely affect plant
operations.
2. The Facility Representative should maintain frequent contact
with facility management. When Facility Representatives
observe something that raises a safety concern, they should
discuss their concerns with the facility management. If the
contractor response is deemed unsatisfactory, the Facility
Representative should discuss the concern with DOE line
management for appropriate action.
3. Facility Representatives should use established chains of
command for all requests for action, except when exercising
“Stop Work” authority.
4. Facility Representatives shall keep a record of their activities
and observations. Facility Representatives should periodically
review their records to determine if a systemic or recurring
problem exists with contractor activities at one or more
facilities. This record is subject to review in audits or
appraisals and may be used by the Field Element Manager as
a source of information for the contractor evaluation process.
Section 12
4.2 Duties, Responsibilities, and Authorities of Other Key Personnel. Duties,
responsibilities, and authorities of other key personnel with respect to the
Facility Representative program are described below and in DOE M
231.1-2, Occurrence Reporting and Processing of Operations Information,
DOE O 5480.19, Conduct of Operations for DOE Facilities, and DOE M
411.1-1C, DOE Safety Management Functions, Responsibilities, and
Authorities Manual, and associated lower-tier functions and
responsibilities documents.
4.2.1 Deputy Secretary.
a. Establish DOE policy on Facility Representatives.
b. Resolve any cross-organizational disputes regarding Facility
Representatives.
c. Ensure the Facility Representative Program Manager and Cognizant
Secretarial Officers take actions necessary to consistently meet
program goals.
DOE-STD-1063-2006
14
4.2.2 Facility Representative Program Manager.
a. Guide DOE-wide program implementation and continuous
improvement.
b. Monitor DOE-wide implementation performance and disseminate
information to senior DOE and NNSA managers to promote improved
performance.
c. Sponsor an annual workshop to share lessons learned and promote
continued effectiveness of the Facility Representative program.
d. Participate in periodic assessments of site Facility Representative
programs.
4.2.3 Cognizant Secretarial Officers.
a. Designate a representative to assist in fulfilling these responsibilities.
b. Review overall effectiveness of Facility Representative programs at
assigned field elements, including performance indicator information
and accomplishment of program self-assessments and associated
corrective actions.
c. Ensure adequate allocation and use of resources for Facility
Representative programs at assigned field elements.
d. Monitor and validate the number of Facility Representative positions
filled with qualified personnel to ensure that adequate Facility
Representative coverage is provided.
e. Provide developmental opportunities for Facility Representatives.
4.2.4 Field Element Managers.
a. Determine facility coverage needs and make assignments of qualified
Facility Representatives to maintain day-to-day oversight of
applicable facilities, using Appendix C, PROCESS TO DETERMINE
FACILITY REPRESENTATIVE STAFFING.
b. Select, train, and qualify Facility Representatives so that they are
capable of performing their assigned duties.
c. Clearly define the functions, responsibilities and authorities of the
Facility Representatives, and ensure that affected DOE and
contractor managers understand the role of the Facility
Representatives and provide the necessary access and support.
d. Establish a formal protocol for Facility Representatives to follow while
performing their duties.
e. Periodically evaluate the effectiveness of the field element’s Facility
Representative program and pursue changes to improve overall
performance and effectiveness, using Appendix A, FACILITY
REPRESENTATIVE PERFORMANCE INDICATORS, and Appendix
B, FACILITY REPRESENTATIVE PROGRAM ASSESSMENT
GUIDE.
DOE-STD-1063-2006
15
f. Provide developmental opportunities for Facility Representatives.
Examples of such opportunities could be short-duration details to
other organizations or specialized training.
g. Assign a Facility Representative Program Sponsor from among the
field element’s senior managers to guide and direct implementation
within the field element.
Section 13
h. Establish the authority of the Facility Representative to represent line
management to the contractor regarding operational safety issues,
except where this would change scope, cost, or schedule.
i. Interact frequently with Facility Representatives and take appropriate
action to resolve identified safety and management issues.
4.2.5 Facility Representative Program Sponsors.
a. Serve as a management advocate for Facility Representatives within
the field element to resolve programmatic issues.
b. Guide and direct Facility Representative program implementation
within the field element.
c. Ensure that Facility Representatives are effectively contributing to the
field element, and DOE line/program managers are effectively using
their contributions.
d. May appoint or secure the appointment of a Facility Representative
Program Manager to manage day-to-day implementation issues for
the field element and participate in Facility Representative Steering
Committee discussions.
DOE-STD-1063-2006
16
5. FACILITY REPRESENTATIVE PROGRAM REQUIREMENTS
5.1 Facility Coverage and Staffing. Field Element Managers shall evaluate
each hazardous facility to determine an appropriate level of Facility
Representative coverage. Appendix C, PROCESS TO DETERMINE
FACILITY REPRESENTATIVE STAFFING, provides a detailed process to
determine appropriate facility coverage and assignment and is the
expected methodology to be used. The Field Element Manager, or
designee, should prepare staffing plans to document these assignments
and supporting rationale.
a. Field Element Managers shall assign one or more full-time Facility
Representatives to each hazard category 1 facility, unless the Field
Element Manager and Cognizant Secretarial Officer agree that less
coverage is necessary. For nuclear hazard category 2 or 3 facilities,
radiological facilities, and hazardous non-nuclear facilities, Field
Element Managers may assign a Facility Representative to two or
more facilities. In unusual situations, when it is impractical to assign a
sufficient number of facilities to occupy a person full-time, the Field
Element Manager may assign the duties of a Facility Representative to
be performed part-time as a collateral function.
b. It is important that a Facility Representative’s primary duty of providing
DOE an on-site presence not be diminished. Field Element Managers
should make assignments so that Facility Representatives spend a
significant portion of their time in their assigned facility(s). It is
preferable that Facility Representative offices be located within the
facility of primary responsibility. Field Element Managers should make
assignments so that administrative work does not prevent Facility
Representatives from performing their primary function of monitoring
the performance of the facility and its operations as described in
Section 5.2.
c. To the degree that Facility Representatives are advanced or otherwise
lost from the program, Field Element Managers should take necessary
steps to ensure departing Facility Representatives are replaced in a
timely manner. The goal of the Field Element Manager should be to
recruit and hire technically capable personnel to fill Facility
Representative vacancies in an expeditious manner. Recognizing the
lengthy average time for a new Facility Representative candidate to
achieve full qualifications (i.e., approximately 18 months), Field
Element Managers should strive to recruit experienced candidates
from technically rigorous programs, both from within DOE and from
external sources, to minimize time in qualification. Such potential
sources include DOE Safety System Oversight personnel, DOE
Subject Matter Expert personnel, and personnel from directly related
fields such as naval nuclear power, commercial nuclear power,
Section 14
DOE-STD-1063-2006
17
radioactive waste management, nuclear weapons, nuclear research,
industrial safety, chemical safety, or accelerator facility programs.
Section 5.7 contains additional guidance.
d. As part of the overall staffing strategy, Field Element Managers should
also consider making use of existing DOE and NNSA technical intern
programs to provide a source of prospective Facility Representatives
candidates, especially for sites that have experienced historically high
attrition rates.
e. Field Element Managers should review staffing plans and assignments
of Facility Representatives at least annually to ensure that coverage
assignments and responsibilities are appropriate to the hazards and
level of activity involved.
f. Field Element Managers may also establish provisions for changing
coverage. For example, as the degree of hazard, complexity, or other
governing factors is reduced, the Field Element Managers may
increase the number of processes, facilities, buildings or areas covered
by a single Facility Representative. Field Element Managers may use
special coverage assignments for a facility that operates only
intermittently. Also, Field Element Managers should consider
periodically rotating Facility Representatives to different facilities to
maintain objective oversight, to broaden Facility Representative’s
experience base, and to provide flexibility for backup coverage during
periods when Facility Representatives are absent.
g. Field Element Managers should make Facility Representative
assignments to optimize effective interaction with the facility operating
organization line management responsible for ensuring safe and
efficient performance at the facility. For example, Field Element
Managers may make assignments based on facility and/or operating
organization subdivisions. If the contractor has established a building
or facility manager concept, the Field Element Manager may assign
Facility Representatives on a similar basis.
5.2 Facility Assessment Plans and Reports. Field Element Managers should
develop facility assessment plans using a tailored approach to ensure that
a broad-based and systematic review of all aspects of facility operations is
conducted over an established period of time. Assessment plans may
include DOE O 5480.19, Conduct of Operations Requirements for DOE
Facilities, and associated standards, and other safety directives. These
assessment plans should be consistent with the requirements in DOE O
226.1, Implementation of Department of Energy Oversight Policy. Facility
assessments are not intended to conflict with or duplicate other Field
Office assessment efforts nor are they intended to unduly restrict the
Facility Representative’s day-to-day oversight of assigned facilities.
DOE-STD-1063-2006
18
a. Field Element Managers, or designee, should establish reporting
requirements, such as Facility Representative logs or assessment
reports, for each Facility Representative position. Field Element
Managers should establish guidance on the content of periodic or
special reports.
b. Field Element Managers should ensure that reporting does not
become an onerous task that unduly limits the oversight activities of
the Facility Representative. In order to facilitate a direct
communications link with senior contractor management, the Facility
Representative and DOE managers should meet with senior contractor
managers on a periodic basis to report the results of Facility
Representative assessments and to discuss trends and systemic
issues.
Section 15
5.3 Unencumbered Access. Field Element Managers shall ensure that
Facility Representatives have independent and direct access to contractor
personnel, facilities, and records, as necessary, to carry out their assigned
responsibilities. Unencumbered and immediate access does not preclude
a Facility Representative from following industrial safety, emergency
action, radiation protection, safeguards and security, or operational
requirements and controls of the facility. Facility Representatives shall
adhere to these requirements and controls when discharging their duties.
a. Field Element Managers shall ensure that Facility Representatives
have immediate unannounced access to every assigned facility,
consistent with necessary security and safety controls. Facility
Representatives shall maintain the proper clearances, training,
personal protective equipment, and physical qualifications for such
access.
b. Field Element Managers shall ensure that contractor management
affords the Facility Representative the opportunity to attend meetings,
training classes, operator certification boards/examinations, etc., that
contribute to the execution of the duties and responsibilities of the
Facility Representative.
c. Access to some contractor records may be limited as specified in the
contract between DOE and the contractor. For example, the contract
may include an item such as DEAR 970.5204-79 “Access to and
Ownership of Records” which sets forth certain categories of records
which may be considered to be the property of the contractor.
d. Due to safeguards and security requirements, Field Element Managers
may require that more than one properly trained and cleared individual
be present before access can be gained to some areas.
DOE-STD-1063-2006
19
5.4 Training. Field Element Managers shall train Facility Representatives in
accordance with DOE O 360.1B, Federal Employee Training with
additional elements defined in this standard. Facility Representative
supervisors should ensure that training materials, qualification cards, and
examinations are periodically updated to reflect changing facility
conditions and new or updated DOE directives.
5.4.1 Needs Analysis. Facility Representative supervisors should ensure an
analysis of the candidate’s initial training needs is conducted. This is the
process by which the tasks, duties, and responsibilities of the position
are analyzed to identify formal or informal training, self-study, seminars,
on-the-job-training, briefings, rotational assignments, or other types of
training necessary for effective job performance.
5.4.2 Formal Training. Field Element Managers should ensure that the Facility
Representatives receive the training necessary for the position.
Frequently, appropriate courses and training can be found within the
DOE complex, other Federal agencies, or from non-government sources
within the scientific community to satisfy some of the training needs.
Headquarters offices, in coordination with the field elements, can
develop additional training courses and material to help meet the non-
facility-specific Facility Representative training needs. Close
collaboration among field elements and Headquarters line management
is encouraged to minimize development costs for courses. In cases
where formal course work is not practical, Field Element Managers
should ensure that informal training provides Facility Representatives the
required level of knowledge.
Section 16
5.4.3 On-the-Job Training . Field Element Managers should establish the “On-
the-Job Training” requirements, regarding the controls, activities,
processes, and specialized procedures necessary for qualification.
Practices such as mentoring of Facility Representative candidates by
qualified, experienced Facility Representatives and providing ample
opportunities for candidates to participate in facility operational
awareness activities are encouraged.
5.4.4 Continuing Training. Field Element Managers should establish a
continuing training program to enhance and strengthen the knowledge,
skills and abilities of Facility Representatives, to ensure they are aware
of significant new hazards or activities they may encounter during the
performance of their duties, and to provide a mechanism to share
lessons learned from facilities on the site and across the complex.
Guidance in Appendix D, CONTINUING TRAINING GUIDANCE, should
be used.
5.5 Qualification. Field Element Managers shall qualify each Facility
Representative by a combination of education, experience, and training to
DOE-STD-1063-2006
20
carry out the duties and responsibilities of the position. Facility
Representatives are required to meet stringent and comprehensive
qualification standards. Field Element Managers shall qualify Facility
Representatives as possessing a broad technical knowledge in a variety
of disciplines and being able to demonstrate an understanding of the
management, processes, practices, regulatory requirements, and
operating limits of their assigned facilities. The Field Element Manager
shall develop the overall qualification program, in accordance with DOE M
426.1-1A, Federal Technical Capability Manual, and DOE M 3601.1-1B,
Federal Employee Training Manual, including training elements specific to
the assigned facilities and systems. Field Element Managers shall define
and document the qualifications, and authority of personnel involved in the
training of Facility Representatives. The steps involved in the various
levels of qualifications are described below and in Table 1 – Facility
Representative Qualification.
5.5.1 Qualification Card. Field Element Managers should establish a Facility
Representative qualification card (“qual card”) or equivalent for each
major facility or group of lesser facilities for which they are responsible.
The qual card contains a list of all of the training elements or learning
objectives, a corresponding standard detailing the required level of
knowledge for each objective, and provisions for signatures to attest to
satisfactory completion of each objective to the appropriate level of
knowledge. If training equivalencies are used, Field Element Manager
should provide justification for each equivalency based on DOE M 426.1-
1A. Justification includes appropriate support documentation such as
transcripts or certificates of completion. Field Element Managers shall
maintain a copy of the approved equivalency in the Facility
Representative’s qualification record. Additionally, the Field Element
Manager should designate qualifying officials who are authorized to sign
the qual card after verifying the candidate possesses the appropriate
level of knowledge for each requirement. The qual card should include
the following:
a. Self Study. Site and facility-related DOE Directives and Standards,
Section 17
Federal and State safety and environmental protection regulations
applicable to the assigned site and facility, the facility safety
documentation, and all site and facility-specific documents and
procedures that are pertinent to the responsibilities of the Facility
Representative.
b. Formal Training. Formal training, both on-site and off, necessary
for the Facility Representative to function effectively. The training
may be presented by DOE, contractors, other Federal Agencies, or
private firms.
DOE-STD-1063-2006
21
c. On-the-Job Training . Knowledge of facility processes, systems
requirements, and specialized procedures required to be
demonstrated to a qualifying official.
d. Facility Walkthroughs. A walkthrough o f the assigned facilities, in
the presence of a qualifying official, for the purpose of
demonstrating practical skills and thorough knowledge of selected
key elements or systems of the facility.
5.5.2 Core Qualification. Core qualification requirements are the DOE General
Technical Base Qualification Standard (DOE-STD-1146-2001) and the
DOE Facility Representative Functional Area Qualification Standard
(DOE-STD-1151-2002). It is acceptable to have one qual card that
covers both Core and site/facility-specific requirements.
5.5.3 Interim Qualification. DOE Field Element Managers shall establish and
document the process and the specific requirements to be met prior to a
Facility Representative candidate being assigned to provide interim
coverage in a facility for which he or she is not fully qualified. Field
Element Managers shall formally define and document the duties and
authorities that may be assigned to an Interim Qualified Facility
Representative. Field Element Managers should minimize the time
spent as a Facility Representative under Interim Qualification. The Field
Element Managers should also determine the compensatory measures
to be implemented during interim periods while no fully qualified Facility
Representative is assigned to a given facility.
5.5.4 Full Qualification. Full qualification occurs upon completion of Core
Qualification, site/facility-specific competencies designed to meet the
needs of the individual facility, a facility walkthrough, a written exam, and
an oral board. Designated facility line managers within the field element
should review and confirm satisfactory completion of the training and
qualification requirements and eligibility of the candidate to become a
Facility Representative. Qualification is granted by the Field Element
Manager or designee.
5.5.5 Qualification on Additional Facilities After Full Qualification. Upon
assignment of Facility Representatives to a different or additional facility
or site, Field Element Managers or their designees should identify any
additional qualification requirements that are necessary for a Facility
Representative to complete for that facility or site . As a minimum, the
additional qualification requirements should consist of the qual card for
the new facility, a walkthrough, and a written and/or oral exam.
5.5.6 Requalification. Facility Representatives shall requalify every three
years. The Field Element Manager shall establish processes or
procedures to ensure the three year time limit for requalification is not
DOE-STD-1063-2006
22
Section 18
exceeded. The Field Element Manager, or designee, may extend the
three-year period up to six months for extenuating circumstances. The
purpose of triennial qualification is to ensure the incumbent Facility
Representative maintains the knowledge and skills necessary to properly
perform Facility Representati ve duties at the assigned facilities. At the
time of requalification the Facility Representative will be currently fully
qualified and meet proficiency requirements at the assigned facility or
facilities, and exhibit satisfactory performance as is documented by the
past three performance appraisals. DOE Field Element Managers shall
document the requalification process, which shall as a minimum include
the following:
a. Items added to the Facility Representative Qualification Cards
since the individual’s last qualification or requalification, including
General Technical Base, Facility Representative Functional Area
Qualification Standard, and applicable Site Specific Qualification
Standards.
b. Determination by the Facility Representative’s supervisor what
system, process, and facility documentation changes have
occurred since qualification (or the last requalification) that are to
be included for examination.
c. Determination by the Facility Representative’s supervisor, based on
demonstrated performance, any areas of theory or fundamentals, if
any, which should be included for examination.
d. A written examination and/or oral checkout covering the material
included for requalification examination.
e. Certification of requalification is granted by the DOE Field Element
Manager or designee.
5.5.7 Proficiency. Field Element Managers shall formally define proficiency
requirements. These requirements shall include actions required to
regain proficiency following periods of inactivity as a Facility
Representative, and the length of time which triggers a need for
proficiency training. For example, if a Facility Representative is no
longer assigned to a facility but wishes to maintain proficiency, the
Facility Representative should periodically participate, either in their
normal role or as observers, in in-plant drills. Qualifications to regain
proficiency after inactivity as a Facility Representative are shown in
Table 1 – Facility Representative Qualification.
5.5.8 Examinations. The Field Element Manager, or designee, should develop
formal procedures for the administration of facility walkthroughs, and
DOE-STD-1063-2006
23
written and oral examinations. Additional information on examinations is
available in DOE-HDBK-1204-97 and DOE-HDBK-1205-97.
a. Facility Walkthroughs. Field Element Managers sha ll establish
requirements for facility walkthroughs of assigned facilities at
selected points in the Facility Representative qualification process
for demonstrating to a qualifying official practical skills and
knowledge of selected key elements, including safety systems,
structures, and components of the facility.
b. Written Examinations . During Full Qualification, Field Element
Manager or designee shall administer a written examination to the
Facility Representative candidate as listed in Table 1 – Facility
Representative Qualification. The examination should include only
subjects on the Facility Representative core and facility-specific
qual cards. The minimum passing grade should be 80%.
Section 19
c. Oral Examinations. For a Facility Representative to achieve Full
Qualification, the Field Element Manager or designee shall convene
and chair a Qualification Board for the purpose of conducting an
oral examination of the Facility Representative candidate. The
Field Element Manager or designee shall determine the
composition of the Qualification Board. Board members should ask
critical questions intended to integrate identified learning objectives
during qualification. Additionally, the Board members may ask
follow-up questions to help the Board determine how the
candidates “think on their feet.” Field Element Managers or
designees should develop formal guidance for the Qualification
Board; this guidance includes: the standards for Qualification, the
use of technical advisors by the Board, the questioning procedures
or protocol, pass/fail criteria, the voting authorization and
procedures, and the Board deliberation and documentation
process. The Board may conduct the oral exam as a group or
individually. The Board should document explicitly any questions
and answers that result in an oral exam failure. Other types of oral
exams (e.g., oral checkouts) may be used in Facility
Representative qualification as shown in Table 1 – Facility
Representative Qualification.
d. Failure of Written or Oral Examinations. Field Element Managers
or their designees may require Facility Representative candidates
who fail a written or oral examination to go on a special study
program designed to strengthen each area of weakness revealed in
the examination. Field Element Managers or their designees may
direct candidate reexaminations, with concentration in the identified
weak areas. Field Element Managers should reassign Facility
Representative candidates who repeatedly fail examinations, to a
DOE-STD-1063-2006
24
non-Facility Representative position. In rendering a final decision
on reassignment, the Field Element Manager should consider any
extenuating circumstances.
5.6 Designated Facility Representatives. Field Element Managers may
establish criteria for designating Facility Representatives. For example, to
become “Designated” a Facility Representative should be core qualified
(i.e., complete the DOE-STD-1146-2001, DOE General Technical Base
Qualification Standard and the DOE-STD-1151-2002, DOE Facility
Representative Functional Area Qualification Standard) and have at least
six months experience in a Facility Representative position. The purpose
of this “Designation” is to indicate unique technical proficiency for the
purposes of retention based upon unique competitive level codes.
Designation is not equivalent to full qualification as designation will
normally occur before a Facility Representative achieves full qualification.
Some Field Element Managers designate Facility Representatives at the
completion of interim qualifications.
Section 20
5.7 Recruitment, Selection, Retention, and Advancement Considerations. As
qualified Facility Representatives gain experience, they become a
valuable resource of DOE. Field Element Managers should take
necessary steps to ensure that Facility Representative positions are
career enhancing and remain desirable to Facility Representative
candidates. This includes incentives to maintain qualification, and the
encouragement of skills enhancement through continuing training,
graduate study, and professional certifications. In addition, Field Element
Managers and Cognizant Secretarial Officers should provide opportunities
for Facility Representatives to develop management skills. This
experience and training can make Facility Representatives with solid
technical and management skills into prime candidates for positions of
higher responsibility both in the field and at DOE Headquarters. Field
Element Managers and Cognizant Secretarial Officers should identify
these developmental experiences and training opportunities in the
personnel development plans for their organizations, and in the Facility
Representatives’ Individual Development Plans. DOE P 426.1, Federal
Technical Capability Policy for Defense Nuclear Facilities, and DOE M
426.1-1A, Federal Technical Capability Manual, provide various
mechanisms that can be used to retain these valuable resources.
DOE-STD-1063-2006
25
Table 1 – FACILITY REPRESENTATIVE QUALIFICATION
QUALIFICATION
PROCESS
DOE-STD-
1146-2001,
General
Technical
Base
Qualification
Standard
DOE-STD-
1151-2002,
FR
Functional
Area
Qualification
Standard
Site-/Facility-
Specific
Competencies
Facility
Evaluated
Walkthrough
Exam
Type
Oral
Board
[Note 4]
1. Core
Qualification
X
[Note 1] X - -
Written
[Note 2] -
2. Interim
Qualification
X
[Note 1] X
And as determined by the Field Element Manager
when a FR provides interim coverage in a facility for which
he or she is not fully qualified.
3. Full
Qualification
Core Qualified as Noted in
Row 1, and à
X X
Written
[Note 2]
X
4. Qualification
on additional
facilities after
Full
Qualification
- - X X
Written
and/or Oral
checkout
[Note 4]
-
5. Periodic
Requalification
[Note 3]
Items added, and areas of
theory or fundamentals, if
any, as determined by the
Supervisor.
Changes to
system,
process, and
facility
documentation,
as determined
by the
Supervisor.
-
Written
and/or Oral
checkout
[Note 4]
-
6. To regain
proficiency after
inactivity as a
FR
Any items
added
Any items
added
Any items
added
X
Written
and/or Oral
checkout
[Note 4]
-
Notes:
1. Satisfactory completion of the General Technical Base Course on the DOE Online
Learning Center may be used.
2. Written exams for Core Qualification and Full Qualification may be combined into a
single written exam.
3. The steps in Row 5, Periodic Requalification, may be combined with steps in Rows 4
and/or 6 to meet those qualifications concurrently, if necessary.
4. Oral boards and oral checkouts are described in more detail in DOE-HDBK-1080-97,
Guide to Good Practices for Oral Examinations.
DOE-STD-1063-2006
26
5.7.1 Recruitment and Selection. Field Element Managers should develop
position descriptions and vacancy announcements that reflect the
requirements of this standard. Several mechanisms available to assist
field elements in the recruitment of high quality candidates necessary for
their program are identified in the DOE M 426.1-1A, Federal Technical
Capability Manual. In order for individuals to enter a Facility
Representative training and qualification program with the greatest
opportunity for successful completion, Field Element Managers should
select candidates based on the following selection criteria.
Section 21
a. Education Requirements. Educational requirements are necessary
to ensure that the individuals possess the baseline knowledge to
successfully complete the training program, the ability to function
independently in the field, and the ability to understand scientific
principles and communicate in technical terms. Field Element
Managers should establish expected minimum education
necessary to provide competent technical assessment of the
contractor. Minimum education level is expected to be a
Baccalaureate degree or equivalent technical degree. Alternately,
completion of an appropriate formal training program and extensive
experience in a directly related field such as naval nuclear power,
commercial nuclear power, radioactive waste management, nuclear
weapons, nuclear research, industrial safety, chemical safety, or
accelerator facility programs is also sufficient.
b. Experience Requirements. Field Element Managers should also
establish and apply facility-specific experience criteria as part of the
selection criteria for Facility Representative candidates. The
facility-specific experience criteria should reflect the complexity,
hazard classification, and activity level of the facility and be
commensurate with the responsibilities, authority and duties of the
assigned position.
c. Physical Requirements. Field Element Managers should also
establish and apply appropriate physical requirements. For
example, most positions require moderate exertion, such as
walking over uneven surfaces; climbing over equipment,
machinery, ladders, and scaffolding; crouching, bending, stooping,
stretching; and moving in confined spaces. Most positions also
involve regular and recurring exposure to moderate risks and
discomforts from use of protective clothing in elevated
temperatures, close proximity to moving machinery, heavy
equipment, hoisting and rigging activities; potential exposure to
hazardous and radioactive materials, and exposure to normal
industrial and chemical hazards. Safety and protective clothing and
equipment such as respirators, safety shoes and glasses, ear
protection, dosimeters, or other equipment is usually necessary.
DOE-STD-1063-2006
27
The use of emergency protective equipment may involve significant
exertion over extended periods of time. Facility Representatives
need to be comfortable working in what is often an industrial
environment.
d. Security Requirements. Field Element Managers should also
establish and apply appropriate security requirements so that the
Facility Representatives have adequate security clearances to fulfill
their duties.
5.7.2 Retention and Advancement. Several mechanisms are available to
assist field elements in the retention of high quality personnel necessary
for their program. Field Element Managers should seek to understand
reasons for unusually high Facility Representative attrition rates and
counter those reasons using appropriate mechanisms. These
mechanisms may include:
a. Recognition and real-time management acknowledgement;
b. Access and interaction with senior DOE and Facility Managers,
such as on joint-walkthroughs and feedback meetings;
c. Mentoring from senior DOE and Facility Managers;
d. Qualification bonuses;
e. Performance bonuses;
f. Requalification bonuses;
g. Anniversary bonuses;
h. Educational reimbursement incentives;
i. Quality Step Increases based on experience and performance;
j. Higher GS Grade based on higher facility hazard category;
k. Higher GS Grade based on scope of facility assignments;
l. Higher GS Grade for Facility Representative Program Managers,
Section 22
Supervisors, and Team Leaders; and
m. Promotions based on knowledge and experience.
5.8 Facility Representative Program Performance Assessment and Feedback.
Field Element Managers shall periodically evaluate and adjust their
Facility Representative program as necessary to ensure a high and
continuously improving level of performance. Cognizant Secretarial
Officers should ensure that performance assessments are accomplished,
and any indicated corrective actions are completed. The DOE
Headquarters Facility Representative Program Manager, Office of the
Departmental Representative to the Defense Nuclear Facilities Safety
Board (DOE DR-1), should monitor the performance of Field Element
Managers and Cognizant Secretarial Officers using the following methods.
5.8.1 Performance Indicators. Carefully chosen performance indicators (PI)
can provide valuable measures of the effectiveness of Facility
Representative Programs. DOE-wide Performance Indicators,
DOE-STD-1063-2006
28
addressing compliance to program requirements, improvements to
safety, and performance effectiveness, are shown in Appendix A. Field
elements may provide additional site-specific performance indicators.
Field elements shall submit quarterly PI data to Program Offices at DOE-
HQ, with a copy to the Facility Representative Program Manager, Office
of the Departmental Representative to the Defense Nuclear Facilities
Safety Board (DOE DR-1). PIs for the preceding quarter are due to HQ
on the first working day of February, May, August, and November. The
Facility Representative Program Manager, Office of the Departmental
Representative to the Defense Nuclear Facilities Safety Board (DOE
DR-1), should use these PIs to evaluate DOE-wide program
effectiveness. The Facility Representative Program Manager, Office of
the Departmental Representative to the Defense Nuclear Facilities
Safety Board (DOE DR-1), shall compile a Department-wide PI report for
dissemination to applicable field elements and program offices.
5.8.2 Field Element Self-Assessments. Field Element Managers shall ensure
that periodically (not to exceed three years) their Facility Representative
Programs are evaluated relative to the requirements in Sections 4 and 5
of this standard. Field Element Managers should use evaluators who
have adequate knowledge and experience to conduct meaningful
reviews and provide the results of these self-assessments to the
responsible Program Office at DOE-Headquarters, with a copy to the
Facility Representative Program Manager, Office of the Departmental
Representative to the Defense Nuclear Facilities Safety Board (DOE
DR-1). Guidance for the performance of these assessments is provided
in Appendix B.
5.8.3 Peer Reviews. Field Element Managers, or designee, should invite
Facility Representatives and/or Facility Representative management
from other sites to perform peer reviews of their Facility Representative
programs. These reviews may be accomplished as part of the periodic
self-assessment described in section 5.8.2. Peer reviews can provide a
mutual benefit through sharing lessons learned and can foster a more
consistent Facility Representative program throughout the DOE.
Section 23
5.8.4 Annual Facility Representative Workshop. The Facility Representative
Program Manager, Office of the Departmental Representative to the
Defense Nuclear Facilities Safety Board (DOE DR-1), should host an
Annual Facility Representative Workshop to share lessons learned about
operations at hazardous DOE facilities and to share information about
the Facility Representative Programs across the complex. Field Element
Managers should encourage as many Facility Representatives, Facility
Representative Program Sponsors, and line managers as possible to
attend the workshops to share information with other sites and identify
potential improvements for use in their own Facility Representative and
Safety Management programs.
DOE-STD-1063-2006
29
5.8.5 Communication and Feedback Mechanisms. The Facility
Representative Program Manager, Office of the Departmental
Representative to the Defense Nuclear Facilities Safety Board (DOE
DR-1), should communicate with the Cognizant Secretarial Officers and
Field Element Managers frequently to guide the program implementation
and continuous improvement. This can be accomplished by:
a. Discussions with the Program Sponsors on strategic goals and
plans;
b. Facility Representative Steering Committee meetings; and
c. Information sharing through the Facility Representative Home Page
(http://www.facrep.org).
5.9 Differing Professional Opinions. One of the root causes of the February
2003 Columbia Space Shuttle accident identified by the Columbia
Accident Investigation Board was that organizational barriers had become
established within the National Aeronautics and Space Administration that
prevented effective communication of critical safety information and stifled
professional differences of opinion. Because Facility Representatives have
the professional obligation to inform management of safety information
that may affect the health and safety of the public and/or workers, Field
Element Managers should strive to develop and maintain an open
atmosphere for the exchange of views of a technical nature. Facility
Representatives, as well as other technical oversight personnel, should
provide information to management regardless of whether it may be
different from the prevailing view, disagree with a management decision or
policy position, or take issue with a proposed or established practice. This
information should receive an appropriate level of review for resolution of
any safety issues. If necessary, Facility Representatives are encouraged
to use existing procedures or follow existing guidance on resolving
differing professional opinions. DOE O 442.1A, Department of Energy
Employee Concerns Program, provides a process for resolving concerns
that may arise. Also, the Department recently developed and promulgated
draft DOE P 442.1, Differing Professional Opinions and draft DOE M
442.2-1, Differing Professional Opinions Manual for Technical Issues
Involving Environment, Safety, or Health.
DOE-STD-1063-2006
Appendix A
A-1
FACILITY REPRESENTATIVE PERFORMANCE INDICATORS
Scope: Carefully chosen Performance Indicators (PIs) can provide valuable
measures of the effectiveness of Facility Representative Programs. These PIs
will be used by Field Element Managers and DOE-HQ personnel to evaluate
program effectiveness. Other PIs may be useful at a local level to determine the
need for local program changes, depending on circumstances that may be
unique to a site. DOE-wide Facility Representative PIs are relatively few in
number, easy to measure and report, applicable to all Facility Representative
Programs, and resistant to misinterpretation. Since effectiveness in providing
contractor oversight may be difficult to capture in measurable terms, some
subjective measures are used.
Section 24
General Points:
1. The attached Performance Indicators are for DOE-wide use. Field elements
may use additional, local PIs that suit their own needs.
2. PIs for DOE-wide use are divided into the following categories: Staffing,
Training and Qualification, Facility Representative Program
Accomplishments, and Fulfilling the Facility Representative Role.
3. PIs that measure contractor performance have been avoided as measures of
Facility Representative program effectiveness.
4. PIs shall be reported by the Field Element Managers to program offices
quarterly, with a copy sent to the Facility Representative Program Manager,
Office of the Departmental Representative to the Defense Nuclear Facilities
Safety Board (DOE DR-1). At the close of a given quarter, one month is
allocated to assemble PI reports, which are then due on the first working day
of the months of February, May, August, and November.
5. Performance Indicators, their methods of calculation, and goals (or targets)
are presented in the following tables.
DOE-STD-1063-2006
Appendix A
A-2
STAFFING
TYPE INDICATOR NAME HOW TO CALCULATE GOAL
DOE-
wide
Staffing level (%)
Number of Facility Representative
positions filled
Number of Facility Representative
positions (per DOE-STD-1063-
2006)
[Indicate if the authorized
FTE level is different than
the staffing level per DOE-
STD-1063-2006]
100% of [#Facility
Representatives]
DOE-
wide
Attrition
Number of Facility
Representatives leaving the
program this quarter. Provide
reason for attrition using the
following options: Transfer,
Promotion, Lateral, Retirement, or
Resignation.
[Definitions: Transfer - Takes a
Facility Representative job at
different site; Promotion - Takes
non-Facility Representative
position at higher GS or ES level
or a supervisory position; Lateral -
Takes non-Facility Representative
position at same GS or ES level;
Retirement - Leaves DOE for
retirement; Resignation - Leaves
DOE other than retirement.]
N/A
TRAINING AND QUALIFICATION
TYPE INDICATOR NAME HOW TO CALCULATE GOAL
DOE-
wide
% of Facility Representatives
Core Qualified (see Section 3
Definition)
Number of Facility
Representatives Core Qualified
Number of Facility
Representatives
None specified
DOE-
wide
% of Facility Representatives
Interim Qualified (if
applicable; see Sections 3
and 5.5.3 for description)
Number of Facility
Representatives Interim Qualified
Number of Facility
Representatives
None specified
DOE-
wide
% of Facility Representatives
Fully Qualified
Number of Fully Qualified Facility
Representatives
Number of Facility
Representatives
Greater than 80%
DOE-STD-1063-2006
Appendix A
A-3
FACILITY REPRESENTATIVE PROGRAM ACCOMPLISHMENTS
TYPE INDICATOR NAME INFORMATION TO PROVIDE GOAL
DOE-
wide
Accomplishments
Any accomplishments of note
during the quarter, including
examples where safety and/or
facility mission accomplishment is
enhanced due to Facility
Representative interaction,
improvements in site Facility Rep
programs, hiring new Facility Reps,
etc.
None specified
FULFILLING THE FACILITY REPRESENTATIVE ROLE
TYPE INDICATOR NAME HOW TO CALCULATE GOAL
DOE-
wide
Facility Representative Time
Spent in the Plant/Field (Note
1)
Overtime and compensation
time hours count in both the
numerator and denominator
For Facility Representatives who
are at least Interim Qualified, the
number of hours spent in the
plant/ field this quarter (See Page
A-4 Column 1)
Number of available work hours
this quarter (Note 1)
Section 25
[Denominator only includes
number of hours expected by
DOE-STD-1063-2006, if the
Facility Representative is a part-
time Facility Representative.]
Greater than 40%
DOE-
wide
Facility Representative Time
Spent Performing Contractor
Oversight (Note 1)
Overtime and compensation
time hours count in both
numerator and denominator
For Facility Representatives who
are at least Interim Qualified, the
number of hours spent performing
contractor oversight this quarter
(See Page A-4 Column 2)
Number of available work hours
this quarter (Note 1)
[Denominator only includes
number of hours expected by
DOE-STD-1063-2006, if the
Facility Representative is a part-
time Facility Representative.]
Greater than 65%
Note 1 - Number of available work hours this quarter equals the actual
number of hours a Facility Representative works in a calendar quarter, including
overtime hours. It does not include leave time (sick, annual, or other) or
holidays. It also does not include special assignments (e.g., source evaluation
boards, accident investigations at another site, details to different offices) that are
greater than one week in length and are approved by the Field Element
Manager. For additional guidance on how to calculate these percentages, see
page A-4.
DOE-STD-1063-2006
Appendix A
A-4
Additional Guidance on Computing Facility Representative
Time Spent Performance Indicators
Activities that Count as Time
Spent in the Plant/Field
COLUMN 1
Goal: Greater than 40%
Activities that Count as Time Spent
Performing Contractor Oversight *
COLUMN 2
Goal: Greater than 65%
Activities That Should Not
Be Counted in Numerator
COLUMN 3
Plant walkthroughs/walkdowns Field time activities from Column 1
included
Surveillances Researching requirements
Assessments of the contractor Occurrence report reviews
Observing & participating in
critiques
Issues tracking and trending
Verifying completion of corrective
actions in the field or with the
contractor
Supporting facility related programmatic
needs and special projects
Observing operator activities and
maintenance actions
Reviewing DSAs, SERs, ABs, and other
safety documentation at desk
Training (mandatory
refresher, Regulatory,
continuing, facility access,
requalification, etc.)
authorized by DOE
management as being
pertinent for performing
Facility Representative and
Federal Employee duties.
Reviewing contractor documents
and procedures at the job site
Reviewing contractor documents and
procedures at desk
Non facility-related special
projects
Facility grounds and property tours Attending facility meetings Administrative/Collateral
duties
Completing facility condition
assessments
Communications involving issues
requiring DOE oversight
Commute time between facilities or
driving tours within facility
Discussions of actions required for
addressing issues
Attending contractor pre-job
briefings or other facility activity
briefings
Commute time between oversight
activities
Plan of the day/Plan of the week
meetings
Briefing Management on facility issues
Shift turnovers Providing feedback to the contractor
Response to facility/lab events PAAA corrective action validations
Observing or participating in facility
drills or lab exercises
Preparing reports for activities in Column
1
Emergency Operations Center
assignments
Performing facility review activities
(e.g., ISMS verification, ORR, RA)
in a facility at the Facility Rep’s site
Section 26
* Includes all activities under Time Spent in Plant/Field in addition to this column. Field office personnel
should exercise judgment as to whether portions of a particular activity should be counted under Time
Spent in the Plant/Field or Time Spent Performing Contractor Oversight. For example, if PAAA corrective
action validation occurs in the facility, it should be counted as Time Spent in the Plant/Field.
DOE-STD-1063-2006
Appendix A
A-5
EXAMPLE REPORT - RED RUN Site
Performance Indicators for First Quarter CY2006
(January 2006 through March 2006)
Submitted April 30, 2006
STAFFING
TYPE * INDICATOR NAME INDICATOR VALUE DOE GOAL
DOE-wide Staffing level (%) 90% [9 of 10] 100%
DOE-wide Attrition 1 - Promotion N/A
TRAINING AND QUALIFICATION
TYPE INDICATOR NAME INDICATOR VALUE DOE GOAL
DOE-wide % of Facility
Representatives Core
Qualified
100% [9 of 9] None specified
DOE-wide % of Facility
Representatives Interim
Qualified
100% [9 of 9] None specified
DOE-wide % of Facility
Representatives Fully
Qualified
78% [7 of 9] Greater than 80%
FACILITY REPRESENTATIVE PROGRAM ACCOMPLISHMENTS
TYPE INDICATOR NAME INFORMATION DOE GOAL
DOE-wide Accomplishments • Facility Representatives at the nuclear fuel
facility recognized the potential for a high
airborne radioactivity condition being caused
by leak-by of a contaminated system
pressure relief valve. Air samples conducted
as a result of the Facility Representatives’
questions confirmed a high airborne
condition.
• A Facility Representative observed a worker
who was working approximately 21 feet
above a concrete slab without using fall
protection equipment. The worker
immediately began using the safety
equipment and the safety manager briefed
workers on the incident.
None specified
FULFILLING THE FACILITY REPRESENTATIVE ROLE
TYPE INDICATOR NAME INDICATOR VALUE GOAL
DOE-wide Facility Representative
Time Spent in the
Plant/Field
55% Greater than 40%
DOE-wide Facility Representative
Time Spent Performing
Contractor Oversight
70%
Greater than 65%
* All samples in this table are DOE-wide indicators. Field elements may provide
additional site-specific performance indicators.
DOE-STD-1063-2006
Appendix B
B-1
FACILITY REPRESENTATIVE PROGRAM ASSESSMENT GUIDE
The Department of Energy has implemented its Facility Representative Program,
and is looking to continuously improve the program’s effectiveness DOE-wide.
An effective Facility Representative Program has many elements, as described in
this Standard. These elements are intended to yield a program that provides
DOE facilities with well-trained Facility Representatives, who spend appropriate
amounts of time in their facilities, and can work effectively with their contractor
management counterparts. The program, to be effective, needs the functional
support of management. To maintain the continued support of DOE
management, the Facility Representative program needs to demonstrate its
continued performance and effectiveness, which is to be assessed periodically
using this guide. Any assessment of a Facility Representative Program should
determine the extent to which the objectives below are being met, and provide
recommendations on improving the program’s effectiveness. Assessment
criteria, review and approach documents (CRADs) for the Facility Representative
Program are contained in DOE M 226.1 (draft). The Assessment Lines of
Question in this appendix support those CRADs.
Objectives:
Section 27
1) Well-trained, qualified Facility Representatives.
2) Adequate coverage for DOE facilities.
3) Facility Representatives provide effective oversight of facilities.
4) Adequate functional support from the Field Element Management.
5) Performance assessment and feedback program in place.
Purpose:
The purpose of this guide is to provide the Department with a consistent set of
guidelines to assess the effectiveness of Facility Representative Programs.
Scope:
This guide is provided for use by DOE HQ and Field Elements to assess the
effectiveness of their Facility Representative Programs as described in DOE
STD-1063-2006.
References:
The following references should be used in conjunction with this guide:
• General Technical Base Qualification Standard, DOE-STD-1146-2001
• Facility Representative Functional Area Qualification Standard, DOE-STD-
1151-2002
DOE-STD-1063-2006
Appendix B
B-2
• Applicable Field Element site-, and facility-specific qualification standards
• Applicable Field Element site-, and facility-specific program implementing
documents
• Applicable Field Element Facility Representative Program Performance
Indicators
I. ASSESSMENT LINES OF QUESTION
The following Lines of Question examine the strength and maturity of the Field
Element’s Facility Representative Program and the effectiveness of its Facility
Representatives by assessing performance at meeting the five objectives of the
Facility Representative Program. The Lines of Questions are based on program
requirements (i.e., “shall” statements), recommended practices (i.e., “should”
statements), and suggested practices (i.e., “may” statements). Not all Lines of
Questions are based on “shall” requirements and may not apply to all Facility
Representative programs.
1. Well-trained, qualified Facility Representatives.
• Do training records show that Facility Representatives, who are listed as
qualified, have the proper education and experience, and that they have
completed all qualification requirements as specified in General Technical
Base Qualification Standard (DOE-STD-1146-2001), Facility Representative
Functional Area Qualification Standard (DOE-STD-1151-2002), and local
directives? [Sections 5.4 and 5.5 ]
• Do Field Element Managers qualify Facility Representatives? [Section 5.5]
• Do the training records show that Facility Representatives complete all
requalification requirements at the periodicity specified in the program
directive? [Section 5.5.6]
• Are the qualifying officials involved in the qualification of Facility
Representatives formally identified? [Sections 5.5.1 and 5.5.8 ]
• Is the process used to ensure that qualified Facility Representatives maintain
or regain proficiency formally defined and effective? [Section 5.5.7]
• If Facility Representatives have failed to qualify or requalify within the time
allowed, what actions were taken by the responsible Field Element Manager?
[Section 5.5.8.d ]
• Does the examination process challenge the candidate sufficiently to verify
the proper level of knowledge of all qualification areas and facilities? Do they
test the Facility Representative’s technical understanding of facility
processes, judgment and decision-making abilities, and ability to
communicate expectations to the contractor? [Section 5.5.8]
• How well does the Facility Representative understand his/her roles and
responsibilities under the Field Element’s Facility Representative Program?
[Section 4.1]
DOE-STD-1063-2006
Appendix B
Section 28
B-3
• How well does Facility Representative continuing training provide hazard
related and activity related information to Facility Representatives? [Appendix
D]
2. Adequate coverage for DOE facilities.
• Is the Facility Representative staffing analysis performed in accordance with
this standard and are Facility Representatives staffed to the indicated level?
[Sections 5.1 and Appendix C]
• Are sufficient numbers of Facility Representative candidates undergoing
qualification to fill known or projected Facility Representative vacancies? If
not, what is being done to correct the situation? [Section 5.1]
• How long have current Facility Representative vacancies existed? [Section
5.1]
• What is the trend of the reported time spent in the field and time performing
oversight? [Section 5.8.1 and Appendix A]
• What methods are used by the Field Element Manager to ensure that
adequate facility coverage is maintained by qualified Facility Representative
during periods of leave? [Section 5.1]
3. Facility Representatives provide effective oversight of facilities.
• Has Facility Representative unencumbered access and “Stop Work” authority
in their assigned facilities been adequately implemented? [Section 4.1.7]
• Has “Stop Work” authority been exercised? Was it appropriate? Was it
effective? Are there occasions when it was appropriate for Facility
Representatives to exercise “Stop Work” authority, but it was not used?
[Section 4.1.7]
• What is the effectiveness of the Facility Representatives as verified by
observing selected qualified personnel who are monitoring training,
operations, or maintenance evolutions? [Section 4.1]
• Based on a sample of occurrence reports, are Facility Representative reviews
of the occurrence reports accomplished in a timely manner while ensuring
that the root cause has been determined and effective action proposed?
[DOE M 231.1-2 Section 5.6.c]
• Do Facility Representatives accomplish facility assessments, surveillances
and audits as scheduled and are the findings meaningful and consistent with
facility performance? [Sections 4.1 and 5.2]
• Based on a sample of deficiencies identified by Facility Representatives
during reviews, have Facility Representatives evaluated the overall
effectiveness of the operating contractor in implementing corrective actions?
[Sections 4.1.5 and 4.1.10]
DOE-STD-1063-2006
Appendix B
B-4
• Has the Field Element Manager implemented a process to track identified
issues or discrepancies to satisfactory closure? [Sections 4.1.5, 4.1.10, and
4.2.4]
• How adequate is the documentation of Facility Representative activities (e.g.,
reports, log keeping)? [Section 4.1.10]
• How are Facility Representative findings reported (formally and informally) to
the contractor? Are the reports provided to the contractor consistent with the
information recorded by the Facility Representatives? How clear is the
process of reporting findings to the contractor? [Section 4.1.10]
• Does the Facility Representative have access to and communicate effectively
with all levels of contractor management? [Section 4.1.10]
• Are the Facility Representative interactions with the operating contractor
effective in meeting the shared goals of safe and efficient facility operations?
[Section 4.1.10]
4. Adequate functional support from the Field Element Management.
• What are the reasons for any Facility Representative attrition? Are Facility
Section 29
Representative’s leaving for promotions, laterals, downsizing? Have steps
been taken to counter excessive attrition? [Section 5.1 and Appendix A]
• What steps has management taken to ensure that the Facility Representative
positions are career enhancing? Are there senior or supervisory Facility
Representative opportunities? [Section 4.2.4]
• What continuing training, professional certifications, graduate studies, or
similar development activities are actively supported? [Section 5.7]
• What role does Field Element Management have in the qualification process?
[Sections 4.2.4 and 5.5]
• Does management provide the resources necessary to qualify Facility
Representatives within a defined schedule? [DOEM 426.1-1A Chapter III,
Paragraph 4.b]
• How does line management support the actions taken by the Facility
Representatives at the respective facilities? [Section 4.1.8]
• What is interface relationship between the Facility Representatives and each
level of DOE line management? [Section 4.1.8]
• Do Facility Representatives periodically meet with senior line managers within
the field element to provide information related to the assigned facilities?
[Section 4.2.4]
• How does DOE line management track and follow up on issues raised by the
Facility Representatives? [Section 4.1.10]
• What process does DOE management use to address differing professional
opinions and has it been used effectively? [Section 5.9]
• What local processes exist to allow Facility Representatives access to Field
Element technical expertise regarding contractor issues? [Section 4.1.9]
DOE-STD-1063-2006
Appendix B
B-5
• What Performance Indicator data is used to provide indication of the Facility
Representative program status? What trending and analysis is done on
Performance Indicator data? How is this information used? [Section 5.8.1
and Appendix A]
• What incentive programs are in place and used effectively for the Facility
Representative position? [Section 5.7.6]
• Do these programs make the Facility Representative position desirable and
career enhancing? [Section 5.7.6]
5. Performance assessment and feedback program in place.
• How often does the Field Element conduct self-assessments of the entire
Facility Representative program? [Section 5.8.2]
• Are peer reviews incorporated into the self-assessment process? [Section
5.8.3]
• How does the Cognizant Secretarial Officer ensure that program performance
assessments are accomplished, and any indicated corrective actions are
completed? Mechanisms could include providing a representative to
participate in assessments. [Section 4.2.3]
• How well does the self-assessment program ensure that the evaluators have
adequate knowledge and experience to conduct meaningful reviews? Based
on self-assessment reports, have adequate reviews been conducted to be
able to properly evaluate the assigned area of assessment and have the self-
assessments generated meaningful recommendations for improvement and
corrective actions? [Section 5.8.2 and Appendix B]
• Did the Field Element Manager pursue improvements to the Facility
Representative program resulting from self-assessments of the program?
[Sections 4.2.4 and 5.8]
• How are the Facility Representatives kept informed on changes to their
facilities and their operating practices? [Section 5.4.4 and 5.5.6 ]
• How are lessons learned from facility events disseminated to Facility
Representatives? [Section 5.5.6 and Appendix D]
Section 30
• How are applicable lessons learned from facility events at other DOE facilities
sought and disseminated to Facility Representatives? [Sections 5.8.4 and
Appendix D]
II. APPROACH
The approach to be used in performing the Facility Representative Program
assessment is expected to vary between Field Elements. In order to obtain a
valuable assessment of the program, the following methodology is presented.
Documentation. Much information can be determined in advance of the
assessment by careful review of program documentation. This can include:
DOE-STD-1063-2006
Appendix B
B-6
1. Program directive(s) and procedure(s)
2. Performance Indicators (DOE-wide and locally generated)
3. Qualification tracking data
4. Significant Occurrence Reports
5. Performance Assessments including the Facility Representative Program
Self-Assessment
6. Training records (including continuing training)
7. Qualification records
8. Facility Representative logs
9. Facility Representative reports
10. Management tracking system for Facility-Representative-reported issues
11. Written and oral examination question banks
Interviews. By discussing the program with its participants, a determination can
be made about program performance “on paper” as opposed to “in reality.”
Consideration should be given to interviewing:
1. Facility Representative Program sponsors
2. Facility Representatives
3. Facility Representative supervisors
4. Line managers
5. Contractor facility managers
6. Technical Expertise support (health physics, explosive safety, etc)
Walkthroughs. Much information can be determined by performing walkthroughs
with the Facility Representatives. Walkthroughs can provide indication of:
1. Level of Facility Representative qualification
2. Actual practices of the facility
3. Interactions with contractor personnel
4. Log-keeping and reporting practices
5. Corrective action verification
Other methods. The preceding list of methods is for example purposes.
Additional methods exist which may help in assessing program performance and
should be used as appropriate.
III. REPORT
This section contains the report format which can be used to document these
reviews of Facility Representative Programs. The report should be in narrative
format and include the following:
DOE-STD-1063-2006
Appendix B
B-7
Report header:
Date of report
Facility Representative Program Review
Field Organization
Date(s) of review
Summary:
Includes a brief synopsis of the program assessment including activities
observed, personnel interviewed (by position), and documents reviewed. Each
section of the report should be evaluated as adequate, marginal, or
unsatisfactory. An overall grade for the assessment (satisfactory or
unsatisfactory) should be assigned. The report should specifically identify
excellent practices worth sharing as well as significant, or key weaknesses
noted. A rationale should be provided for the grade given, based on current
program status, progress made, and achievement of the program objectives.
Discussion:
For each of the listed program objectives, provide a report of current status,
progress made in this area, grade assigned, and recommendations for
improvement.
1. Well-trained, qualified Facility Representatives.
2. Adequate coverage for DOE facilities.
3. Facility Representatives provide effective oversight of facilities.
4. Adequate functional support from the Field Element Management.
5. Performance assessment and feedback program in place.
Section 31
DOE-STD-1063-2006
Appendix C
C-1
PROCESS TO DETERMINE FACILITY REPRESENTATIVE STAFFING
Overview
The steps below describe an analytical process to determine Facility
Representative staffing for all hazardous facilities at a site. This method provides
a technical approach to determine the appropriate amount of Facility
Representative oversight necessary for a facility given its hazard level,
operational activity and complexity, and programmatic importance. This staffing
approach is also designed to provide DOE with a common human capital
strategy approach such that the DOE enterprise can objectively analyze,
allocate, budget, and justify Facility Representative resources and endstrength
throughout the DOE Complex.
Methodology
The following elements shall be included in each site analysis:
1. A relative ranking of facilities based on hazards or risks present to the
public, worker, and/or environment.
2. A method for determining Facility Representative coverage (e.g.,
continual, frequent, occasional, etc.) based on facility categorization and
adjusted for other factors identified in DOE-STD-1063-2006 such as
facility size, operations complexity, hazards and risks, etc.
3. A determination of Facility Representative Full Time Equivalent (FTE)
requirements based on coverage assigned and adjusted to address
factors considered in Step 2 above.
4. A determination of actual staffing based on Facility Representative FTE
requirements adjusted to account for actual staff time available to support
the Facility Representative function when competing activities such as
collateral duties, leave, training, etc. are considered.
Procedures
Procedures for conducting a Facility Representative staffing analysis follow each
table. Tables 1-4 describe the process to determine Facility Representative FTE
levels for facilities or groups of facilities. Tables 5-6 represent two methods of
determining actual staffing levels necessary to meet the FTE level, taking into
account the duties, responsibilities, leave, and training typical of Facility
Representatives at each site.
DOE-STD-1063-2006
Appendix C
C-2
Table 1 – Facility Hazard Value
(Facility 1, 2, and 3 are provided as examples)
Rad.
Exp. Criticality Biological Hazard.
Chem. Fire Electrical Cryogens High
Pressure
Hoisting
& Rigging Explosives Other
Facility
or
Group of
Facilities pu
bl
ic
w
or
ke
r
en
vi
ro
nm
en
t
pu
bl
ic
w
or
ke
r
en
vi
ro
nm
en
t
pu
bl
ic
w
or
ke
r
en
vi
ro
nm
en
t
pu
bl
ic
w
or
ke
r
en
vi
ro
nm
en
t
pu
bl
ic
w
or
ke
r
en
vi
ro
nm
en
t
pu
bl
ic
w
or
ke
r
en
vi
ro
nm
en
t
pu
bl
ic
w
or
ke
r
en
vi
ro
nm
en
t
pu
bl
ic
w
or
ke
r
en
vi
ro
nm
en
t
pu
bl
ic
w
or
ke
r
en
vi
ro
nm
en
t
pu
bl
ic
w
or
ke
r
en
vi
ro
nm
en
t
pu
bl
ic
w
or
ke
r
en
vi
ro
nm
en
t
Facility
Hazard
Value
Facility 1 2 3 1 0 2 0 0 0 0 0 1 1 1 2 0 0 2 0 0 0 0 0 1 0 0 2 0 1 1 0 0 0 0 21
Facility 2 0 2 1 0 1 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 0 0 1 0 0 1 0 0 0 0 0 0 0 10
Facility 3 0 1 0 0 0 0 2 3 2 1 2 1 0 1 0 0 1 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 15
Procedure to Complete Table 1 – Facility Hazard Value
1. List all hazardous facilities or groups of facilities in the left column.
2. List types of hazards across the top row. These should include the hazards within a facility, such as radiation
exposure, criticality, hazardous chemicals, electrical, cryogens, lasers, explosives, construction or D&D, hoisting
& rigging, and other hazards in the facility.
Section 32
3. Evaluate each hazard at each facility based on the relative magnitude of the hazard to the public, worker, and
environment. The evaluation should include the complete spectrum of hazards in the facility that could expose
members of the public, onsite workers, facility workers and the environment to hazardous materials. Th e ranking
system used in this example is as follows: high hazard – 3, moderate hazard – 2, low hazard – 1, no hazard - 0.
Definitions for hazard evaluation are as follows:
• High – Potential for onsite and offsite impacts to large numbers of persons or for major impacts to the
environment.
• Moderate – Potential onsite impacts to people or the environment, but at most only minor offsite impacts.
• Low – Potential for minor onsite and negligible offsite impacts to people and the environment.
4. Sum the facility hazards across each row to determine the Facility Hazard Value.
5. Enter these values in Table 2, column b.
DOE-STD-1063-2006
Appendix C
C-3
Table 2 - Determination of Facility Coverage Priority Ranking
(Facility 1, 2, and 3 are provided as examples)
Facility or
Group of
Facilities
Facility Hazard
Value
(From Table 1)
Facility
Size
Material
Condition
Operations
Complexity
Programmatic
Importance
Operational
Rigor
Coverage
Priority
Ranking*
a b c d e f g h
Facility 1 21 1.25 1 1.25 1 1 33
Facility 2 10 1 1 1 1 1.25 13
Facility 3 15 0.75 0.75 1 1.25 1 11
* Facility Representative coverage is optional for non-nuclear facilities with a Coverage Priority Ranking below 15.
Procedure to Complete Table 2 – Determination of Facility Coverage Priority Ranking
The Coverage Priority Ranking is an adjustment to the Facility Hazard Value based on factors such as facility size,
material condition, operations complexity, programmatic importance, and operational rigor. The Coverage Priority
Ranking is calculated by multiplying facility hazard value by the modifying factors (h=b*c*d*e*f*g). Other factors
appropriate for a particular site or facility may also be used. The Coverage Priority Ranking determines the priority of
assigning Facility Representatives to a facility or group of facilities based on the hazards present as modified by these
factors. Sort facilities by Coverage Priority Ranking from highest to lowest. The modifying factors are defined as
follows:
Facility Size (c): 0.75 – Operations areas less than 10,000 square feet
1.00 – Operations areas between 10,000 square feet and 100,000 square feet
1.25 – Operations areas greater than 100,000 square feet
Material
Condition (d): 0.75 – Configuration management program is mature, as -built drawings are reasonably accurate, material
management/pedigree programs are in place, replacement parts for safety systems are available,
safety systems are reliable, condition similar to what one would expect for a new or well maintained
facility
1.00 – Between .75 and 1.25
1.25 – As-built drawings are unavailable or very out-of-date, replacement parts for safety systems are hard
to get or unavailable, safety system reliability is degraded, condition similar to what one would
expect for an old or poorly maintained facility
Operations
Complexity (e): 0.75 – Majority of the following conditions are present: One primary program/function, less than 250
employees, single chain-of-command, modest level of expertise and training required to operate
1.00 – Between .75 and 1.25
1.25 – Majority of the following conditions are present: Multiple distinct programs/functions, many different
Section 33
activities/disciplines, many different tenants or chains -of-command, greater than 500 employees,
high level of expertise and training required to operate
Programmatic
Importance (f): 0.75 – Unplanned outages for up to 30 days will not negatively affect DOE Strategic Plan deliverables or
objectives
1.00 – Limited impact on the DOE Strategic Plan deliverables or objectives as a result of unplanned
outages for up to 30 days
1.25 – Significant impact on DOE Strategic Plan deliverables or objectives as a result of unplanned
outages exceeding 30 days
Operational
Rigor (g): 0.75 – Well implemented Conduct of Operations Programs. Within the last year, zero of the following
significant events/accidents: radiation over-exposures or uptakes, injuries requiring hospitalization,
lockout/tagout violations, or environmental releases. Within the last year, zero TSR/AB violations.
Contractor integrated management systems are verified mature.
1.00 – Between .75 and 1.25
1.25 – Conduct of Operations is poorly implemented. Within the last year, two or more of the following
significant events/accidents: radiation over-exposures or uptakes, injuries requiring hospitalization,
lockout/tagout violations, or environmental releases. Within the last year, more than three AB/TSR
violations. Contractor integrated management systems not mature.
DOE-STD-1063-2006
Appendix C
C-4
Table 3 - Determination of Facility Representative Coverage
(Facility 1, 2, and 3 provided as examples)
Facility or
Groups of
Facilities
Coverage
Priority
Ranking*
(from Table 2
column h)
Facility
Categoriza
tion
Facility
Activity
Level
Recommended
Base Coverage
Level
Initial FTE
Coverage
Level
Adjusted
FTE
Coverage
Level
Recommended
FTE Coverage
Level
Percentage
of Time
Available to
Provide FR
Coverage
(From Table
5)
Final FTE
Coverage
Level
a h i j k l m n o p
Facility 1 33
Nuclear
Haz Cat 2 High
Frequent
(0.50 – 1.00) 1.00 1.25 1.50 0.73 2.06
Facility 2 13
Nuclear
Haz Cat 3 High
Intermittent
(0.25 – 0.50) 0.50 0.50 0.50 0.73 0.68
Facility 3 11 Biosafety
Level 3
Medium Intermittent
(0.25 – 0.50)
0.25 0.25 0.25 0.73 0.34
* Facility Representative coverage is optional for non-nuclear facilities with a Coverage
Priority Ranking below 15. Total 2.25 3.08
Total FRs Onboard 2.0
Explanation of Difference
Hiring action in
progress to add 1 FR.
Procedure to Complete Table 3 – Determination of Facility Representative Coverage
1. List each facility or groups of facilities for which Facility Representative coverage is desired, according to the facility’s
Coverage Priority Ranking (columns a, h). Facility Representative coverage is optional for non-nuclear facilities with
a Coverage Priority Ranking below 15. This allows site offices flexibility to perform oversight on these facilities using
personnel other than Facility Representatives.
2. Determine the Facility Categorization. Use Table 4, Recommended Facility Representative Base Coverage Levels,
to determine the Facility Categorization and enter into column i.
3. Determine Facility Activity Level. The activity level definitions are:
HIGH: Facilities that daily to weekly involve activities with one or more hazards.
MEDIUM: Facilities that weekly to monthly involve activities with one or more hazards.
LOW: Facilities that monthly to quarterly involve activities with one or more hazards.
Section 34
4. Recommended Base Coverage Level (column k). Use Table 4 to determine the Recommended Base Coverage
Level for a facility (Continual, Frequent, Occasional, etc.) based on the Facility Categorization and Facility Activity
Level and enter in column k. The definitions for the Recommended Base Coverage Level are:
CONTINUAL: The Facility Representative is present daily. This coverage may require the complete attention of
one or more individuals and may require back shift, weekend, or 24-hour coverage. If the
normally-assigned Facility Representative is gone for one week or longer, the Field Element
Manager should name a temporary replacement and establish an appropriate coverage
schedule.
FREQUENT: The Facility Representative is present approximately half of the time (i.e., about 2-4 days per
week). One person can cover multiple facilities. If the normally-assigned Facility Representative
DOE-STD-1063-2006
Appendix C
C-5
is gone for two weeks or longer, the Field Element Manager should name a temporary
replacement and establish an appropriate coverage schedule.
INTERMITTENT: The Facility Representative is present at least one day per week. One person can cover several
such facilities.
OCCASSIONAL: The Facility Representative visits the facility 12-24 days a year.
SELDOM: The Facility Representative visits the facility 6-12 days a year.
The Recommended Base Coverage Levels correspond to the following Recommended FTE Levels:
Recommended Base Coverage
Level
Recommended FTE
Level
CONTINUAL > 1.00
FREQUENT 0.50 – 1.00
INTERMITTENT 0.25 – 0.50
OCCASIONAL 0.10 – 0.25
SELDOM < 0.10
5. Initial FTE Coverage Level (column l). Determine the appropriate initial FTE coverage level from the recommended
FTE Level and place in column 1.
6. Adjusted FTE Coverage Level (column m). Multiply the FTE Coverage Level (column l) by an Adjustment Factor in
the table below, and put the result in column m. This ensures that facilities with the highest hazards, operational
activity, complexity, and of greatest programmatic importance receive higher coverage. The Adjustment Factors are:
Coverage Priority Ranking Value Adjustment Factor
> 100 2.00
50 – 99 1.50
25 – 49 1.25
< 25 No Adjustment
7. Recommended FTE Coverage Level (column n). Following establishment of the Adjusted FTE Coverage Level
(column m) for each facility, the Field Element Manager (FEM) may further adjust the level of coverage. This
adjustment should take into consideration factors such as those listed below and be based on the FEM’s judgment
of the contractor’s operational performance and the priority of coverage identified in column h:
• Facility operations involving multiple shifts
• History of contractor performance for similar activities
• Potential for DOE or public interest
• The risks to successful mission accomplishment
• Financial risks
• Complexity of the facility and facility operations
• Hazardous work environments for workers
• Age, maintenance condition, and level of uncertainty of the facility
• Anticipated changes in operational status of facility
• Number of significant accidents/incidents on site
• Amount of other DOE technical facility oversight
• Facility configuration changes (like test facilities, for example)
Section 35
8. The next step is to adjust the Recommended FTE Coverage Level to account for additional duties assigned to
Facility Representatives, as well as other competing activities. This can be done by using Table 5 or Table 6. Table
5 is used if sites can accurately estimate other activities for the group of Facilities Representatives at the site. Table
6 is used if Facility Representatives have different collateral duties from each other which would make using Table 5
impractical. Both Table 5 and Table 6 represent workload analyses to ensure that the Facility Representative
coverage assigned is achievable given the other duties assigned to the Facility Representatives.
DOE-STD-1063-2006
Appendix C
C-6
Table 4 – Recommended Facility Representative Base Coverage Levels
Facility Activity Level
Chemical Hazards
Class1
Biological
Hazard
Level 2
Nuclear Hazard
Categorization 3
Other
Hazardous &
Unique
Facilities 4 High Medium Low
Biosafety
Level 4
Category 1 Hazard Continual Frequent Intermittent
Facilities with regulated
hazardous material requiring a
Risk Management Plan
AND
The potential for ERPG-2 levels
or TEEL-2 for off-site
Biosafety
Level 3
Category 2 Hazard
Facilities that
pose a significant
risk offsite
Frequent Intermittent Occasional
Facilities with regulated
hazardous material requiring a
Risk Management Plan
OR
The potential for ERPG-2 levels
or TEEL-2 for collocated worker
(100M)
Biosafety
Level 2 Category 3 Hazard
Facilities that
pose a significant
risk to on-site
workers
Intermittent Occasional Seldom
Inventories of flammable
materials and reactive
compounds exceeding threshold
quantities in 29 CFR 1910.119
Radiological Facilities
Facilities that
have a critical
mission and
require additional
oversight
Occasional Seldom
Coverage
Optional
Notes:
1. Chemical hazard classes are established by OSHA and EPA. Regulated Toxic and Regulated Flammable
Substances and their Threshold Quantities are listed in 40 CFR Part 68.130. Extremely Hazardous
Substances and Threshold Planning Quantities are listed in 40 CFR Part 355, Appendices A and B. Process
Safety Management chemicals are listed in 29 CFR 1910.119.
2. Biological hazard levels are defined in Biosafety in Microbiological and Biomedical Laboratories , U.S.
Department of Health and Human Services Centers for Disease Control and Prevention and National
Institutes of Health Fourth Edition, May 1999
3. Nuclear hazard categorization is from DOE-STD-1027-92, (CH-1) Hazard Categorization and Accident
Analysis Techniques for Compliance with DOE Order 5480.23, Nuclear Safety Analysis Reports
4. Other Hazardous & Unique Facilities are identified by the Field Element Manager that could pose a
significant risk to public or worker safety or crucial mission facilities that require Facility Representative
oversight. Consideration could include poor operational or safety performance, special needs, and significant
public concern.
DOE-STD-1063-2006
Appendix C
C-7
Table 5 – Example Facility Representative Available Time for Coverage, Generic Analysis
FR Activity that does not provide
oversight of his/her assigned facility
or increases facility oversight time*
Average Time required to perform
identified activity across the FR
Program being analyzed
Hours required to perform
identified activity annually
Annual Leave 6 hours per pay period -156
Sick Leave 1 week per year -40
Administrative Duties 10% of time -208
Training 3 weeks per year -120
Section 36
Collateral Duties 3 hours per week at work -132
Federal Holidays 10 Holidays -80
Special Assignments 1 week -40
Overtime 10% +208
Available Time Adjustment -568
Percentage of Time Available to provide FR Coverage (2080 + Available Time Adjustment /
2080)
0.73
Staff Required to meet FR coverage required on Table 3 and additional activities identified on
this table (FTE Required from Table 3 / Percentage of time Available) 2.25/0.73 = 3.08
* Activities that reduce FR coverage are negative, activities that increase FR coverage (overtime, staff detailed to provide
backup oversight, etc.) are positive
Procedure to Complete Table 5 – Facility Representative Available Time for Coverage, Generic Analysis
This method identifies a uniform factor that can be applied to the Facility Representative Coverage Required (FTE) number
derived in Table 3 (column n) to determine the actual number of staff required to meet the minimum coverage requirement
when activities that compete with FR duties are considered. Attachment 1 lists some of the activities that may need to be
considered; sites should develop the list applicable to their Facility Representative Program. This method works well when
the non-FR activities completed by Facility Representatives are relatively uniform across the organization.
1. Identify activities performed by Facility Representatives in addition to the evaluated FR duties.
2. Determine the average amount of time spent performing those activities across the FR Program, either as a percentage
of work time or on an annual basis.
3. Calculate the total percentage of time available to perform FR functions.
4. Divide the total number in Table 3 column n by the percentage of time spent performing non-Facility Representative
activities to determine the staffing required to achieve the effective Facility Representative staff required.
5. For Facility Representatives in training, increase training time from 120 hrs per year or 7% to an appropriate value (e.g.,
approximately 25% or 400 hrs per year).
DOE-STD-1063-2006
Appendix C
C-8
Table 6 - Facility Representative Available Time for Coverage, Assignment Specific Analysis
(Facility 1, 2, and 3 provided as examples)
Staff
Assigne
d Facility
Coverage
Groupings
Total
Hours
Availabl
e
Collateral Duty Assignments
and Estimated Time
Commitments [hours/year]
Leave,
Admin,
Training
Time
[hours/year]
Effective
Facility
Coverage
[Hours]
Effective
Facility
Coverage
[FTE]
Recommended
FTE Coverage
Level
Is Effective
Coverage
Acceptable?
Yes/No
(If no, describe
additional
measures)
FR A
FR B
FR C
SSO Program
Coordination
DOE RA
Duty Officer Program
Management
Radiological Assistant
Program
Duty Officer
DOE Accident
Investigation
200
80
75
40
32
160
525
525
525
Facility 1
6240 587 1575 4078 2.00 1.50 yes
FR D EEO/Special
Emphasis
Coordinator
Duty Officer
HQ Program Manager
Liaison
100
32
500
525
SSO coverage
will occur at
about 0.05 FTE
to make up the
oversight
difference. Need
to re-evaluate in
6 months for
effectiveness.
Facility 2
2080 632 525 923 0.44 0.50 no
FR E FR Training Manager
Duty Officer
Criticality Engineer
Overtime
500
32
250
-100
525 Facility 3
2080 682 525 873 0.42 0.25 yes
Procedure to Complete Table 6 – Facility Representative Available Time for Coverage, Assignment Specific
Analysis
Section 37
This method evaluates the actual staff time available for performing Facility Representative functions based on individual
Facility Representative assignments, and compares that number with the Table 3-derived Recommended FTE Level (Table
3, column n) to determine if staffing is adequate or should be modified. This method works well when the non-Facility
Representative activity time requirements vary considerably between Facility Representatives.
1. List facility/facility groupings with the Facility Representatives/assignments.
2. Sum the total man-hours assigned; on an annual basis this is typically 2080 hours times the number of Facility
Representatives assigned.
3. List the collateral duty assignments, leave, special assignments, and other activities that are not Facility Representative
activities that will be completed by the assigned Facility Representatives.
4. Sum the total man-hours spent performing these activities
5. For Facility Representatives in training, increase training time from 120 hrs per year or 7% to an appropriate value (e.g.,
approximately 25% or 400 hrs per year).
6. Subtract the total number of hours spent performing the non-Facility Representative activities from the total Facility
Representative hours assigned.
7. Divide the total available hours determined in the above step by 2080 to determine the effective FTE available to
perform Facility Representative duties.
8. Compare the effective FTE available to perform the Facility Representative duties with the Table 3-derived
Recommended FTE Level (Table 3, column n) to determine if staffing is adequate or should be modified.
DOE-STD-1063-2006
Appendix C
C-9
Attachment 1 - Examples of Activities that Facility Representatives May
Perform in Addition to Facility Representative Duties
* Serving on Readiness Review Teams and/or Accident Investigation Teams at a site other
than the Facility Representative’s normal site is considered a Special Assignment for the
purposes of this staffing analysis.
Examples:
1. Participation on a readiness review at a site different from the Facility
Representative’s assigned site is considered a competing activity; however, technical
support to a readiness review team or participation on a readiness review team at the
Facility Representative’s assigned site is not a competing activity and is considered
part of the Facility Representative’s assigned coverage duties.
2. Evaluating Occurrence Reports for the Facility Representative’s assigned facility is
part of the Facility Representative’s assigned coverage duties; however, managing
site-wide implementation of ORPS, performing as a subject area SME, developing
and evaluating site-wide performance of contract measures, process interpretations,
reengineering efforts, etc. are collateral duties beyond those expected for Facility
Representative facility coverage.
Activity Examples
ORPS process management
Conduct of Operations Implementation
Readiness Review Process
Collateral Duties
Duty Officer Program Management
Integrated Project Teams
Special Emphasis / EEO Program Site Rep
NNSA Duty Officer
Site Office Support
Radiological Assistance Program Team Leaders
Readiness Review Team Members at a Different Site*
Accident Investigation Team Members at a Different Site*
Special Contractor Project Partnering Team Members
NNSA Policy Teams
Contract Source Evaluation Board Support
Special Assignments
Management Support Teams
Continuing Training
Mandatory Training
Qualification/Requalification Training
Access Training
Section 38
Training
Personal Development Training
Time Keeping
Training Registration
Travel
Performance Indicator Tracking
Surveys
Personnel Activities
Document Reviews (RevCom, FRAM, internal policies)
Administrative Duties
E-mail management
Annual
Sick
Leave
Military
DOE-STD-1063-2006
Appendix D
D-1
CONTINUING TRAINING GUIDANCE
The purpose of this guidance is to provide a structured approach for providing
hazard- and activity-related information to Facility Representatives after
completing the qualification process established by DOE. Facility
Representatives should participate in the process described below so they keep
abreast of new or significant changes to site-specific hazards or activities. This
guidance was developed by NNSA personnel and incorporated into NNSA site
procedures, and is recommended for other sites as well. Site o ffices may use an
alternate approach provided the intent of the guidance is met. DOE-HDBK-1118-
99, Guide to Good Practices for Continuing Training, is a useful reference for
developing any continuing training procedure.
1. Identification of hazards
New or significant changes to hazards and activities that could have an impact on
safety should be identified as soon as possible , preferably prior to being present
in a facility, through a process established and endorsed by management. The
site process should ensure that appropriate subject matter experts review and
summarize the relevant information and provide that information to the manager
responsible for Facility Representative continuing training. The manager
responsible for Facility Representative training should determine the required
training (See 3. “Training”)
The following are examples of information that should be reviewed to identify new
or significantly changed site-specific hazards or activities:
a. Positive Unreviewed Safety Questions (USQs).
b. Annual updates to Documented Safety Analyses (DSAs).
c. New DSAs and associated Safety Evaluation Reports (SERs).
d. Justifications for Continuing Operation (JCOs).
e. Changes to Technical Safety Requirements (TSRs).
f. Authorization Agreement changes.
g. New or significantly changed processes that require Process
Hazards Analyses (PHAs) or equivalent documents.
h. Significant changes to emergency or abnormal operations
procedures.
i. Reviews associated with significant start-up or re-start activities
(e.g., Readiness Assessment / Operational Readiness Review,
Joint Nuclear Readiness Team, or Nuclear Explosive Safety Study).
j. Critical Decisions (e.g., CD-3)
k. Accident investigation reports
l. Changes to occurrence reporting requirements
DOE-STD-1063-2006
Appendix D
D-2
2. Analysis of hazards
New information should be evaluated to determine whether additional training is
necessary on significant new hazards or activities. A record of information
reviewed or considered for training should be maintained.
3. Training
Facility Representatives, Safety System Oversight or other appropriate Federal or
contractor personnel should conduct the training. The training should be
provided to all Facility Representatives and should be considered for other
appropriate subject matter experts.
Classroom training (lecture or seminar), structured self-study (using a lesson
plan, handout, or required reading), and walkdowns/tours are all examples of
acceptable training methods.
4. Revision
The current site -specific Facility Representative qualification standard(s) should
be reviewed to determine if it should be revised to incorporate new information.
If so, the revision should be performed in accordance with site procedures.
5. Documentation
All training provided should be documented, and attendance should be tracked to
verify that affected Facility Representative received training. Training records
should be sent to the site training office.
DOE-STD-1063-2006
CONCLUDING MATERIAL
Review Activities:
Headquarters Offices
NNSA
EH
EM
MA
NE
RW
SC
Site Offices
NNSA Service Center
BHSO
CH
ID
LASO
LSO
NSO
OH
ORO
ORP
PXSO
RFPO
RL
SR
SRSO
SSO
YSO
External Agency
DNFSB
Preparing Activity:
DOE DR-1
Project Number:
MGMT-0005