DOE-HDBK-1122-99 Module 2.07, Fundamental Academic Training Instructor's Guide Phase I; Module 2.07, Study Guide - Respiratory Protection
Functional areas: Radiological Control, Technician Training, Study Guide, Respiratory Protection
DOE Order 440.1 mandates the requirements for a respiratory protection program contained in 29 CFR 1910.134 and ANSI Z88.2.
Unknown Block text
Document text
Text extracted from the attached file. Refer to the original document for the authoritative version.
Section 1
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-1
Course Title: Radiological Control Technician
Module Title: Respiratory Protection
Module Number: 2.07
Objectives:
2.07.01 Explain the purpose of respiratory protection standards and regulations.
2.07.02 Identify the OSHA, ANSI, and DOE respiratory protection program
requirements.
2.07.03 Identify the standards which regulate respiratory protection.
2.07.04 Describe the advantages and disadvantages (limitations) of each of the
following respirators:
a. Air purifying, particulate removing filter respirators
b. Air purifying, Chemical Cartridge and Canister respirators for Gases and
Vapors
c. Full-face, supplied-air respirators
d. Self-contained breathing apparatus (SCBA)
e. Combination atmosphere supplying respirators
2.07.05 Define the term protection factor (PF).
2.07.06 State the difference between a qualitative and quantitative fit test.
2.07.07 State the recommended physical functions the subject must perform during a
respirator fit test.
2.07.08 State how the term protection factor (PF) is applied to the selection of
respiratory protection equipment.
2.07.09 State the general considerations and considerations for the nature of the hazard
when selecting the proper respiratory protection equipment.
i 2.07.10 Identify the types of respiratory equipment available for use at your site.
2.07.11 Identify the quality specification breathing air must meet.
References:
1. "Basic Radiation Protection Technology", Gollnick, D., Pacific Radiation
corporation, Altadena, 2nd edition.
2. "Radiation Protection", General Physics Corporation, 1989.
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-2
3. "Introduction Health Physics", Second Edition, Cember, H., Pergamon Press,
London, 1983.
4. "Limits for Inhalation of Radon Daughters by Workers", ICRP Publication 32.
5. "Limits for Intakes of Radionuclides by Workers", ICRP Publication 30.
6. "Operational Health Physics Training Course", Moe, H.J., et. al., Argonne
National Laboratory, Argonne, 88-26.
7. "Radiation Detection and Measurement", Knoll, G., John Wiley and Sons, New
York, 1979.
8. "Practices of Respiratory Protection", ANSI Z88.2, 1992.
9. "Manual of Respiratory Protection Against Airborne Radioactive
Material",NUREG-0041, 1976.
10. Respiratory Protection, Federal OSHA, 29 CFR 1910, 134.
11. OSHA 29 CFR 1910. 134
12. ANSI Z88.2-1992
13. CGA G7.1-1989
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-3
2.07.01 Explain the purpose of respiratory protection standards and regulations.
2.07.02 Identify the OSHA, ANSI, and DOE respiratory protection program
requirements.
2.07.03 Identify the standards which regulate respiratory protection.
OSHA AND DOE REQUIREMENTS
DOE Order 440.1 mandates the requirements for a respiratory protection program
contained in 29 CFR 1910.134 and ANSI Z88.2.
The Occupational Safety and Health Standard, 29 CFR, Part 1910.134, specifies the
minimal acceptable respiratory protection program must contain or address the following:
• Written standard operating procedures governing the selection and use of
respirators shall be established.
• Respirators shall be selected on the basis of hazards to which the worker is
exposed.
• The user shall be instructed and trained in the proper use of respirators and their
limitations.
Section 2
• Respirators shall be regularly cleaned and disinfected. Those issued for the
exclusive use of one worker should be cleaned after each day's use, or more often
if necessary. Those used by more than one worker shall be thoroughly cleaned
and disinfected after each use.
• Respirators shall be stored in a convenient, clean, and sanitary location.
• Respirators used routinely shall be inspected during cleaning. Worn or
deteriorated parts shall be replaced. Respirators for emergency use such as self-
contained devices shall be thoroughly inspected at least once a month and after
each use.
• Appropriate surveillance of worker area conditions and degree of employee
exposure or stress shall be maintained.
• There shall be regular inspection and evaluation to determine the continued
effectiveness of the program.
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-4
• Persons should not be assigned to tasks requiring use of respirators unless it has
been determined that they are physically able to perform the work and use the
equipment. The local physician shall determine what health and physical
conditions are pertinent. The respirator user's medical status should be reviewed
periodically (for instance, annually).
• Approved or accepted respirators shall be used when they are available. The
respirator furnished shall provide adequate respiratory protection against the
particular hazard for which it is designed in accordance with standards established
by competent authorities.
These "Ten Commandments" form the basis for any occupational safety respiratory
protection program. ANSI Z88.2-1992 further specifies the minimal acceptable program
for industries involved in the use of radioactive material, and addresses the following:
• Individual exposures limited by both inhalation and skin absorption
• Air sampling and bioassays
• Engineering controls as the primary method
• Individuals exposed to greater than the specified DAC or other exposure limits
• Respiratory protection equipment certifications (NIOSH/MSHA)
If allowance for the use of respiratory protection equipment in estimating exposures is
made, then the following must be observed:
• The protection factor for the device selected must be greater than the ratio of the
peak exposure concentration and the associated DAC or other exposure limit.
• The average concentration inhaled on any one day must be less than the associated
DAC.
• If the exposure is later found to be greater than estimated, the corrected value shall
be used, if less than estimated, the corrected value may be used.
• Surveys and bioassays conducted as appropriate to evaluate actual exposures.
• Written procedures for selection, fitting, maintenance, records, issuance and pre-
use operability checks of respirators, and supervision and training of personnel
using respirators must be established.
• Prior to initial use and annually, determination by a qualified health care
professional of a user's physical capability to wear a respirator must be performed.
• A written policy statement on use of engineering controls instead of respirators;
routine, non-routine, and emergency use of respirators; and periods of respirator
use and relief from respirator use must be issued.
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-5
2.07.04 Describe the advantages and disadvantages (limitations) of each of the
following respirators:
a. Air purifying, particulate removing filter respirators
Section 3
• Each user must be advised that they can leave the work area upon failure of
equipment, physical distress or deterioration of operating conditions.
• Equipment is to be used for appropriate environment and special equipment such
as visual or communication devices are to be issued when needed.
• Emergency use equipment must be specifically certified as such by
NIOSH/MSHA.
RESPIRATORY PROTECTION EQUIPMENT
Air Purifying, Particulate-Removing Filter Respirators
Description:
These are often called "dust," "mist," or "fume" respirators and by a filtering action
remove particulates before they can be inhaled. Single use, quarter mask, half mask, full
facepiece, and air powered hood/mask are the five types of respirators that work by the
particulate removal method. Air purifying respirators generally operate in the negative
pressure (NP) mode; that is, a negative pressure is created in the facepiece during
inhalation. An exception is a special type of powered air purifying respirator that
operates by using a motor-driven blower to drive the contaminated air through an air
purifying filter or sorbent canister.
Limitations:
Air purifying respirators do not provide oxygen, so they must NEVER be worn in
oxygen-deficient atmospheres.
Particulate-removing air-purifying respirators offer no protection against atmospheres
containing contaminant gases or vapors.
Except for pressurized air purifier respirators, these respirator types should not be used
for abrasive blasting operations.
Battery operated air powered respirators are limited by battery life which may be
unknowingly shortened due to a memory build-up on the rechargeable NiCd batteries.
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-6
2.07.04 Describe the advantages and disadvantages (limitations) of each of the
following respirators:
b. Air purifying, Chemical Cartridge and Canister respirators for
Gases and Vapors
2.07.04 Describe the advantages and disadvantages (limitations) of each
of the following respirators:
c. Full-face, supplied-air respirator
High humidity may increase breathing resistance as paper elements become water
saturated.
Air Purifying, Chemical Cartridge and Canister Respirators for Gases and Vapors
Description:
Vapor and gas-removing respirators use cartridges or canisters containing chemicals (i.e.,
sorbents) to trap or react with specific vapors and gases and remove them from the air
breathed. The basic difference between a cartridge and a canister is the volume of the
sorbent.
Limitations:
These respirators do not provide oxygen, so they must NEVER be worn in oxygen
deficient atmospheres.
Unless specifically approved by DOE, no credit may be taken for the use of sorbent
cartridges or canisters for protection against radioactive gases and vapors.
High humidity environments may shorten the life of the sorbent material.
Atmosphere Supplying Respirators - Supplied Air
Description:
Supplied air respirators use a central source of breathing air that is delivered to the wearer
through an air supply line or hose. The respirator type is either a tight-fitting facepiece
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-7
(half face or full) or loose-fitting hood/suit. There are essentially two major groups of
supplied air respirators - the air-line device and the hose mask with or without a blower.
Hose masks are not used in power reactors; consequently, further discussion will be
limited to demand, pressure demand, and continuous flow air line respirators.
Section 4
In a demand device, the air enters the facepiece only on "demand" of the wearer, i.e.,
when the person inhales. During inhalation, there is a negative pressure in the mask, so if
there is leakage, contaminated air may enter the mask and be inhaled by the wearer. For
this reason, demand respirators are generally no longer used. The pressure demand
device has a regulator and valve design such that there is a flow (until a fixed static
pressure is attained) of air into the facepiece at all times, regardless of the "demand" of
the user. The airflow into the mask creates a positive pressure. The continuous-flow air
line respirator maintains a constant airflow at all times and does not use a regulator, but
uses an airflow control valve or orifice which regulates the flow of air. The continuous-
flow device does not guarantee a positive pressure in the facepiece.
Limitations:
Since the air line respirator provides no protection if the air supply fails, they shall not be
used in IDLH atmospheres or for emergency escape or rescue.
The trailing air supply hose severely limits mobility so it may be unsuitable if frequent
movement among separated work stations is required.
The length of hose, number of potential users, and pressure of the supply system can
reduce the number of allowable users.
Control of the air quality is essential to avoid introduction of hazardous respiratory agents
to the wearers breathing zone.
"Bubble suits" can aspirate air into the suit when the wearer lifts his arms. Consequently,
the suit must be tested for the exact conditions of use.
Special Considerations:
In a situation where the air line respirator is a suit, there shall be a standby rescue person
equipped with self contained breathing apparatus and communications equipment
whenever supplied-air suits are used.
Requirements for use of respirators in "dangerous" atmospheres is specified in 29 CFR
1910.134(e)(3) as follows:
"(3) Written procedures shall be prepared covering safe use of respirators in
dangerous atmospheres that might be encountered in normal operations or in
emergencies. Personnel shall be familiar with these procedures and the available
respirators.
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-8
(i) In areas where the wearer, with failure of the respirator, could be overcome by
a toxic or oxygen-deficient atmosphere, at least one additional man shall be
present. Communications (visual, voice, or signal line) shall be maintained
between both or all individuals present. Planning shall be such that one individual
will be unaffected by any likely incident and have the proper rescue equipment to
be able to assist the other(s) in case of emergency.
(ii) When self-contained breathing apparatus or hose masks with flowers are used
in atmospheres immediately dangerous to life or health, standby men must be
present with suitable rescue equipment.
(iii) Persons using air line respirators in atmospheres immediately hazardous to
life or health shall be equipped with safety harnesses and safety lines for lifting or
removing persons from hazardous atmospheres or other equivalent provisions for
the rescue of persons from hazardous atmospheres shall be used. A standby man
or men with suitable self-contained breathing apparatus shall be at the nearest
fresh air base for emergency rescue."
Section 5
Manufacturers of airline respirators include instructions specifying a range of air required
to produce at least the minimum required flow rates (4 CFM for tight fitting facepiece and
6 CFM for hoods). These specifications are based on hose lengths and the number of
sections connected together. Determining if the proper air flow rate is achieved can be
complicated by the use of a breathing air manifold supplying more than one user. The
following are recommendations which should be considered.
If all the hose lengths and number of hose fittings are the same, then a manifold with a
single regulator and pressure gauge is appropriate for ensuring the proper pressure is
used. (Note: If the pressure is within the manufacturer's specifications, then the delivery
air flow rate should be at least 4 CFM for tight fitting respirators and 6 CFM for hoods).
For situations where each user has different hose lengths, different number of connection
or different air pressure requirements then a separate pressure gauge should be used as
follows:
The air flow rate should be measured at the end of the breathing tube (i.e., at the delivery
end). This air flow rate should be measured using a calibrated rotameter or equivalent air
flow measuring device.
To utilize the Protection Factor (PF) assigned to air supplied hoods, a delivery flow rate
of at least 6 CFM but not greater than 15 CFM must be obtained. The individual user's
air flow valves should not be altered to maintain a minimum delivery flow rate of 6 CFM
as this violates the NIOSH/MSHA approval. Taping or otherwise securing the airflow
valves in the fully open position does not void the NIOSH/MSHA approval provided the
valve is not permanently altered or made so that it would be impossible to increase or
decrease the air flow by the user.
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-9
2.07.04 Describe the advantages and disadvantages (limitations) of each
of the following respirators:
d. Self-contained breathing apparatus (SCBA)
Atmosphere Supplying Respirators - Self-Contained Breathing Apparatus (SCBA)
Description:
The self-contained breathing apparatus (SCBA) allows the user to carry a respirable
breathing supply does not need a stationary air source such as a compressor to provide
breathable air. The air supply may last from 3 minutes to 4 hours depending on the nature
of the device.
There are two groups of SCBAs - the closed circuit and the open circuit.
Another name for closed circuit SCBAs is "rebreathing" device. The air is rebreathed
after the exhaled carbon dioxide has been removed and the oxygen content restored by a
compressed oxygen source or an oxygen-generating solid. These devices are designed
primarily for 1-4 hours use in toxic atmospheres.
An open circuit SCBA exhausts the exhaled air to the atmosphere instead of recirculating
it. A tank of compressed air carried on the back, supplies air via a regulator to the
facepiece. Because there is no recirculation of air, the service life of the open circuit
SCBA is shorter than the closed circuit system. The only type of open circuit SCBA
available for use is “pressure demand”.
The pressure demand open circuit SCBA has a regulator and a valve design which
maintains a positive pressure in the facepiece at all times regardless of the "demand" of
the user. Because of the high degree of protection provided by the pressure-demand
SCBA, this type of unit is recommended for emergency use, escape and rescue. There
also exist combination atmosphere supplying respirators which utilize supplied air and an
SCBA.
Section 6
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-10
2.07.04 Describe the advantages and disadvantages (limitations) of each
of the following respirators:
e. Combination atmosphere supplying respirators.
Combination Atmosphere Supplying Respirators
Two types of combination supplying respirators are the combination pressure demand
breathing apparatus and the dual purpose breathing apparatus. The combination pressure
demand breathing apparatus provides respiratory protection for personnel who must work
in atmospheres that are immediately dangerous to life or health (IDLH). When connected
to a respirable air source, the device permits the wearer to work and move about freely,
within the limits of the approved hose length. The combination pressure demand
breathing apparatus is equipped with a small air cylinder which enables the wearer to
escape from dangerous atmospheres in case the primary air supply is interrupted.
The apparatus serves as a long duration work device and as an escape device as well. It is
approved for respiratory protection for entry into, for extended periods of work in, and for
escape from IDLH atmospheres. If used for entry into IDLH atmospheres, the air line
must be connected before entry. The self-contained air supply is approved for escape
only.
Operation of the combination pressure demand breathing apparatus is manual. It is an
approved, rated 5-minute escape device. The pressure demand air line respirator phase is
connected by an approved air-supply hose to a primary respirable air source; the worker
breathes from this source with the valve of the egress (exit) cylinder of the device turned
off until the user is ready to leave the working area. If the primary air supply source
should fail for any reason, the worker can switch to the egress cylinder by turning a valve
and escape to a safe atmosphere. The worker then can leave, connected to the primary air
source, or can open the egress cylinder valve and have approximately five minutes'
respiratory protection. When breathing from the air cylinder, the user can remain
connected to the primary air supply and exit, or can disconnect from the air source for
easier escape.
The dual purpose breathing apparatus combines all the capabilities of a self-contained
breathing apparatus and a supplied-air respirator in one unit. The apparatus is approved
by the NIOSH and MSHA for use in oxygen deficient atmospheres or where dangerous
concentrations of toxic gases or vapors are present. The NIOSH/MSHA approval allows:
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-11
• The wearer of the apparatus to enter or exit a dangerous area using only the
cylinder air in applications such as emergency rescue
• The wearer to work within the area for a limited time using the cylinder air
• The wearer to work within the area for an extended time using air from a supply
line.
Thus, the dual purpose breathing apparatus has all the advantages of both air and work
masks. Note particularly that 20% of the cylinder air may be used for entry and that the
apparatus is not limited to escape. Of course, if the air from the supply line should fail,
the wearer can escape the area using the cylinder air.
Section 7
The dual purpose breathing apparatus is available in both demand and pressure demand
models. In the demand model, air is supplied on demand at ambient atmospheric
pressure. In the pressure demand model, a slight positive pressure is maintained within
the facepiece during both inhalation and exhalation. The slight positive pressure prevents
a toxic atmosphere from leaking into the facepiece; this type of leakage can occur with a
demand apparatus due to the negative pressure developed in the facepiece. A pressure
demand apparatus should therefore be used where the potential toxicity of the atmosphere
is such that no back leakage can be tolerated.
The regulator on the dual purpose breathing apparatus reduces the high pressure from the
apparatus's compressed air cylinder to a breathable pressure. In pressure demand models,
it also automatically monitors the flow of air into the facepiece so as to maintain a slight
positive pressure within the facepiece. The regulator has two inlet ports - one for the
cylinder and another for the supply line. A connector allows the air supply to be semi-
automatically switched from the cylinder to the air line. With no supply line connected to
the regulator, the wearer receives air from the cylinder. When an air line is connected to
the regulator through the fitting, the wearer automatically receives air from the supply
line. If the air supply from this line should be interrupted, the wearer must disengage the
supply line in order to automatically receive air from the cylinder.
Limitations of the Pressure Demand and Demand SCBA. The air supply is limited to
the amount in the cylinder and therefore the respirator cannot be used for extended
periods without recharging or replacing cylinders.
Because these respirators are bulky and heavy, they are often unsuitable for strenuous
work or use in confined spaces.
The demand type SCBA works in a negative pressure mode and is considered obsolete.
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-12
2.07.05 Define the term protection factor (PF).
Special Considerations of the Pressure Demand SCBA. As specified in ANSI Z88.2,
only the pressure-demand type SCBA should be selected for emergency use, rescue, and
re-entry into a contaminated area to perform emergency shutdown or maintenance of
equipment.
The performance of SCBAs in high temperature environments, such as fires may lead to
rapid deterioration of components.
PROTECTION FACTORS
The overall protection afforded by a given respirator design is defined in terms of its
protection factor (PF). The PF is defined as the ratio of the concentration of contaminant
in the atmosphere to the concentration inside the facepiece or hood under conditions of
use.
Protection Factors may not be appropriate where chemical or other respiratory hazards
exist in addition to radioactive hazards or where the mode of entry is through the skin and
not through inhalation. For example, 50% of the intake from exposure to tritiated oxide
is through skin absorption. The use of atmosphere supplying respirators will only provide
a PF of 2.
Application of PF's is relatively straight forward. The work area airborne radioactivity
concentration is divided by the PF to estimate the inhaled concentration. For example, a
worker performing steam generator eddy current testing with a full facepiece continuous
air flow air line respirator (PF = 1000) and in an atmosphere of 1 x 10-6 cCi/cc Co-60
would be estimated to inhale a concentration of 1 x 10-9 cCi/cc Co-60.
Section 8
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-13
Table 1 - Assigned Protection Factors (ANSI Z88.2-1992)
Type of Respirator
Respiratory Inlet Covering
Half mask1) Full Facepiece
Air Purifying 10 100
Atmosphere Supplying
SCBA (Demand)2) 10 100
Airline (Demand) 10 100
Type of Respirator
Respiratory Inlet Covering
Half
Mask
Full
Face
Helmet/
Hood
Loose-Fitting
Facepiece
Powered Air Purifying 50 10003) 10003) 25
Atmosphere Supplying Airline
Pressure Demand 50 1000 - -
Continuous Flow 50 1000 1000 25
Self-Contained Breathing
Apparatus
Pressure Demand
Open/Closed Circuit
- 4) - -
1) Includes 1/4 mask, disposable half masks, and half masks with elastomeric facepieces.
2) Demand SCBA shall not be used for emergency situations such as firefighting.
3) Protection factors listed are for high-efficiency filters and sorbents (cartridges and canisters). With dust
filters, an assigned protection factor of 100 is to be used due to the limitations of the filter.
4) Although positive-pressure respirators are currently regarded as providing the highest level of respiratory
protection, a limited number of recent simulated workplace studies concluded that all users may not achieve
protection factors of 10,000. Based on this limited set of data, a definitive assigned protection factor could
not be listed for positive-pressure SCBAs. For emergency planning purposes where hazardous concentrations
can be estimated, an assigned protection factor of no higher than 10,000 should be used.
NOTE: Assigned protection factors are not applicable for escape respirators. For combination
respirators, e.g., airline respirators equipped with an air-purifying filter, the mode of operation
in use will dictate the assigned protection factor to be applied.
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-14
2.07.06 State the difference between a qualitative and quantitative fit test.
2.07.07 State the recommended physical functions the subject must
perform during a respirator fit test.
RESPIRATOR FIT TESTING
Definitions:
Qualitative fit test: Test to determine if there is any mask leakage, usually
using irritant smoke ("Go/no-go" test but no measured
value is assigned).
Quantitative fit test: Test to determine quantity of mask leakage and assign a "fit
factor," corn oil is the typical challenge atmosphere used
(Measures concentration in mask due to leakage against
concentration in atmosphere).
It is impractical to perform a quantitative fit test prior to each entry requiring respiratory
protection. Therefore, qualitative tests are performed to ensure an adequate fit for the
user. Qualitative tests can use challenge atmospheres such as Isoamyl Acetate (banana
oil) or irritant smoke (e. g., stannic chloride) or as a negative or positive pressure test.
The irritant smoke test is the most effective since the wearer's obvious discomfort from
the smoke will show leakage through the respirator face seal. However, the test produces
noxious odors for not only the wearer but those in the test area. The use of "banana oil"
requires a subjective evaluation by the wearer and more often than not a user will not
admit that in-leakage has occurred. One reactor respiratory program was faithfully
utilizing the banana oil to perform the fit test and virtually all wearers indicated no in-
leakage through the facepiece. Unfortunately, the respirator only contained a particulate
filter cartridge rather than an organic vapor cartridge. Since most reactors use respirators
at many different locations, challenge atmosphere tests are difficult to perform and
therefore the "immediately prior-to-use" qualitative test normally selected is to perform a
negative pressure test.
Section 9
Additional factors to be considered in fit testing acceptance criteria are the use of
communication devices or sorbent canisters with respirators. The respirator approval is
voided if any communication device is attached to the facepiece, unless the device is
listed in the NIOSH/MSHA approval sheet.
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-15
2.07.08 State how the term protection factor (PF) is applied to selection of
respiratory protection equipment.
2.07.09 State the general considerations and considerations for the nature of the
hazard when selecting the proper respiratory protection equipment.
In addition to fit testing personnel, the respirator face pieces and cartridges must be
periodically tested. Common practices are to test a portion of particulate cartridges upon
procurement and to test all particulate cartridges prior to re-use. Anytime the filter is
used by a different individual or on a different day by the same individual, the filter is
considered as being reused and should be tested for efficiency, resistance and radioactive
contaminants. As long as the inhalation valve for the respirator is in place and functions
normally, concern for biological contaminants is of the filter is minimal.
The subject performs at least the following functions during fit testing:
1) Normal breathing
2) Deep breathing
3) Moving head from side to side
4) Moving head up and down
5) Frown
6) Talking
7) Running in place
8) Normal breathing
SELECTION
In protecting against radiological airborne contaminants the most critical factor will be
meeting the provisions of ANSI Z88.2 which requires the protection factor for the
respirator device used to be greater than the ratio of the work area airborne concentration.
Equipment selected must be certified by NIOSH/MSHA or specifically authorized by
DOE. Approvals for respiratory devices are authorized in accordance with 42 CFR 84
and the device, type and certification number are listed in NIOSH publication entitled,
Certified Equipment List.
Selection of the proper respirator for any given situation shall require consideration of the
following:
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-16
• The nature of the hazard
• The characteristics of the hazardous operation or process
• The location of the hazardous area with respect to a safe area having respirable air
• The period of time for which respiratory protection may be provided
• The activity of the workers in the hazardous area
• The physical characteristics, functional capabilities, and limitations of respirators
of various types
• The respirator-protection factors and respirator fit
The following factors concerning the nature of the hazard requiring the use of respirators
shall be considered in respirator selection:
• The type of hazard
- Oxygen deficiency
- Contaminant
• The physical and chemical properties
• The physiological effects on the body
• The peak and average concentrations of toxic material or airborne radioactivity
level
• The established permissible time-weighted average or peak concentration of toxic
material, or both, or established maximum permissible airborne radioactivity level
for radioactive substances
• Whether the hazard is an immediately-dangerous-to-life-or-health concentration
of toxic material
• Warning properties
Section 10
Recognition and evaluation of the respiratory hazard (oxygen deficiency or
contaminant(s)) shall be an essential part of selecting a respirator except in emergency or
rescue operations. Initial monitoring of the respiratory hazard shall be carried out to
obtain data needed for the selection of proper respiratory protection. The data should
include:
• Identification of the type of respiratory hazard
- Oxygen deficiency
- Specific contaminants
• Nature of contaminants
- Particulate matter
- Vapors or Gases
• Concentration of respiratory hazard
The following factors concerning the hazardous operation or process shall be taken into
account in selecting the proper respirator:
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-17
2.07.10 Identify the types of respiratory equipment available for use at your site.
2.07.11 Identify the quality specifications breathing air must meet.
• Operation, process, and work-area characteristics
• Materials, including raw materials, end products, and byproducts (actual and
potential)
• Worker activities (Modification in the operation or process shall be taken into
account, since this may change the hazard and hence require the selection of a
different respirator.)
Selection of air-line respirators includes not only the PF but also the air supply pressure,
the air flow to the user and hose length. Each manufacturer's approval sheet lists the
approved criteria. For use of 15 to 50 ft of hose at 16 to 20 pounds per square inch, an
airflow of greater than 4 CFM to a facepiece, 6 CFM to a hood, and less than 15 CFM to
either must be obtained. As discussed, air flow rate delivery should be evaluated for
multiple personnel use of breathing air manifolds.
SITE RESPIRATORY EQUIPMENT
(Insert site specific material here)
AIR QUALITY TESTING
An air quality testing program for all sources of respirable air is required. Compressed
breathing air shall meet at least the quality specification for Grade D breathing air as
described in Compressed Gas Association Commodity Specification G-7.1-1989.
Section 5 of G-7.1 provides acceptable analytical procedures for measuring the respirable
air components. Oxygen is easily measured using standard oxygen detectors which
utilize an electrolytic reaction to generate a current proportional to the oxygen content.
However, a number of reactors perform the measurement incorrectly as the oxygen
percentage is determined by the partial pressures of the oxygen in the monitored
atmosphere versus the calibrated atmosphere. The test is often performed by placing the
detector probe directly in line with the pressurized supply line. Since the air is measured
at an increased pressure, the partial pressure will appear greater relative to the calibration
partial pressure and an overestimate of the oxygen concentration will result. A better
method is to sample the oxygen in a plastic bag and then insert the probe and withdraw
the air at a reduced pressure condition. Carbon dioxide and carbon monoxide are easily
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-18
evaluated using either in line continuous monitors or grab sample "indicator tubes". The
method at your facility will be determined by the designated Respirator Program
Administrator.
Section 11
The test for condensed hydrocarbons is usually performed by filtering the air, weighing
the filter and calculating the concentration by assuming the additional filter weight is due
to condensed hydrocarbons. For service air systems, the air quality tests should also
include monitoring for radioactive contaminants. The test for radioactive contaminants is
necessary as a number of service air and breathing air systems have been cross
contaminated from radioactive waste or auxiliary boiler contaminants.
The frequency of performing air quality tests is not specified by regulation or in
standards. For bottled air systems, such as SCBAs or respirator air supply cylinders, the
tests should be performed on a representative sample of the bottles upon receipt at the
facility. For facilities which compress respirable air and fill their own SCBAs, the
sampling should be performed prior to each lot fill, once during the lot fill and once upon
completion of the lot fill. For compressed air supply systems such as fixed station
breathing air systems the sampling frequency is best performed prior to each use of a
specific manifold system. However, this may be impractical during a major refueling
outage where supplied respirable air is extensively used at different stations. In cases of
heavy usage, then a daily check of the system may be more appropriate.
SORBENTS AND PROTECTION AGAINST RADIOIODINES
The regulations specifically prohibit the use of PFs for canister sorbents as protection
against radioiodine atmospheres. The efficiency of the charcoal canister is dependent
upon the chemical form of the radioiodine, humidity of the atmosphere, and breathing
rate of the user. Approval can be obtained from DOE to use PFs for sorbent cartridges.
A criteria for testing and certifying the charcoal cartridges is contained in NUREG/CR-
3403, "Criteria and Test Methods for Certifying Air-Purifying Respirator Cartridges and
Canisters Against Radioiodine." A brief summary of test conditions and acceptance
criteria are as follows in Table 2:
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-19
Table 2 - Test Conditions and Acceptance Criteria
Test Parameter Criteria
Vapor CH3I
Concentration 1 ppm
Temperature 30 + 1 C
Total Airflow 64 L/min
Equilibration All as received
(6H at 64 L/min) 3 at 50% RH
3 at 75% RH
Maximum Penetration .01 PPM
Minimum Service Life 30 min at 100% RH (extrapolated) 60 min at
75% RH
Limiting conditions of use:
Total challenge in the work place (radioactive iodine, non-radioactive iodine or the
halogenated compounds) may not exceed 1 ppm.
Temperature in the work area may not exceed 100 bF. Temperature to be measured on
each shift or in conjunction with operations which produce heat in the work area.
Respirator wearers must have demonstrated a fit factor greater than 100 on the full
facepiece respirator type to which the GMR-1 is attached.
Service life is 8 hours maximum. This is calculated from the time the canister is unsealed
and includes periods of non-use. Once the screw cap on the canister threads or the tape
seal over the inlet port on the bottom are removed, the 8 hour use duration begins whether
used or not by an individual.
Canisters will not be used in the presence of organic solvents, vapors, or chemicals (such
as decontamination compounds, lubricants, volatilized paint, alcohol, freon) which could
cause aging, poisoning or desorption of the adsorbed radioiodines. Non-exposure to these
organic agents must be demonstrated by usage restrictions and by air sampling.
Section 12
Canisters must be stored in sealed humidity-barrier packaging in a cool, dry environment
(QA Class "A" storage).
DOE-HDBK-1122-99
Module 2.07 Respiratory Protection Study Guide
2.07-20
COMMUNICATIONS
Although conventional respirators distort the human voice to some extent, adequate
communication can be maintained in relatively quiet areas. For power reactors, those
areas requiring the greatest use of respiratory protection are often the noisiest due to the
numerous pumps, motors and fans. Consequently, special attachments or modifications
to the respiratory device are often needed to ensure adequate communication.
A mechanical speech-transmission device, called a speaking diaphragm, is an integral
part of the facepiece in some respirators. It usually consists of a resonant cavity and
diaphragm which transmit sound. The diaphragm also acts as a barrier to the ambient
atmosphere and thus should be handled carefully to prevent possible puncture which
would permit leakage of an air contaminant into the respirator. Various methods of
electronically transmitting and amplifying speech through the respirator are available.
These utilize a microphone connected to a speaker, telephone, or radio transmitter.
Usually, the microphone is mounted inside the respiratory-inlet covering, while the
amplifier, power pack, and speaker or transmitter are attached to the exterior of the
respiratory-inlet covering, carried on the body, or remotely located. Respirators with
electronic speech-transmission devices having a battery power supply should be used
with caution in explosive atmospheres. Sealed power sources shall be checked for
integrity of the seals. Connecting cables from the microphones inside the respiratory inlet
covering shall have gas-tight seals where they pass through the covering. When the
speaker diaphragm is part of the barrier between the respirator wearer and the ambient
atmosphere, it shall be and should be adequately protected from puncture or rupture. A
microphone mounted on the respirator wearer's throat or head or a microphone/speaker
worn in the respirator wearer's ear does not require penetration of a respirator facepiece
by a cable.
Any communication device that is an integral part of the respirator or is attached to the
exterior such as a sound transducer on the face plate, must be part of the NIOSH/MSHA
approval for the respiratory device.
SUMMARY
All respiratory protection devices share a common limitation for protection against
hazardous substances which injure the skin or eyes (except SCBAs) or are absorbed
through the skin. When selecting any protective device, the chemical form of the
hazardous substance should be ascertained to determine if skin protection is required and
if the eye protection afforded by the respirator is adequate.
Module Number: 2.07