DOE-STD-1219-2016, Analysis and Evaluation of the Operability and Reliability of Intrusion Detection and Assessment Systems
Functional areas: Alarm Management, Analysis, Protective Force Equipment
This standard provides an understandable process and methodology of the analysis and evaluation sites should consider conducting as required by Department of Energy (DOE) Order (O) 473.3A, Attachment 3, Section A, Chapter IX, 1.i.(1). In addition, the intent of this standard addresses the protective force equipment needs as outlined by DOE O 473.3A Appendix A, Section C, 2. Equipment and Attachment 2,Section C.3. Equipment.
Document text
Text extracted from the attached file. Refer to the original document for the authoritative version.
Section 1
NOT MEASUREMENT
SENSITIVE
DOE STD-1219-2016
May 2016
DOE STANDARD
Analysis and Evaluation of the Operability
and Reliability of the Intrusion Detection and
Assessment Systems
U.S. Department of Energy AREA SANS
Washington, D.C. 20585
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited
DOE STD-1219-2016
This document has been reproduced directly from the best available copy.
Available to DOE and DOE contractors from ES&H Technical Information Services,
U.S. Department of Energy, (800) 473-4375, fax: (301) 903-9823.
Available to the public on the DOE Technical Standards Program website at
http://energy.gov/ehss/services/nuclear‐safety/department‐energy‐technical‐standards‐program.
i
http://energy.gov/ehss/services/nuclear-safety/department-energy-technical-standards-program
DOE STD-1219-2016
FOREWORD
1. This Department of Energy (DOE) technical standard is approved by all DOE components and
their contractors
2. DOE technical standards, such as this technical standard, do not establish requirements.
However, all or part of the provisions in a DOE technical standard can become requirements
under the following circumstances:
a) they are explicitly stated to be requirements in a DOE requirements document, or
b) the organization makes a commitment to meet a technical standard in a contract or in an
implementation plan or a program plan required by a DOE requirements document.
Throughout this technical standard, the word “shall” is used to denote actions which must be performed if
the objectives of this technical standard are to be met. If the provision of this technical standard are made
requirements through one of the two ways discussed above, then the “shall” statements would be
requirements. It is not appropriate to consider that “should” statements would automatically be converted
to “shall” statements as this action would violate the consensus process used to approve this technical
standard.
ii
DOE STD-1219-2016
TABLE OF CONTENTS
1. SCOPE .................................................................................................................................................. 1
2. PURPOSE............................................................................................................................................. 1
3. APPLICABILITY................................................................................................................................. 2
4. REFERENCES ..................................................................................................................................... 2
5. ACRONYMS AND DEFINITIONS .................................................................................................... 2
6. BASIC ANALYSIS PROCESS............................................................................................................ 6
7. INTRUSION DETECTION SYSTEM CHARACTERISTICS ........................................................... 8
8. EXAMPLE ANALYSIS..................................................................................................................... 26
9. CHARACTERISTIC WEIGHTING .................................................................................................. 28
Section 2
10. ROOT CAUSE IDENTIFICATION .................................................................................................. 30
TABLE OF FIGURES
Figure 1.1 Characteristics of Alarm Management ........................................................................................ 1
Figure 6.1 Analysis Matrix ........................................................................................................................... 7
Figure 6.2 Operability and Reliability Matrix .............................................................................................. 8
Figure 7.1 Alarm Frequency Designation Flowchart.................................................................................. 11
Figure 8.1 Example Analysis Matrix .......................................................................................................... 27
Figure 8.2 Example Operability and Reliability Matrix ............................................................................. 28
TABLE OF TABLES
Table 6.1 Basic Scale .................................................................................................................................... 6
Table 7.1 Alarm Frequency Scale............................................................................................................... 14
Table 7.2 Ancillary Duty Scale................................................................................................................... 15
Table 7.3 Average Alarm Acknowledgement Time Scale.......................................................................... 16
Table 7.4 Ergonomics Scale ....................................................................................................................... 17
Table 7.5 Maintenance Rate and Repairability Scale ................................................................................. 18
Table 7.6 Operator Performance Test Scale ............................................................................................... 19
Table 7.7 Oversight Scale ........................................................................................................................... 20
Table 7.8 Performance Testing Alarm Rate Scale ...................................................................................... 21
Table 7.9 System Interface Scale ................................................................................................................ 22
Table 7.10 Technical Knowledge Scale...................................................................................................... 23
Table 7.11 Testing Frequency Scale ........................................................................................................... 24
Table 7.12 Training Test Scores Scale........................................................................................................ 24
Table 7.13 Z-Score Scale ............................................................................................................................ 26
Table 8.1 System Scale ............................................................................................................................... 26
Table 8.2 Operator Scale............................................................................................................................. 26
iii
DOE STD-1219-2016
Section 3
Table 9.1 Weighted Average Effect............................................................................................................ 28
Table 9.2 Weighted Average Example One................................................................................................ 29
Table 9.3 Weighted Average Example Two ............................................................................................... 29
Table 9.4 Operator Scale Weighted Average Example .............................................................................. 29
iv
Analysis and Evaluation of the Operability
and Reliability of the Intrusion Detection
and Assessment Systems
1. SCOPE
A primary intent of alarm management is to ensure that the system and its components are configured
(including balanced sensitivity and specificity) to minimize unnecessary alarm activation. This allows for
a presentation of alarms at rates that the human operator can assimilate in order to maximize the alarm
management system. The responsible security authority must select, install, configure, implement,
operate, and maintain the system such that the system directs the human operator's attention to the most
important alarm and the operator responds as required. Analyzing and reacting to system and operator
performance data should enable optimization of the system and related human factors/operator interface.
Figure 1.1, Characteristics of Alarm Management, depicts a high-level outline of alarm installation and
operations. The region circled by the dashed line displays what areas of alarm management this technical
standard addresses.
Establish policy
Determine requirements
Design the system
Implement the system Train the operators
Operate the system
Retrieve alarm data
Analyze alarm data
Identify actions for improvement
Perform improvement actions
Figure 1.1 Characteristics of Alarm Management
2. PURPOSE
This standard provides an understandable process and methodology of the analysis and evaluation sites
should consider conducting as required by Department of Energy (DOE) Order (O) 473.3A, Attachment
3, Section A, Chapter IX, 1.i.(1). In addition, the intent of this standard addresses the protective force
equipment needs as outlined by DOE O 473.3A Appendix A, Section C, 2. Equipment and Attachment 2,
Section C.3. Equipment. The analysis allows sites to identify and improve the intrusion detection and
assessment systems (IDS) performance and define vital characteristics of the alarm system and station
operators that influence operation and response. This standard establishes terminology and a
methodology for identifying, analyzing, and communicating characteristics to support planning,
operation, evaluation, and improvement of security system strategy and performance. Characteristics
1
DOE STD-1219-2016
listed may not be valid for all Department locations. This analysis process does not assess the
effectiveness of the site-specific programs when compared to the rest of the department complex.
The analysis in this standard relies on a combination of measurable system and operator characteristics
and subject matter expert evaluation. Analysts and responsible security authorities’ use ratings to identify
and examine weaker performing characteristics. A single poorly performing characteristic may not
indicate the entire IDS is performing below requirements. However, responsible security authorities
should not overlook a poorly performing characteristic. Identifying numerous system and operator
characteristics allows trending, analysis, and correction of the root causes of system or operator
weaknesses. Organizations can use this process to increase their confidence in the operability and
reliability of the IDS. Sites may also elect to employ the processes and results as part of the vulnerability
analysis and risk assessment.
Section 4
Employing the process outlined in this technical standard does not provide a guarantee that security will
detect, address, and classify all alarms effectively. However, the process provides responsible security
authorities with performance data of the IDS and the status of supporting characteristics.
3. APPLICABILITY
This standard applies to all DOE locations employing IDS with system operators to protect assets and
personnel. The Officially Designated Federal Security Authority (ODFSA) and Officially Designated
Security Authority (ODSA) are responsible for analyzing the system.
4. REFERENCES
DOE O 473.3A, Protection Program Operations.
5. ACRONYMS AND DEFINITIONS
5.1. Acronyms:
CAS Central Alarm Station
DOE Department of Energy
FAR False Alarm Rate
FoF Force on Force
IDS Intrusion Detection and Assessment System
LSPT Limited Scope Performance Test
NAR Nuisance Alarm Rate
ODSA Officially Designated Security Authority
ODFSA Officially Designated Federal Security Authority
OJT On-the-Job Training
UAR Unresolved Alarm Rate
5.2. Definitions
Alarm Frequency: Alarm frequency is the characteristic that measures the number of occurrences of
an alarm per unit of time. These are false, nuisance, or unresolved alarms. The environment, system
installation and maintenance, component health, or actual security events can affect the number of
alarms. A system with numerous false, nuisance, unresolved, or authorized alarms may result in
ineffective alarm station operator’s response performance. Alarm frequency is a characteristic of the
system scale.
2
DOE STD-1219-2016
Alarm Rate: Alarm rate is a quantity of alarms with respect to periods of time.
Analysis Matrix: A four-quadrant matrix used to display the system scale and the operator scale. The
matrix provides a visual representation of how the IDS was functioning. The matrix gives an overall
picture of the system health and identifies the weaker scale, as applicable. Identifying the lower
performing scale allows the responsible security authority the opportunity to isolate the problematic
characteristics.
Analyst: The Analyst is the person or group conducting the data gathering, rating of the
characteristic, and plotting the resulting scores on the matrix. This person or group can be
responsible for the entire analysis process or defining the rating of a single characteristic. It is vital
that the analyst remains free of influence and that rating scores remain an honest and accurate
assessment of the characteristic.
Ancillary Duties: Ancillary duties are any additional duties for the operator beyond their primary
duty. As the number of other responsibilities increases for the system operator, the result is less
attention to the system. Ancillary duties are a characteristic of the operator scale.
Authorized Alarm: An authorized alarm is an alarm for which stimulus activated a sensor, but the
sensor was either:
Placed into a state where access is permitted but sensors are still capable of generating an alarm
(for example, the sensor was taken out of service for maintenance or repair and replaced by
compensatory measures), or
Activated by a known, expected, and operationally acceptable cause, such as performance testing
of the IDS. The frequency of performance testing or planned alarm activities may still be a
detriment to the health of the IDS as the operator will become complacent in response if they are
constantly reacting to authorized alarms.
Section 5
Average Alarm Acknowledgement Time: The average alarm acknowledgement time is a measure of
time for the system to receive and display the alarm and the operator to acknowledge the receipt of
the alarm and initiate assessment of the alarm point. Systems personnel generally gather this
information through software analysis of data pulled from the system. This characteristic may also
highlight the importance of a standard operator response to alarms. Average alarm acknowledgement
time is a characteristic of the operator scale.
Characteristics: Characteristics are elements of the system that define how well the system is
functioning and form the basis for rating the level of operator proficiency. The analysis process
employs these characteristics to define the system health and identify weaknesses in system
operation, maintenance, or design. For this Technical Standard, there are 13 total characteristics
identified, eight system focused, and five operator based.
Ergonomics: The scale of human engineering applied to system design and maintenance. A well-
arranged system results in rapid alarm assessment and system operation. A poorly engineered system
requires an operator to move about a room and look in various directions usually resulting in slow
response and possibly missed events. Ergonomics is a characteristic of the system scale.
False Alarm: An alarm for which the specific cause is unknown. Responsible security authorities
may view a false alarm as an unwarranted alarm activated for reasons other than those for which the
alarming device was designed. False alarms can be an indication of electronic malfunction such as
component failure, communications failure, loose connections, power faults, or many other issues.
3
DOE STD-1219-2016
Similar to nuisance alarms, false alarms may occur in any system, but the frequency of these events is
meaningful because they affect operator confidence in the system, and thus, overall security system
performance. The False Alarm Rate (FAR) is the measurement of the frequency of this event.
Intrusion Detection System: A security system consisting of sensors capable of detecting one or more
types of phenomena, signal media, annunciators, energy sources, alarm assessment systems, and
alarm reporting elements including alarm communications and information display equipment. For
the purposes of this technical standard, the operator(s) are considered part of the IDS.
Maintenance Rate and Repairability: A characteristic rate of the frequency and type of maintenance
and the availability of repair and replacement parts required to keep the system functioning as
required. The maintenance rate and repairability scale is a characteristic of the system scale.
Nuisance Alarm: An alarm for which a condition activated the sensor within the intended envelope
and parameters of activation. Nuisance alarms are not related to any intent or activity for which the
alarming device has been designed and operated. Personnel may view a nuisance alarm as a
superfluous alarm in that the alarm has been activated by conditions for which the alarming device
has been designed but not intended. The underlying intent and activity of that which has caused the
activation do not inherently require action to counter a threat. Three of many examples of events that
may activate alarms, but are, in fact, nuisance alarms include presence of an animal in a monitored
location, authorized personnel failing to operate the system and generating an alarm, and weather-
induced alarms. Excessive nuisance alarms may indicate a poor sensor selection for the
environmental conditions. Nuisance alarms may occur in any system, but the frequency of these
events is meaningful because they affect operator confidence in the system, and thus, overall security
system performance. The Nuisance Alarm Rate (NAR) is the measurement of the frequency of this
event.
Section 6
Operability and Reliability: The IDS will detect and dispatch with a level of assurance necessary to
meet security response requirements as identified in supporting security plans and documentation
approved by the ODFSA.
Operability and Reliability Matrix: A four-quadrant matrix used to display the connection between
system performance and expected operational capability. This matrix provides a visual representation
of how the IDS meet detection and assessment requirements. Like the analysis matrix, this matrix
gives an overall picture of the IDS and identifies the weaker scale as applicable.
Operator Performance Test: The operator performance test characteristic is a measure of operator
testing success. Performance tests have pass/fail results and may be performance based or written. A
team separate from the training section should conduct performance test to support this characteristic
rating, though results should be shared with both training and performance assurance groups as
applicable. The operator performance test is a characteristic of the operator scale.
Operator Scale: An average of the five operator proficiency characteristics rated from one to five in
tenths, combined and plotted with the system scale to define the overall operability and reliability of
the IDS. Analysis of the characteristics comprising this scale should encompass not only the
operator’s proficiency but also those external influences such as procedures, policies, and
management decisions that may affect operations.
Oversight: Experienced operators tend to require less oversight than less experienced operators. This
rating addresses how much oversight the operators require beyond initial qualification requirements.
Oversight is a characteristic of the operator scale.
4
DOE STD-1219-2016
Performance Testing Alarm Rate: This alarm rate is a measure of the increase in frequency of alarms
caused by a simulated threat and responding forces. Responsible security personnel should consider
what alarms may be activated and the rate of those alarms during Force on Force (FoF) exercise and
training activities against an appropriate adversary force as defined by the site’s Risk Assessment,
Vulnerability Analysis, as required by the Graded Security Protection Policy. Analysts may assess
the alarm rate during a simulated event such as a tabletop or determine it directly during an actual test
event. This characteristic simulates how the system responds during an assault and the effects on the
operator response. Performance testing alarm rate is a characteristic of the system scale.
Primary Duties: The alarm station operator responsible for the primary alarm system focusing on the
most critical targets or material is primarily responsible for alarm acknowledgement and dispatch.
For example, other duties include documenting and classifying alarms, managing non-alarm response
communications, or controlling access are the responsibilities of other operators or personnel or are
ancillary duties of the alarm station operator (See Ancillary Duties).
Responsible Security Authority: Person or organization responsible for addressing the characteristic
rated. As facilities employ different contractors or organizations to address protective force personnel
and systems, the technical standard employs this neutral term.
Scale: A range of numbers from one to five defining the capability of the characteristics analyzed, a
score of one indicates a poorly performing characteristic and a five reflects an almost perfect
operating characteristic.
Section 7
System Scale: An average of the eight system characteristics rated from one to five in tenths,
combined and plotted with the operator scale to define the overall health of the IDS.
System Interface: This characteristic measures the ease of computer interface and system software
operation. A system requiring a single button push to acknowledge and review alarm data promotes a
rapid and accurate response by security forces. A system with a lengthy interface process using
multiple systems and keyboards to acknowledge and review an alarm generally yields a slower, less
accurate response by security personnel. The system interface is a characteristic of the system scale.
Tamper Alarm: An indication that unauthorized access to a security alarm management and control
system enclosure or device is being attempted.
Technical Knowledge: Technical knowledge is a measure of the skill and training required to
maintain and repair the system. Technical knowledge is a characteristic of the system scale.
Testing Frequency: The number of different personnel and organizations completing system and
operator testing provides a level of assurance that the system is performing as designed. Fewer
different testing entities might indicate that responsible security authorities rarely confirm the system
abilities. More resources looking at the system results in an increased opportunity of finding and
addressing weaknesses in a timely manner. Testing frequency is a characteristic of the system scale.
Training Test Scores: Test scores are a rating of operator understanding of system training and re-
training. Training test scores is a characteristic of the operator scale.
True Alarm: Also known as, an intrusion alarm is a condition activated the alarm for which the
alarming device has been designed and operated (for example, an attempted intrusion by unauthorized
personnel).
5
DOE STD-1219-2016
Unresolved Alarm: An alarm for which the cause has not been determined but investigation of the
cause is still ongoing. The Unresolved Alarm Rate (UAR) is the measurement of the frequency of
this event.
Z-Score: The Z-Score is a statistical measure of the health of the alarm sensor. This measure
identifies if a sensor is operating as expected or if the alarm frequency from the sensor is increasing
or decreasing in an uncharacteristic way, usually indicating the sensor requires repair or replacement.
The Z-Score is a characteristic of the system scale.
6. BASIC ANALYSIS PROCESS
This technical standard establishes thirteen characteristics that provide indication of the health of the IDS.
These generic characteristics are alarm frequency, ancillary duties, average alarm acknowledgement time,
ergonomics, operator performance tests, maintenance rate and repairability, oversight, performance
testing alarm rate, system interface, technical knowledge, testing frequency, training test scores, and Z-
score. These thirteen characteristics are separated into system and operator categories. An analyst,
ideally a subject matter expert not responsible for the characteristic, rates each characteristic from one to
five supported by documented data and evidence. This standard provides a separate scale for each of the
thirteen characteristics in Section 7. Section 7 also provides a narrative of each characteristic and sources
of data and information the analyst may consider using to scale the characteristic. Table 6.1, Basic Scale,
below provides a generic description of each scale level. As the analysts are rating the characteristic the
individual sensor, system, or operator should be rated for better causal analysis and corrective action
development. Increased analysis granularity also supports a more accurate rating of the characteristic.
Section 8
Table 6.1 Basic Scale
Basic Scale
Scale Designator Description
1 Poor Operating well below levels defined in Section 7
2 Moderate Operating below levels defined in Section 7
3 Fair Operating at levels defined in Section 7
4 Good Operating above levels defined in Section 7
5 Excellent Operating well above levels defined in Section 7
Once analysts have identified and rated all characteristics, the analyst responsible for the entire report
then averages the characteristics as part of either the system scale or the operator scale. The analyst
rounds the average result of each scale to the tenths (0.01-0.04 round down to 0.0 and 0.05-0.09 round up
to 0.1) and plots the resulting point on the analysis matrix to identify the IDS operability and reliability.
The horizontal axis of the matrix is the system scale and the vertical axis is the operator scale, refer to
Figure 6.1, Analysis Matrix, below. The analysis matrix is broken into four quadrants emphasizing the
strengths and weakness of the IDS, refer to the Analysis Matrix Definition Chart 6.1 below. The goal of
this process is to provide a visual representation of the health of the IDS. As resources are generally
scarce, any response to characteristics performing poorly should begin with a detailed investigation of the
causes. The intent is not to make important or costly decisions on averaged values but understand the
health of the IDS as a whole and respond to weaknesses appropriately, as resources allow.
6
http:0.05-0.09
http:0.01-0.04
DOE STD-1219-2016
III I
IV II
System Scale
O
p
er
at
o
r
Sc
al
e
1 2 3 4 5
1
2
3
4
5
Figure 6.1 Analysis Matrix
I – Optimal level of operator proficiency and system performance
II – Low operator proficiency and good system performance, the system is heavily responsible
for the success of operation and detection
III – High operator proficiency and poor system performance, the operator is heavily responsible
for the success of operation and detection
IV – Low operator proficiency and poor system performance, indicative of unsatisfactory overall
performance.
Chart 6.1: Analysis Matrix Definition
After plotting the system and operator scale on the analysis matrix, the analyst should identify the
location of IDS health based on Figure 6.2, Operability and Reliability Matrix, below. This matrix is
similar to the analysis matrix. However, this matrix includes an overlay of colors denoting the expected
operational area of the IDS, the color the plot should fall within, based on the assets protected defined in
the Operability and Reliability Matrix Definition Chart 6.2 below. If the plotted value is near the border
of the overlay, the responsible security authority should investigate and begin causal analysis and
corrective actions to address the weakness. Again, as resources are generally scarce any response to
characteristics performing poorly should begin with a detailed investigation of the causes. The intent is
not to make important or costly decisions on averaged values but rather be aware of the health of the
system and correct weaker performing characteristics as resources become available. Analysts shall
document all decisions in a report reviewed by the responsible security authorities and approved by the
ODFSA. The report shall highlight the strengths and weaknesses of the IDS so responsible security
authorities can make resource adjustments as necessary. Analyst should present the report to the ODFSA
on a periodic (annually, semi-annually, or quarterly) basis for tracking and trending purposes.
Section 9
7
I
DOE STD-1219-2016
Each site has specific training, testing, and detection requirements established specifically for their
security needs. Responsible security authorities should not use scores from this process when compared
to other locations as the basis for changing a program. For example, a location rating their training poor
due to low test scores should not adjust their training lesson plans to mirror another location with a higher
rating, unless additional process improvement techniques are employed that support these changes. The
analysis completed by responsible security authorities should use the terminology provided in this
standard when possible and define any site-specific system characteristics as applicable.
III
IV II
System Scale
O
p
er
at
o
r
Sc
al
e
1 2 3 4 5
1
2
3
4
5
Figure 6.2 Operability and Reliability Matrix
Red – Systems protecting CAT I/II, Top Secret material (Outer edge of scale is 3.2 for both
System and Operator) are excellent.
Blue – Systems protecting CAT III/IV, Confidential/Secret material (Outer edge of scale is 2.5
for System and Operator if the opposite scale rates at 3.2) are above average.
Yellow – Systems protecting personnel and other governmental property (Outer edge of scale is
2.0 for System and Operator if the opposite scale rates at 3.1) are average.
White – Systems are operating unsatisfactorily (Outer edge of scale is between 3.1 and 2.0 for
System and Operator if the opposite Scale rates below 3.1. Scale may be as high as 5.0 and still
unsatisfactorily if the opposite scale is below 2.0).
Chart 6.2: Operability and Reliability Matrix Definition
7. INTRUSION DETECTION SYSTEM CHARACTERISTICS
Outlined below are descriptions for each characteristic, sites should consider including in analysis
techniques. Each characteristic reviewed may have multiple conflicting points of data when compared to
the chart. Within a characteristic, some data may indicate better performance scoring a four or five and
8
DOE STD-1219-2016
other data may indicate poor performance scoring a two or three, making analysis challenging. For
example, a Central Alarm Station (CAS) may have many stationed operators with few ancillary duties
resulting in only one ancillary duty per person with the ancillary duties aligned to their system operations.
This example situation should initially score a four on the ancillary duties characteristic scale. However,
during an exercise the analyst identifies that the ancillary duty requirements result in a vulnerability
indicating a rating of two on the scale. In this case, the analyst developing the score shall document both
results. If the vulnerability is such that the responsible security authority cannot quickly address the issue
or the vulnerability requires prolonged time and resources to fix, the ancillary duty characteristic may
score a two. However, if the vulnerability is of a limited nature and quickly corrected, the analyst could
assign a score of four once mitigated. A formal analysis of the issue identified is required along with any
possible mitigations and corrections to justify any rating shift. This is a case where the prudent decision
is to maintain the score of two until the responsible security authority can correct the concern
permanently.
Section 10
Another aspect of consideration for the analyst is the cross effect of characteristics. For example, if the
analyst elects to monitor alarm frequency during a rainstorm and use this as their baseline alarm
frequency the results may show a higher level than actually present during a non-rainy day. This poor
analysis decision results in a lower score on the alarm frequency scale and possible difficulty in clearly
rating other characteristics. Analysts should be aware of the characteristic they are measuring and limit,
as much as practicable, the impacts of other characteristics at the time of measurement and analysis.
Characteristics identified below are not applicable to all facilities and sites but are concepts sites should
consider when analyzing the health of their IDS. As part of the site-specific analysis, the documentation
should include all applicable characteristics and the terminology to define what the characteristic
addresses. Site-specific analysis should document the information to support any characteristic weighting
(refer to Section 9 of this standard) or adjustments to the matrix. Other sources of information used to
define site-specific characteristics include assessments, performance tests, risk analysis, vulnerability
analysis, and procedures.
7.1. Alarm Frequency
Alarm data analysis and performance evaluation provides information that is useful for determining
current sensor performance, sensor performance trends and patterns, and uncovering potential to
improve sensor, and thus system, performance. Analyzing the state of a system with defined
evaluation methods is essential because it establishes empirical and quantifiable evidence of
performance that the responsible security authority compares to policy and requirements. It also
provides feedback on improvement initiatives and motivation/justification for required upgrades or
other expenditures.
Analysis and rating of the alarm frequency characteristic does not require separate analysis of
FAR/NAR/UAR. The alarm frequency characteristic focuses on the system as a whole. Unplanned
alarms that are not actual security threats impact the operator’s faith in the system regardless of the
final designation by the operator or system. Identifying the alarm as FAR/NAR/UAR is more vital
for corrective actions by system technicians. An analyst should consider breaking down the data for
causal analysis and corrective actions. If the granularity identifies one of the rates as a dominant
issue, then the responsible security authority should address that aspect of the characteristic. The
intent of reviewing alarm frequency is to ensure the alarm rate does not impact the health of the
system and the faith of the operator in the system.
Each site should have a documented process in place to retrieve, process, analyze, and identify
corrective actions to manage the FARs/NARs/UARs. This process should include performance
thresholds used by the responsible security authority in determining whether sensors comply with all
9
DOE STD-1219-2016
relevant policies and requirements. Many data analysis software options/packages are able to
calculate the numbers used in analyzing sensor performance data once the software is configured
properly and provided the appropriate data.
Section 11
Figure 7.1, Alarm Rate Designation Flowchart, shows a flowchart for classifying the alarm type. This
flowchart involves processes associated with the “Operate the system” block in Figure 1.1,
Characteristics of Alarm Management, because it is the mental process that operators or others go
through while assessing each alarm and is illustrative of how alarms are assigned to the various
groups. There is some flexibility in how the responsible security authority assigns each alarm to a
group. For example, the console operator, a maintenance representative, the system, or another entity
that identifies the cause and relevant parameters for making the change should regroup an initially
unresolved alarm as a false alarm.
10
DOE STD-1219-2016
Signal from
sensor received
Alarms
Enabled?
No
Record as
Unresolved
Alarm
Real or
attempted
intrusion?
Caused by
authorized
activity?
Cause has not
been determined
but investigation
of the cause is
still ongoing
Sensor activated
within its intended
detection envelope
and parameters.
No alarm data
recorded
Try to determine
cause
Initiate response
Yes
Yes
Yes
No
No
No
No
Can cause be
determined?
Yes
Yes
No
Record as True
Alarm
Record as
Authorized
Record as Nuisance
Alarm
Feed-in to “Retrieve
alarm data” process in
Figure 1.1
Change to record
as False Alarm
Retain record as
Unresolved
Yes
Figure 7.1 Alarm Frequency Designation Flowchart
Once the parameters are established, appropriate management should define thresholds. To calculate
the alarm rate, simply divide the number of alarms for a particular sensor by the associated time
range. However, when developing a practical approach, several questions arise. These questions
include, but are not limited to:
What is the appropriate time range?
How should the number of alarms be based? On one sensor, a protection zone, or some other
clustering?
The significance of the appropriate time range of each individual alarm to the rate are reduced if the
associated time range is increased. However, increasing the time range may also increase the number
of subject alarms. The units used for the alarm rate characteristic are “alarm” and “hour,” with the
ratio being “alarms per hour.”
11
DOE STD-1219-2016
It is meaningful to view alarm rate distributions according to very short or very long time frames,
although this standard cannot address all possible scenarios, it does address the rates on a daily and
weekly cycle. An example of a short time frame consideration is a situation where the sun being at a
particular position affects a sensor or group of sensors at a certain time of day during a specific time
of year. This scenario may result in an exterior sensor activating many times in a one-hour period for
those days, but the rest of the day not activating at all. In this case and for this particular sensor, it is
meaningful to analyze the collected sensor performance data on an hourly basis. An example of
longer periods is seasonal changes resulting in sensor performance that repeats over multiple years.
The basic topics for analysis performed according to this standard include:
Daily Individual Alarm Counts
Daily Individual Alarm Rates
Daily Individual Alarm Outliers
Weekly Individual Alarm Counts
Weekly Individual Alarm Rates
Weekly Individual Alarm Rate Means
Weekly Individual Alarm Rate Standard Deviations
Individual Alarm Statistical Thresholds
Section 12
Daily Individual Alarm Counts: Record the number of True, Authorized, Nuisance, False and
Unresolved Alarms that occurred for each individual sensor during the 24-hour day, beginning and
ending at midnight of consecutive days.
Daily Individual Alarm Rates: Record the True, Authorized, Nuisance, False and Unresolved Alarm
Rates for each sensor by dividing its Daily Alarm Count by 24, resulting in rate units of (true,
authorized, nuisance, false and unresolved) alarms per hour.
Daily Individual Alarm Outliers: Based on the Individual Alarm Statistical Thresholds, identify any
daily rate that has exceeded the threshold established for that sensor. Security or site managers
should also set thresholds based on relevant information regarding the sensor, its environment, the
security system configuration or operation, or other pertinent factors. The decision to use statistically
developed thresholds use the assumption that the sensors and security system are adequately
designed, implemented and operated. These assumptions support the concept that statistically high
rates indicate that action is required to identify and rectify any current or emerging problems.
Weekly Individual Alarm Counts: Sum and record the number of True, Authorized, Nuisance, False
and Unresolved Alarms that occurred for each individual sensor during the seven consecutive day
period.
Weekly Individual Alarm Rates: Sum and record the number of True, Authorized, Nuisance, False
and Unresolved Alarms that occurred for each individual sensor during the seven day week, then,
divide by 168 hours to result in rate units of (true, authorized, nuisance, false and unresolved) alarms
per hour. The approach that an average of the daily rates and some potentially available variability
and distribution information is not applied should be sufficient for determining the center and basic
variability of the sensor performance data, which analysts should use to develop the Individual Alarm
Statistical Thresholds.
Weekly Individual Alarm Rate Means: Analysts should consolidate each weekly individual alarm
rate with all other available weekly individual alarm rates for the same sensor and its alarm groups so
that the center of this data collection is determined. The center of data used by this standard is the
12
DOE STD-1219-2016
mean. One method for determining the mean is to sum all of the Weekly Individual Alarm Rates for
a particular sensor, by group (a collection of sensors in a defined vicinity (e.g., vault or zones/sectors
of intrusion detection, etc.) not necessarily all of the same type of sensor), and then divide by the
number of Weekly Individual Alarm Rates. For example, if seven weeks’ of Weekly Individual
Alarm Rates are recorded and those rates for unresolved alarms are: 27, 34, 12, 41, 29, 27 and 31
unresolved alarms per hour, then the Weekly Individual Alarm Rate Mean for that sensor, regarding
unresolved alarms, is:
(27+34+12+41+29+27+31) / 7 = 201 / 7 = 28.7 unresolved alarms per hour (rounded).
Weekly Individual Alarm Rate Standard Deviations: The analyst derives the standard deviation from
the data in the frequency distributions assembled from the Weekly Individual Alarm Rate Means.
The standard deviation is the square root of the average of the squared differences from the mean,
thus:
s ൌ ඩ
1
െ Xሻ
ଶ
N െ 1
ሺX୧
୧ୀଵ
Where N is the same sample size, xi is an individual score, and xbar is the mean.
Section 13
This formula uses N-1 instead of N in front of the summation sign because it is the standard deviation
formula for a sample rather than a population.
Calculators, spreadsheets, statistical programs, and other software have functions for calculating
standard deviation. As an example of the actual calculation, for the standard deviation for the
numbers, 27, 34, 12, 41, 29, 27 and 31 unresolved alarms per hour, the following approach may be
used:
xi xi - mean (xi - mean)2
27 -1.71429 2.939
34 5.28571 27.939
12 -16.7143 279.367
41 12.28571 150.939
29 0.28571 0.0816
27 -1.71429 2.939
31 2.28571 5.224
SUM: 469.429
SUM/6: 78.238
Square Root: 8.845
The standard deviation from this data set is s = 8.9 unresolved alarms per hour (rounded).
Individual Alarm Statistical Thresholds: The method for determining the thresholds for individual
sensor performance data is to compare the Daily Individual Alarm Rates directly to the Weekly
Individual Alarm Rate Means and the Weekly Individual Alarm Rate Standard Deviations.
13
DOE STD-1219-2016
Using the statistical techniques above allows the analyst to rate the alarm frequency characteristic
using Table 7.1, Alarm Frequency Scale, below and prepares to develop data to support rating the Z-
Score characteristic.
Table 7.1 Alarm Frequency Scale
Alarm Frequency
Scale Description
1 Interior Alarm 1 every 8 hours or Exterior Alarm 1 every hour
2 Interior Alarm 1 every 24 hours or Exterior Alarm 1 every 4 hours
3 Interior Alarm 1 every 240 hours or Exterior Alarm 1 every 8 hours
4 Interior Alarm 1 every 2400 hours or Exterior Alarm 1 every 24 hours
5 Interior Alarm 1 every 4800 hours or Exterior Alarm 1 every 48 hours
7.2. Ancillary Duties
The primary focus of alarm system operators should be the response to alarm systems protecting
department personnel and material. However, the system operators have a unique position of
responsibility and capability, as they are stationed in one location, usually central to the facility. Due
to this central location, additional tasks are often assigned to these individuals. These additional tasks
include radio communications, equipment assignment, access control, long-range detection system
operation, and video assessment systems operations, among others. These tasks may range in
difficulty from very simple data logging to very complex system operations and analysis.
Additional tasks require system operators to multitask, especially during alarm situations. Studies
have shown that task shifting or multitasking results in negative effects on accuracy1. Furthermore,
forced multitasking produces significantly negative results2, forced shifting common in alarm
response activities. Although alarm systems have visual and audible alarm notification, the ancillary
duty requirements may still delay or hinder alarm response actions.
Ancillary duties are part of the operator scale and should be a ratio based on the number of operators
assigned to the alarm station per work shift. Station orders, response plans, and security plans should
outline ancillary duties of the alarm station operators. Additionally, the analyst assigning the rating
should get insight by interviewing and observing the station operators. Analyst observation is vital to
identify the number of task shifts required during daily activities and alarm response demands and the
negative impact of the ancillary duties.
Section 14
Most sites assign more system operators during working hours to address the volume of duty
demands and requirements. Off-shift times tend to have fewer assigned operators and fewer
responsibilities. Since the analyst should quantify alarm station staffing and the number of duties, the
data should be easily recorded and analyzed. If there are differences in shift assignment, the analyst
should elect to either perform an analysis on both shifts separately or combine the two in an average
scale. No matter the decision, analysts should assign each separate station or post a scale rating to
identify possible weaknesses or enhancements, for future causal analysis.
Another aspect of the analysis of ancillary duties is whether the additional duty aligns with the alarm
station primary responsibilities. For example, the CAS has a primary focus of a single facility with a
Material Access Area (MAA). As part of the CAS ancillary duties, the operator provides access
control to certain areas within the MAA. This is an ancillary responsibility but aligns with their
1 Adler, R.F. & Benbunan-Fich, R. (2011). Juggling on a high wire: Multitasking effects on performance.
International Journal of Human-Computer Studies 70 (2012) 156-168
2 Buser, T. & Peter, N. (2011). Multitasking. Experimental Economics 15.4 (2012) 641-655
14
DOE STD-1219-2016
primary responsibilities since it keeps attention of the operator on the facility of interest. If on the
other hand, the CAS operator is responsible for alarms at the MAA and at a limited area outside of
and not directly associated with the facility this duty does not align with their primary responsibility,
even if the limited area uses the same alarm monitoring and access control system as the MAA
facility.
Analysts should identify additional data supporting the rating of this topic while reviewing how the
alarm station operator(s) respond during exercise activities. If the ancillary duty requirements are
numerous but the operator(s) are experienced, general daily activities may not highlight the impact of
these additional duties. This analysis can be an objective for the exercise or test. The analyst should
use caution to ensure the impact of ancillary duties are observed and not the characteristic of
Performance Testing Alarm Rate or that data for both characteristics remains separate if analyzed
concurrently.
Referring to Table 7.2, Ancillary Duty Scale, below the analyst should qualitatively rate the
quantitative data.
Table 7.2 Ancillary Duty Scale
Ancillary Duty
Scale Description
1 Each operator is responsible for three or more other duties not aligned to system
operations. The operator cannot complete all assigned duties related to the primary
alarm system. During an exercise or actual alarm response, operators fail to address
many alarms and a clear vulnerability exists. During alarm response, task shifting
may occur more than 15 times within a half hour.
2 Each operator is responsible for one or two other duties not aligned to system
operations. The operator cannot complete all assigned duties related to the primary
alarm system. During an exercise or actual alarm response, operators fail to address
some alarms and a possible vulnerability exists. During alarm response, task shifting
may occur between 11 and 15 times within a half hour.
Section 15
3 Each operator is responsible for three or more other duties aligned to system
operations. The operator cannot complete all assigned duties related to the primary
alarm system. During an exercise or actual alarm response, operators fail to address a
few alarms but no apparent vulnerability exists. During alarm response, task shifting
may occur between 5 and 10 times within a half hour.
4 Each operator is responsible for one or two other duties aligned to system operations.
The operator can complete all assigned duties related to the primary alarm system.
No vulnerability exists. During alarm response, task shifting may occur less than 5
times within a half hour.
5 The operator is only responsible for the primary alarm system focusing on the most
critical targets or material. Alarm acknowledgement and dispatch is the operators’
only responsibility. No vulnerability exists. During alarm response, no task shifting
occurs.
7.3. Average Alarm Acknowledgement Time
The average time for alarm acknowledgement is a characteristic reflecting the speed in which
operators address alarms displayed by the system. Trained operators with defined responsibilities and
clear procedures should be capable of operating the system efficiently ensuring that alarms are
acknowledged, initially assessed, and security forces are dispatched as required. Longer
acknowledgement times could indicate that operators are not sure of responsibilities, the system is not
functioning properly, or the number of sensors the operator is expected to monitor is too high
15
DOE STD-1219-2016
resulting in an excessive volume of alarms. Analysts should rate all personnel and work shifts to
highlight any weaknesses. Analysts may gather and analyze acknowledgement times using data
mining software (e.g.Tableau), running performance tests, or both. Table 7.3, Average Alarm
Acknowledgement Time Scale, identifies a purely quantitative rating of the amount of time required
for the operator to complete initial alarm response actions. Analysts should remove authorized alarms
generated during performance testing or maintenance from the analysis as this can skew the data.
Analyst should develop a separate scale reflecting the acknowledgement time assessed during
performance testing. The analyst should use the data to support the rating of the Performance Testing
Alarm Rate characteristic and any causal analysis conducted to identify the root weakness affecting
the IDS. Analysts should also adjust this scale in the final report to reflect the site-specific
vulnerability analysis and response timeline requirements.
Although this characteristic is part of the operator scale, if problems emerge, a causal analysis may
identify other aspects affecting this characteristic such as procedures, communications, system
functionality, etc. In addition to pulling time data from software, analysts should observe the
operators and system to understand how these aspects influence the time. Although this characteristic
is an average, analysts should be aware of and investigate extreme outliers for causal analysis and
corrective action.
Table 7.3 Average Alarm Acknowledgement Time Scale
Average Alarm Acknowledgement Time
Scale Description
1 Greater than 60 seconds
2 Greater than 45 seconds but less than or equal to 60 seconds
3 Greater than 30 seconds but less than or equal to 45 seconds
4 Greater than 20 seconds but less than or equal to 30 seconds
5 Less than or equal to 20 seconds
Section 16
7.4. Ergonomics
This characteristic is a rating of how well engineers designed the system to support the operator(s).
This is an important characteristic, as a well-engineered system makes operations simple, pain free,
and convenient. Systems with everything within reach without straining by the operator are likely to
result in quicker, more accurate alarm response. Facilities that require one operator to move across
the room to operate numerous systems or scan a wall of monitors to assess an alarm have slower
response times and are burdensome on the operator.
The Department of Labor through the Occupational Safety and Health Administration (OSHA)
provides an appropriate tool for assisting in rating the ergonomic characteristic. The Computer
Workstations eTool is a fillable form used to create a safe and comfortable computer workstation.
The form is online at
https://www.osha.gov/SLTC/etools/computerworkstations/checklist_evaluation.html. A ‘No’
selection on the form could indicate a problem.
When a number of system operators are assigned to the alarm station, this scale should analyze each
operator’s workstation and rate the whole layout. As work schedules influence the number of
personnel assigned to the alarm station, analysts have to review conditions during working and non-
working hours. Many Department locations employ more than one alarm station, which may also
require a separate review and rating. This characteristic is part of the system scale and is more of a
qualitative characteristic rating scale. For this reason, analysts sometimes elect to employ a health
16
https://www.osha.gov/SLTC/etools/computerworkstations/checklist_evaluation.html
DOE STD-1219-2016
professional, specially trained to review the ergonomic arrangement of workstations and recommend
a rating using the scale presented in the Table 7.4, Ergonomics Scale, below.
Table 7.4 Ergonomics Scale
Ergonomics
Scale Description
1 Duty station fails to conform to the operator, lighting levels are lacking (Less than or equal
to five footcandles at the workstation), ambient noise is too excessive (greater than or equal
to 75 decibels or greater), the operator is required to stand and move to address alarms and
dispatch security, workstations are more than an arm length apart. Analysts using the OSHA
Computer Workstation eTool selected more than six ‘No’s on the form.
2 Duty station conforms to the operator, lighting levels are limited (greater than five
footcandles but less than or equal to ten footcandles at the workstation), ambient noise is
high (70 decibels or greater), the operator is required to stand and move to address alarms
and dispatch security, workstations are about an arm length apart. Analysts using the OSHA
Computer Workstation eTool selected between five and six ‘No’s on the form.
3 Duty station conforms to the operator, lighting levels are acceptable (greater than ten
footcandles but less than or equal to twenty footcandles at the workstation), ambient noise is
moderate (60 decibels or greater); the operator is required to stretch and stand to address
alarms and dispatch security. Analysts using the OSHA Computer Workstation eTool
selected between three and four ‘No’s on the form.
4 Duty station strongly conforms to the operator, lighting levels are good (greater than twenty
footcandles but less than or equal to fifty footcandles at the workstation), ambient noise
limited (55 decibels or greater), multiple computer stations are required to conduct alarm
activities abut all are within arm’s reach with only limited movement require to observe and
dispatch security. Analysts using the OSHA Computer Workstation eTool selected between
one and two ‘No’s on the form.
Section 17
5 Duty station seems to be engineered for the operator individually, lighting is excellent
(greater than fifty footcandles at the workstation), ambient noise levels good (less than 50
decibels), all operations are within immediate reach and require no additional movement to
observe and dispatch security. Analysts using the OSHA Computer Workstation eTool
selected no ‘No’s on the form.
7.5. Maintenance Rate and Repairability
A system requiring more frequent or intensive maintenance may lead to a weakness in system
operability and reliability, potentially affecting the operator’s faith in the system. Systems that fail to
operate properly require more compensatory measures or may fail to alarm as required. Table 7.5,
Maintenance Rate and Repairability Scale, below is part of the system scale and is quantitative in
nature. Analysts should track corrective maintenance records, including corrections made due to
performance testing results. Characteristics that have analysis that is more granular produce better
utility in supporting a causal analysis. The analysis granularity should focus on maintenance
frequency down to the individual sensor but should score based on an average for the entire IDS for
rating purposes.
Analysts should identify sources of data by reviewing maintenance records and system operator
records. The frequency of maintenance may also be reflective of the age of the system, resulting in a
low score for both repairability and maintenance. If the site employs system technicians, analysts
should note the frequency of assistance by external technicians or manufacturing sources that also
result in an impact to the Technical Knowledge characteristic. The size of the system and the number
of technicians may also be a data point analysts should review. A system with numerous sensors
17
DOE STD-1219-2016
protecting multiple facilities is likely to have more frequent repair maintenance than a small office
with limited sensors. Analyst’s data should reflect the size of the system and number of technicians
as part of the analysis process. The technical standard does not intend this scale to address the single
catastrophic event such as lightning strikes or flooding requiring large system replacements but rather
the average efforts required to keep the system running on a daily basis.
Additionally, a newer system with many options for repair and replacement parts increases the
operator trust in the system and likelihood that the system is performing at optimum levels. By
contrast, a system that is mature with limited repair options and requires technicians to generate
replacement parts or cannibalize other systems to maintain operations is likely to be operating at less
than ideal levels. A well-operating system works in conjunction with talented operators to ensure
protection of assets. A mature system operating at the end of life requires talented operators to
address alarms and respond accordingly. Systems should not remain at this senior stage of their
repairability. One point of caution, a senior system may still be very effective if parts are common
and inexpensive and repairs are easy. Analysts should document decisions on their scales to ensure
sites do not use precious resources to replace established systems simply to purchase the ‘latest’
device.
Section 18
Sources of information for rating this characteristic should include system installation manuals,
drawings, purchase orders for replacement parts and maintenance records, among other things. Like
many other scales, analysts should apply this rating differently to the different supporting systems.
For example, an alarm system over ten years old that had the access control system replaced within
the past year requires the analyst to average the results or complete the analysis separately for each
system and average the results for an overall picture.
Table 7.5 Maintenance Rate and Repairability Scale
Maintenance Rate and Repairability
Scale Description
1 Corrective maintenance is a daily occurrence and is commonly a costly piece of equipment
or system replacement. On average compensatory measures are in place for months.
Replacement parts are not available or are expensive (>$5,000), and are difficult to obtain
with over three months waiting time, system is greater than ten years old and no longer
supported by the manufacturer.
2 Corrective maintenance is almost a daily occurrence and is commonly a major piece of
hardware (multiple sensors, extensive wiring, cards within the data gathering panel). On
average compensatory measures are in place for weeks. Replacement parts are of limited
availability, are expensive (less than $5,000 but greater than or equal to $1,000), and are
difficult to obtain with over two months waiting time, system is ten years old.
3 Corrective maintenance is less frequent (once a week) and is commonly a minor hardware
replacement (sensor head). On average compensatory measures are in place for a week.
Replacement parts are available but difficult to obtain, are moderately expensive (less than
$1,000 but greater than or equal to $500), with over one month waiting time to get parts,
system is less than eight years old.
4 Corrective maintenance is infrequent (once every couple of weeks) and usually a minor
system or setting adjustment. On average compensatory measures are in place for days.
Replacement parts are available, are moderately inexpensive (less than $500 but greater or
equal to $100), are easier to obtain with less than one week waiting time, system is less than
five years old.
5 Limited system corrective maintenance (once a month), on average compensatory measures
are in place for hours. Parts are easily obtainable by the technician at a local supplier and
cost less than $100, system is less than three years old.
18
DOE STD-1219-2016
7.6. Operator Performance Test
Analysts use operator performance test to determine how well operators are performing and
maintaining system knowledge. As with all performance tests, performance based tests are
preferable, written knowledge exams are acceptable, and most sites use a blend of the two methods.
An important aspect of an operator performance test is that the responsible security authority
conducts the test separately from training. Performance tests should have a clear pass/fail result and
provide no re-training. The intent of the performance test is to closely mirror real activities and
generate real operational data. It is common for performance tests results to be slightly less favorable
than training results as there is little if no preparation provided for a performance tests.
Section 19
The responsible security authority, performance-testing section, quality assurance section, or an
external assessment, provides performance test data. Analysts, or those responsible for maintaining
performance test scores and results, should maintain them for the individual operators to allow for
better causal analysis should analysts identify a weakness. Analysts should also track performance
test data by topic or title for the same reasons.
Table 7.6, Operator Performance Test Scale, is part of the operator scale. Some common
performance tests include but are not limited to, alarm response procedures, system operations, record
keeping, and notification procedures. Analysts should rate this characteristic based on the percent of
passing results. As with most characteristics in this analysis, the performance tests characteristic is a
quantitative value. Additionally, the responsibility rests with the analyst to ensure the performance
test information used is applicable to the job of interest. For example, the performance-testing section
completing a performance test on the operators concerning their knowledge of deadly force is
unlikely to apply to alarm systems operation. Analysts should include other styles of testing such as
Alarm Response and Assessment Performance Test and FoF exercises focusing on the resulting data
for the performance test characteristic.
Analysts should always be aware of disparities in results conducted by different assessment groups.
Slight differences in the conduct of the test, test objectives, or testing methodologies may create
differences in the results. The testing criteria and results should be reviewed and, in some cases, the
analyst could conduct their own testing or observe numerous testing events by multiple sources to
ensure data integrity and consistency. Testing scores outlined below are based on criterion-
referenced grading systems as defined by the Department of Education.3
Table 7.6 Operator Performance Test Scale
Operator Performance Test
Scale Description
1 Average test scores less than 65%
2 Average test scores between 65% - 75%
3 Average test scores between 75% - 85%
4 Average test scores between 85% - 95%
5 Average test scores between 95% - 100%
7.7. Oversight
Another method of assessing the expertise of the system operators is to measure the amount of
required oversight or leadership. The oversight characteristic is a scale of the amount of supervision
required for the operator to respond to alarms appropriately. Oversight includes but is not limited to,
uniformed supervisors, training instructors, or senior system operators. The focus of the oversight
3 Department of Education (2008) Structure of the U.S. Education System: U.S. Grading Systems. Located at
www2.ed.gov/about/offices/list/ous/international/usnei/us/grading.doc
19
DOE STD-1219-2016
characteristic is not the amount of training and supervision required prior to operator qualification,
but the amount of additional attention provided to the operator to maintain proficiency. An alarm
station is a location for command and control by leadership, simply observing the presence of the
supervisor near the operators is not indicative of the oversight characteristic. Accurately assessing
this characteristic may require analysts to complete a baseline review of oversight duties to ensure
rated activities are above and beyond the directed amount of oversight required by the responsible
authority. The oversight characteristic focuses on active oversight actions between an experienced
authority and operator. Oversight is not always a senior position over a subordinate position.
Section 20
A properly trained system operator should be able to acknowledge, assess, and dispatch to alarm
stimulus correctly without the assistance or direction of oversight. Analysts should be able to assess
the oversight characteristic by rating each operator separately and averaging the score. Rating the
individual is vital for this characteristic as operators can be entry level or ten-year veterans with
established levels of experience, rating this characteristic based solely on one or the other could result
in an inaccurate score. Rating individually is also valuable as a causal analysis tool to identify
corrective actions.
The analyst gathers data to support the score for this characteristic by observing daily operations,
reviewing operator performance documentation, and interviewing the supervisors and support
provided to the operators. Another source of data should be observation of the operators during
testing activities. Analysts or responsible security authorities identify weaknesses in operational
performance not highlighted during daily routine operations. As with all other assessments, analysts
should be sensitive in data collection and ensure they are assessing and rating the correct
characteristic. Analysts should use Table 7.7, Oversight Scale, below to rate this characteristic. This
characteristic is part of the operator scale.
Table 7.7 Oversight Scale
Oversight
Scale Description
1 The operator cannot operate the system unsupervised. During a normal workweek, oversight
is present more than 75% of the time to oversee operator activities.
2 The operator can operate the system with little oversight. During a normal workweek,
oversight is present approximately 50% of the time to oversee operator activities.
3 The operator can operate the system with little or no oversight. During a normal workweek,
oversight is present less than 25% of the time to oversee operator activities.
4 The operator provides experience to others operating the system. No oversight is present and
the operator assists others in operating the system or in developing procedures and training
documentation on operating the system.
5 Although responsible for system operation, the operator is considered a subject matter expert
and frequently conducts On-the-Job-Training (OJT) to train others to operate the system.
7.8. Performance Testing Alarm Rate
Alarm rates and operator proficiency are vital during actual alarm events. No other characteristic
reflects this like the Performance Testing Alarm Rate. The primary purpose of this alarm rate is to
identify how a full-scale exercise, such as a FoF, increases the alarm rate. This testing or training
event should be representative of the actual numbers of aggressive forces that assault the facility as
defined by the graded security protection policy and thereby indicate the number of alarms that
analysts should reasonably expect during that kind of event. The system and operators should be able
to address all alarms and dispatch protective force personnel as required, in addition to providing
security awareness to responding forces. This characteristic rates the system’s alarm levels separate
from the operator performance test or oversight characteristics which are used to rate the operator’s
20
DOE STD-1219-2016
success at addressing the number of alarms generated by these tests. Analysts may identify the alarm
rate during a simulated event such as a tabletop or measured directly during an actual test event.
Section 21
As with the operator performance test characteristic, analysts should rate this characteristic during
exercise activities supported by alarm logs and acknowledgement time data. Unlike the operator
performance test characteristic, analysts should only rate this characteristic during extensive exercises
such as a FoF. Rating only at this time identifies the most alarms that are likely to be present and
truly assesses the effects on the system. Stressing the alarm system in this manner should be an
objective of the test itself. Analysts should be aware that FoF activities are dynamic and analysis is
different based on the scenario. This characteristic is part of the system scale.
As with rating using other scales, the analyst may touch on many points within the scale as presented
in Table 7.8, Performance Testing Alarm Rate Scale. Again, analysts are required to rate the various
effects and justify their rating to ensure the responsible security authority can identify and address
weaknesses. This scale is unique in that it presents analysts with the description of the operator’s
abilities but focuses on the system’s alarms. The scale focuses in this manner to indicate the effect of
the numerous alarms and communications required during response activities. Rating in this manner
is also necessary as these alarms are intentionally part of the event and analysts cannot rate it as
outlined in the Alarm Frequency characteristic. A well-engineered and maintained system should
present only a limited number of pathways that operators can easily respond to while possibly
conducting other ancillary duties. Analysts should observe numerous testing events with different
system operators, as a poorly performing system appears to be effective given talent and experience
of operators.
Table 7.8 Performance Testing Alarm Rate Scale
Performance Testing Alarm Rate
Scale Description
1 During LSPT/FoF testing, the alarms are so numerous operators cannot support the
responding forces and the system crashes.
2 During LSPT/FoF testing, operators cannot respond to communication requirements and
some alarms (less than five) are not addressed, alarm acknowledgement time increases by 2
minutes or more and alarm rate increases by 75%.
3 During LSPT/FoF testing, communication by operators is brief, not all information is
gathered, and a few alarms (less than three) are not addressed, alarm acknowledgement time
increases by 1 minute or more and alarm rate increases by 50%.
4 During LSPT/FoF testing, operators can respond to the system and communicate as required
with little loss of information, no alarms are ignored or missed, alarm acknowledgement time
increases by 30 seconds or more and alarm rate increases by 25%.
5 During LSPT/FoF testing, operators complete all communication, address all alarms, and
make all required notification with no loss of information. There is no noticeable increase in
alarm acknowledgement time.
7.9. System Interface
Analysts use the system interface information in Table 7.9, System Interface Scale, to assess the
number and different types of operational interfaces of the alarm system and other security systems.
A simple system with familiar interface lends to quicker operation with clear alarm display
information and limited interface requirements reducing the difficulty in operation and responding to
the system. Counterintuitively, the system interface is not a scale of system age, as new systems
functionality increases with capability and options, complexity grows.
Section 22
21
DOE STD-1219-2016
Analysts should review the alarm system and supporting systems separately and group the results. If
an operator is responsible for multiple systems with different interfaces and operating characteristics,
more specialization and training is required. In addition, operators will need to be very skilled to
identify issues with the system should so many supporting systems be employed. Separate review is
necessary for causal analysis and corrective actions as well as the score as a whole. As with all topics
affected by multiple sources, analysts are required to document the separate levels of each system
analyzed and average the resultant score.
The analyst identify data for this scale by observing the operations, reviewing operator manuals,
reviewing training lesson plans, and reviewing operating procedures for the system. Observation of
alarm response activities highlight the level of effort required by the operator to respond to system
alarms, identify the cause, and dispatch as necessary. This characteristic is also reflected in other
characteristics such as oversight, performance testing alarm rate, and operator performance tests. As
always, analysts should be very cautious to ensure the characteristic reviewed is specific and not
encroaching on other topics. This topic is part of the system scale.
Table 7.9 System Interface Scale
System Interface
Scale Description
1 Each operator is responsible for more than five separate alarm and observation systems.
Operation requires knowledge of software coding, typing for searches to locate alarms,
switching between software, multiple button clicks to perform any function in the system.
2 Each operator is responsible for more than four separate alarm and observation systems.
Operation requires knowledge of numerous (four or more) software types, typing for
searches to locate alarms, switching between software, multiple button clicks to perform
any function in the system.
3 Each operator is responsible for more than three separate alarm and observation systems.
Operation requires knowledge of some (three or more) software types, menus are drop
down and system has numerous functions that the operator does not use, system requires
little keyboard use to operate effectively.
4 Each operator is responsible for more than two separate alarm and observation systems.
Operation requires knowledge of a couple software types, menus are drop down and some
additional functionality remains but is not employed by the operator, two-button mouse
click to operate most functions, some limited keyboard use required.
5 Each operator is responsible for two or fewer alarm and observation systems. Operation
requires knowledge of a single software type, menus and system operations have no
extraneous features, all options used by the operator, menus are limited or the entire
system can be operated from basic button interface, one button mouse click to operate any
function of the system. No keyboard use to operate the system after login.
7.10. Technical Knowledge
A system requiring specialized training and extensive focused instruction on maintenance procedures
is limited in resources to address problems when they arise. Specialization increases the difficulty of
communicating issues and completing repairs in a timely manner. An effective detection and
assessment system is simple to maintain and difficult to defeat. This scale outlines the impact of
specialized training or tribal knowledge on system operability and reliability. As with most scales in
this process, the analyst should assign a qualitative score based on quantitative input.
Section 23
Analysis of the characteristic is extensive as each system and each technician requires review. The
analyst should complete interviews with technicians and operators, conduct a review of system
maintenance documents, and assess training and lesson plans. As with all topics, the more granular
22
DOE STD-1219-2016
the initial score the easier causal analysis and corrective actions are attained. This topic is part of the
system scale. The technical knowledge characteristic score is a reflection of the maintenance, system
interface, and repairability characteristics. As with other characteristics, analysts should focus their
rating activities on the characteristic and limit the effect or influence of other characteristics.
As the primary interest of this scale is the IDS, this should be the focus of the assigned score as
presented in Table 7.10, Technical Knowledge Scale, below. However, any system for which the
operator is responsible should also be assessed as these systems impact their ancillary duties and
ultimately their trust in the system as a whole. Although this topic appears to be very similar to the
maintenance characteristic, the difference is not the completed maintenance but the effort and
knowledge required to complete it. For example, if a talented and experienced team of technicians
with very specialized knowledge keeps the system running smoothly, maintenance scores very well,
hiding the impact of the specialized/tribal knowledge necessary to keep the system operational.
Scoring this characteristic separately is necessary, especially if the above situation is occurring. By
identifying this situation early, the responsible security authority addresses the issue prior to any shift
in staffing levels. If the technicians assessed are not employees at the site then the characteristic may
not be accurate, it is recommended analysts not use this characteristic to assess the technician until the
warranty has expired or the contract has changed. However, the time to repair, length of
compensatory measures, and cost of parts should still be tracked as part of the Maintenance Rate and
Repairability characteristic.
Table 7.10 Technical Knowledge Scale
Technical Knowledge
Scale Description
1 Specialized school required available from only one source, personnel conducting
maintenance and testing still require six months or more of additional OJT prior to
maintaining the system, use of external technicians or specialists is commonly employed
with almost every repair (50% or greater)
2 Specialized school required, personnel conducting maintenance and testing still require six
months of additional OJT prior to maintaining the system, use of external technicians or
specialists is commonly employed with almost every repair (25% or greater)
3 Local training required, personnel conducting maintenance and testing still require one
month of additional OJT prior to maintaining the system, use of external technicians or
specialists is infrequent with repair (10% or greater)
4 Minor localized training or basic OJT is all that is required to get a system technician
skilled in completing repair and planned maintenance, use of external technicians or
specialists is rare (less than 10%)
5 New employees can readily perform repair and maintenance without additional training
Section 24
7.11. Testing Frequency
Along with the level of testing stringency to confirm IDS health is the frequency of testing. However
this scale, as identified in Table 7.11, Testing Frequency Scale, not only rates the actual amount of
testing but the different organizations responsible. The amount of testing is important to allow
organizations to detect and address problems. The value of different organizations testing is that each
group employs different talent, perspective, and intent. The more review of a topic the more likely
the system is to be effective. This testing frequency applies to not only the sensors but also the
system and supporting characteristics. As such, the analyst should rate system test frequency
separately for a summary score as a total. This characteristic is part of the system scale.
More engagement by responsible personnel increases the faith of the operator in the system. Other
characteristics that reflect or influence the testing frequency are maintenance rate and repairability
23
DOE STD-1219-2016
and operator performance test. The testing frequency should be easy for the analyst to identify in test
plans, reports, and security plans. Analysts gather additional information by conducting interviews,
assessments, and observations of testing activities.
Table 7.11 Testing Frequency Scale
Testing Frequency
Scale Description
1 Performance testing is only completed by an outside agency when the company/site is being
audited. Testing is conducted once a year by the agency
2 One local entity conducts performance testing and an outside agency when the company/site
is being audited. The groups conduct testing once a quarter
3 Two separate entities from different companies or responsible organizations, conduct testing
along with outside agencies during audits. The groups conduct testing once a month
4 Testing is conducted by numerous groups (system technicians, facility representatives,
security officers, performance testing) from more than two associations, and by outside
agencies during audits. The groups conduct testing weekly
5 Testing is conducted by numerous groups (system technicians, facility representative,
security officers, performance testing) from more than two associations, including another
group not associated with the facility or site, and outside agencies during audits. The groups
conduct testing daily
7.12. Training Test Scores
Test scores are a reflection of the effectiveness of initial and continuous training provided by sites for
the system operators. Alone, this characteristic as presented in Table 7.12, Training Test Scores
Scale, below, does not indicate a success or failure on the part of the operator, but is a piece of the
whole picture concerning IDS operability and reliability. Test scores are a quantitative value derived
by the analyst by averaging test score results. As with characterizing operator performance tests, the
analyst should ensure testing included in the analysis reflects system operations and ancillary duties.
Testing scores outlined below are based on criterion-referenced grading systems as defined by the
Department of Education.4
Section 25
The Training Department or Section should have and retain all topic scores for analysis, each operator
should be scored separately to identify those individuals in need of additional attention or training.
Analysts should review training topics and results separately to ensure granularity of the scale. This
score, among others, will fluctuate with experience and test results. As such, analysts should be
aware and document their data collection and analysis process. Analysts should always be aware of
disparities in results conducted by different assessment groups. Slight differences in the conduct of
the test, the objectives, or testing methodologies may create differences in the results. The testing
criteria and results should be reviewed and, in some cases, the analyst could conduct their own testing
or observe numerous testing events by multiple sources to ensure data integrity and consistency. This
characteristic is part of the operator scale.
Table 7.12 Training Test Scores Scale
Training Test Scores
Scale Description
1 Average test scores less than 65%
2 Average test scores between 65% - 75%
3 Average test scores between 75% - 85%
4 Department of Education (2008) Structure of the U.S. Education System: U.S. Grading Systems. Located at
www2.ed.gov/about/offices/list/ous/international/usnei/us/grading.doc
24
DOE STD-1219-2016
Training Test Scores
Scale Description
4 Average test scores between 85% - 95%
5 Average test scores between 95% - 100%
7.13. Z-Score
Referring back to the alarm frequency characteristics, another useful statistical tool used to normalize
the data for evaluation is the Z-Score. Analysts use the Z-Score to determine the most current sensor
performance, and compare these results with the statistically developed “normal” or “typical”
performance of that same sensor.
Analyst shall complete calculations for the Z-Scores at the same frequency as calculation of the
Alarm Frequency characteristic. The result should be that the sensor’s Z-Scores indicate how many
standard deviations away from the mean the current day’s performance is.
The Z-Score provides the relative position of a score with respect to the mean. The Z-Score is
calculated by subtracting the mean from the subject score and dividing by the standard deviation,
thus:
z ൌ ሺx െ xbarሻ/ሺsሻ
The Z-Score is a number that reveals how many standard deviations a score is from the mean of the
scores.
For example, using a Daily Individual Alarm Rate of 34 (x) unresolved alarms per hour, Weekly
Individual Alarm Rate Mean (xbar) of 28.7 and a Weekly Individual Alarm Rate Standard Deviation
(s) of 8.9, the associated Z-Score is:
z = (34 – 28.7) / 8.9 = 0.60 (rounded),
This indicates that the daily rate is within 0.60 standard deviations from the mean for this sensor,
based on the sensor’s historical performance.
Assuming that a sensor is functioning according to a normal distribution of performance variation
(only random variation in its performance), scores that produce (-2 < Z-Score < 2) are considered
normal (or, expected) for this sensor. Generally, analysts should expect a larger amount of data to
produce a mean and standard deviation representing more accurate performance of the sensor.
Analysts should calculate baseline means and standard deviations each week for each sensor, using all
of the previous weekly data scores. Using these values, analysts should calculate a Z-Score for any
individual daily or weekly alarm rate and determine whether the sensor is deviating from normal
performance with statistical significance. Analysts should evaluate scores with the Z-Score method
to determine whether there are an excessive number of alarms that could degrade system operator
responsiveness.
Section 26
Analysts should remove from calculations scores for which extreme outlying results to avoid skewing
results if a firm cause for the outliers is determined and remedied. This is a quantitative scale as
identified in Table 7.13, Z-Score Scale, below. As discussed above, each sensor should have a
separate rating for causal analysis and corrective action. Comparing sensors of the same style may
also highlight a poorer performing sensor rather than reviewing the individual sensors score.
25
DOE STD-1219-2016
However, for the Z-Score, analysts should generate a total value for the system to average the
characteristic score. The Z-Score is part of the system scale.
Table 7.13 Z-Score Scale
Z-Score
Scale Description
1 -3 < Z-Score < 3
2 -2.5 < Z-Score < 2.5
3 -2 < Z-Score < 2
4 -1.5 < Z-Score < 1.5
5 -1 < Z-Score < 1
8. EXAMPLE ANALYSIS
The example provided below only covers the scale rating and matrix presentation. For a complete
analysis report, analysts should submit narrative describing the assessment process for each characteristic
rated highlighting the reasoning leading to the characteristic rating.
After much analysis by various subject matter experts, a site protecting Category I SNM has completed
their analysis of the IDS characteristics. Their scores along with the average rating of each scale is
presented below in Table 8.1, System Scale and 8.2, Operator Scale.
Table 8.1 System Scale
System
Scale Description
3 Alarm Frequency
2 Ergonomics
3 Maintenance Rate and Repairability
3 Performance Testing Alarm Rate
3.5 System Interface (Considered a minor characteristic for this example)
3 Technical Knowledge
4 Testing Frequency
3 Z-Score
Average 3.1
Table 8.2 Operator Scale
Operator
Scale Description
3 Ancillary Duties
4.5 Average Alarm Acknowledgement Time (Considered a major characteristic for this
example)
2 Operator Performance Test
4 Oversight
2 Training Test Scores
Average 3.1
26
DOE STD-1219-2016
Charting these scale results on Figure 8.1, Example Analysis Matrix, identifies that the system falls
slightly above the horizontal centerline between sectors II and I and with slightly above average system
health.
III I
IV II
System Scale
O
p
er
at
o
r
Sc
al
e
1 2 3 4 5
1
2
3
4
5
Figure 8.1 Example Analysis Matrix
The analyst plots the matrix point again on the overlay on Figure 8.2, Example Operability and Reliability
Matrix. This matrix identifies that although the operator and system are performing adequately for an
average system, the IDS is not effective for protecting vital national assets.
27
I
DOE STD-1219-2016
III
IV II
System Scale
O
p
er
at
o
r
Sc
al
e
1 2 3 4 5
1
2
3
4
5
Figure 8.2 Example Operability and Reliability Matrix
The primary analyst should report the results and the responsible security authorities should identify the
lowest performing characteristics and address the shortcomings. In this example, both the operator and
system have characteristics that the responsible security authorities should address to ensure the IDS is
operating effectively.
Section 27
9. CHARACTERISTIC WEIGHTING
To account for some characteristics having more or less impact on the operability and reliability of the
IDS, Table 9.1, Weighted Average Effect, presents weighted scoring scales. Analysts may apply these
identifiers to tailor the scoring values of specific characteristics. If weighted characteristics are used, the
responsible security authority and analysts should identify the major and minor characteristics prior to
final scoring. Analysts shall capture the decision to rate a characteristic as major or minor along with
supporting information within the report.
Table 9.1 Weighted Average Effect
Major
characteristic
scale
Designator Average
characteristic
scale
Designator Minor
characteristic
scale
0.5 Poor 1 Poor 1.5
1.5 Moderate 2 Moderate 2.5
3 Fair 3 Fair 3
4.5 Good 4 Good 3.5
5.5 Excellent 5 Excellent 4.5
Weighting the characteristic works as the system and operator scales are an average. The larger or
smaller the range of the score numbers the more or less impact to the average. Table 9.2, Weighted
Average Example One, below provides an example of the effect of weighting on an average.
28
DOE STD-1219-2016
Table 9.2 Weighted Average Example One
Characteristic Average scores, not weighted Weighted Scores
Ergonomics
(Minor Characteristic)
5 4.5
Alarm Frequency
(Major Characteristic)
1 0.5
Scale Results (Average) 3 2.5
As provided in Table 9.2 above, if a characteristic is identified as minor and is operating well above
expected levels rather than receiving a 5 score it should receive a 4.5, reducing the impact of the
characteristic when computing the average. By contrast, a major characteristic operating well below
expected levels should receive a 0.5 score rather than a 1, increasing the impact to the average. Table 9.3,
Weight Average Example Two, below shows the impact of the results in reverse and further highlights
how a major characteristic score overrides a minor characteristic score.
Table 9.3 Weighted Average Example Two
Characteristic Average scores, not weighted Weighted Scores
Ergonomics
(Minor Characteristic)
1 1.5
Alarm Frequency
(Major Characteristic)
5 5.5
Scale Results (Average) 3 4.3
Table 9.4, Operator Scale Weighted Average Example, reveals the impact of weighted average over an
entire scale.
Table 9.4 Operator Scale Weighted Average Example
Characteristic Scores not weighted Weighted Scores
Ancillary Duties 3 3
Average Alarm
Acknowledgement Time
3 3
Operator Performance Test
(Major Characteristic)
1 0.5
Oversight
(Minor characteristic)
5 4.5
Training Test Scores 4 4
Scale Results (Average) 3.2 3
The example in Table 9.4 above highlights how the operator performance test characteristic identified as a
major characteristic assigned a low score pulls down the average. This weighted characteristic with a
lower score overpowers the excellent scoring oversight characteristic identified as a minor characteristic
when calculating the average. Analysts should use the weighted characteristic sparingly and have
documentation supporting the decision. The intent of using a weighted characteristic is to ensure less
important characteristics performing well, do not hide the impact of an important characteristic
performing poorly.
29
DOE STD-1219-2016
Common major characteristics likely include alarm frequency, performance testing alarm rate, Z-score,
and average alarm acknowledgement time. Common minor characteristics likely include ergonomics,
operator performance test, and training test scores.
Section 28
10.ROOT CAUSE IDENTIFICATION
Correcting the immediate cause of a problem may provide a temporary improvement to the issue.
However, to ensure the characteristic operates as necessary requires correcting the root cause of the
problem. Identifying and correcting this base cause requires a methodical analysis and corrective action
process. As part of the quality assurance and assessment programs, sites shall have an established process
of causal analysis and corrective action. This technical standard will not define causal analysis and
corrective action processes, but rather identifies probable topics influencing the characteristic. As stated
above the more granular the initial analysis the easier the cause identification and correction.. .
10.1. Alarm Frequency
Installation and maintenance are the primary cause of unacceptable levels of alarm frequency.
Installing the wrong type of sensor will allow environmental or biological activities to have a greater
impact. Maintenance adjustments to sensor position and settings may also affect detection and alarm
rates. The best methods to identify these issues are through assessment, observation, interviews, and
performance testing.
10.2. Ancillary Duties
Resources and requirements affect the number and type of ancillary duties. The amount of staffing
resources controls the number of operators and training opportunities. Additionally, the talent and
skill level of the operator can hide or highlight the impact of the additional duties. Conducting
assessments and interviews identifies the cause and correction of ancillary duties problems.
10.3. Average Alarm Acknowledgement Time
Causes of unacceptable acknowledgement times include training and experience of the operator,
difficulty in systems operations, the number and difficulty of ancillary duties, the number of systems
requiring operation, and the system engineering (e.g., failed to engineer to address external effects
such as the environment or animals). In addition, Analysts should review the categorization time to
ensure that the operator is not frequently categorizing the alarm within a second of acknowledging the
alarm generally indicating an inattentive operator. Analysts can conduct causal analysis through
assessments, observations, and interviews.
10.4. Ergonomics
The impact of ergonomics begins with the initial installation and changes as authorities add systems
and make changes. Analysts should identify causes and corrections through observation of the
facility and employ trained safety professionals as subject matter experts to conduct reviews as
necessary.
10.5. Operator Performance Tests
Analysts should review testing frequency and types of testing when addressing causal analysis for
operator performance tests. In addition, the analysts should also review the experience of the
operators and the history of testing program as new programs and new operators could affect the
outcome of testing. Analysts can collect this data through assessment, observation of testing
activities, interviews with performance testing personnel and operators, and document review of
testing records.
30
DOE STD-1219-2016
Section 29
10.6. Maintenance Rate and Repairability
Planning and installation are initial factors to the causes of a poorly scoring maintenance
characteristic. A properly planned and installed system should require limited maintenance beyond
planned maintenance of cleaning and inspection. Changing system requirements make problems in
this topic worse. Naturally, older systems will commonly have more maintenance issues as they
mature. The truly concerning problem is a brand new system that requires maintenance beyond the
installation and break in time. Analysts should review documentation, diagrams, and maintenance
records as the first steps to identifying cause. Included in this document review should be observation
of maintenance efforts and interviews with the technicians completing repairs. Maintenance impact
can also be influenced by the experience and training of the technician. Concerning repairability
aspects, more than just a measure between the installation date and the current date, the repairability
aspect also rates the impact of parts and the difficulties in maintaining the system. In addition to
noting the installation date, analysts should review the availability and costs of repair parts and
materials. Other sources of information include the technicians who understand the resources and
limitations. Interviews and document reviews should identify concerns and corrections in this
characteristic
10.7. Oversight
Analyst can identify sources of causal analysis and corrective action within training, talent,
experience, and system exposure. Management’s initial response to most security issues is to require
more attention by leadership. This may fix the problem initially and provide the operator time to
increase their talent and experience to mitigate the actual concern. Analysts should be aware that a
lower score on the oversight characteristic could be a short-term corrective action of other issues.
Analysts will have to review system alarm rates, training records, testing results, and system
characteristics to identify whether or not the addition of the supervisor is actually a mitigating factor.
Observations, interviews, and document reviews should provide data to identify the cause and
correction.
10.8. Performance Testing Alarm Rate
Installation and maintenance are the primary causes of unacceptable testing alarm rate frequencies.
As systems expand and provide more multilayered coverage, the frequency of alarms will likely
increase. Testing events will provide data for causal analysis and corrective action. Analysts should
also review security response plans as responding forces moving through detection zones are also
likely to increase alarm rates. As discussed in the characteristic section any review of alarm rates
should reference the adversary attack plan as different pathways may produce different levels of
alarm.
10.9. System Interface
Analysts should begin causal analysis and corrective action of system interface through review of
installation and maintenance documentation. Analysts should review historic documents and
complete interviews with operators and technicians to identify the cause and corrective action.
Interviews are important to this topic as they provide insight to operations and the limitations based
on manufacturing and engineering requirements.
Section 30
10.10. Technical Knowledge
A system with basic technical requirements purchased off the shelf from a known open source
provider can be part of an initial purchase and evolve into a very specialized system. For causal
analysis purposes, analysts should review the initial installation and interview operators and
technicians to identify if this system is historically difficult to maintain or if an evolution changed the
original design. As with all analysis, documentation review is vital to identify if technical
31
DOE STD-1219-2016
specialization is necessary or a product of resource constraints. Other data for the analyst to review
includes the training provided from the system manufacturer.
10.11. Testing Frequency
Interviews and document review concerning testing protocols and company interfaces should define
testing levels. Testing can be limited to a few organizations for a number of reasons. This
characteristic is an administrative or resource issue and can highlight lack of communication and
coordination between organizations.
10.12. Training Test Scores
Analysts should review documentation on training including training records, lesson plans, and
instructor’s reports to identify any trends. Analysts should be aware, however, that not all
weaknesses in training scores point back to the training organization. Analysts can also identify
impacts to training in the time and exposure of the operator to the system. As with all topics,
influences such as mission, resources, management, administrative controls, or resources may have an
effect on the scores of the operator.
10.13. Z-Score
Very similar to the alarm frequency characteristic from which this statistic is derived, the installation
and maintenance of the sensor affects sensor functionality and sensitivity. In addition, the age of the
sensor may have an effect as the capabilities may degrade with time. Analysts should follow the
same path as addressing the alarm frequency and review the same source of information to address
the concerns of this characteristic.
32
CONCLUDING MATERIAL
Review Activity Preparing Activity
EM Office of Security Policy (AU-51)
Policy (AU-51)
EHSS
MA
NE
NNSA
SC
EA
Field, Site and Operations Offices Project Number
ID P2015-03
NNSA Service Center
ORO
RL
SRO
INL
LASO
LLSO
NSO
OR
RLSO
SRSO
SSO
NPO
External Agency
N/A
33
Structure Bookmarks
Annot
Annot
Annot
Annot
Annot
Annot
Annot
Annot
Annot
Annot
Annot
Annot
Annot
Annot
Annot